Louroe AP-16TB-RM Installation And Operating Instructions Manual

AP-16TB-RM
®
6955 VALJEAN AVE, VAN NUYS, CA 91406
PH: (818)994-6498 / FAX: (818)994-6458
/ www.louroe.comtechsupport@louroe.com
INSTALLATION AND OPERATING INSTRUCTIONS
INTRODUCTION
The AP-16TB-RM is a sixteen zone rack mounted audio base station with 2-way talk/listen capabilities. It contains a built­in microphone and speaker for two-way audio communication to the remote station. Unit has volume adjustments for both talk and listen. Zone audio can be activated by manually pressing the zone activation switches of the unit. Provides 16 line level RCA outputs for recording remote microphone audio to DVRs with multiple audio inputs. Selectable Audio output and input from a recorder are provided through RCA connectors at the rear of the unit. Has built-in speaker for listening to live audio. Compatible with all Louroe’s two-way remote speaker/microphone units. Compatible with Louroe Speaker/Microphone Models TLI, TLO, TLMC, TLM
8 ZONE AUDIO BASE STATION
MODEL AP-16TB-RM
Contents Description
AP-16TB-RM 8 Zone Rack Mounted Two-Way
Audio Base Station. Used for two-way communication to remote speaker/microphone units. Has Audio IN/OUT for a recorder.
Dual RCA Cable RCA cable for connection to a
DVR/VCR or other Audio devices that accept line level input (0dB @ 600W).
AD-3 +24Vdc, 1.5A power supply for powering
both the unit and the remote speaker/ microrophones
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
(818)
Ap_16tb_rm_inst_3/15
[13]
INSTALLATION AND OPERATING INSTRUCTIONS
1 2 3 5 6 7 84
MADE IN USA
ZONES
9 10 11 13 14 15 1612
[1]
[2]
[3]
[4]
[5]
PRESS
&
FILTER
[6]
TALK
VCR
OFF MAX
SIXTEEN ZONE AUDIO SURVEILLANCE w/ talkback
[7]
[8]
POWER-VOLUME
[9]
HEADPHONES
[11]
[10]
MIC
OFF MAX
AP-16TB
TALKBACK LEVEL
Fig. 1 AP-16TB
Front Panel
[12]
[1] - Zone Selector Switches Selects zone for monitoring. Press switch of desired zone to listen to live
monitored audio. Pressing any switch also provides a switch closure for activating a camera, etc. (100mA max)
[2] - Filter-OUT Indicator Lights (green) when audio filter is not in use. Indicates power is “ON”.
[3] - Filter-IN Indicator Lights (amber) when Filter Switch[6] is pressed to “ON” position.
[4] - VCR-IN Indicator Lights (yellow) when VCR Switch[7] is pressed to “ON” position.
(includes DVR’s)
[5] - Overload Indicator Current overload indicator. Lights (red) when power short circuit occurs.
[6] - Filter Switch Used only when audio playback is from a 12 or 24 hr. time lapse
recorder. Press Filter Switch[6] to illuminate red LED for 12/24 hour
(not used with DVR’s)
mode. This enhances the quality of recorded audio playback. If playback is from a DVR, filter switch is not used and should be in the “OUT” position. If no recording device is used, then filter switch must be in the “OUT” position. Otherwise live audio will be muted. The green LED illuminates when filter switch is in the “OUT” position.
[7] - VCR Switch Press switch to “ON” (or “IN”) position after connecting DVR/VCR to unit.
(When switch is “OUT”, audio bypasses the DVR/VCR and is not
(includes DVR’s)
recorded. When switch is “IN”, audio is sent in for recording and playback. Switch must always be “IN” whenever a recorder is connected.
[8] - Talkback switch Press to talk to remote speakers. Select a zone by pressing any Zone
Selector Switch[1] to talk to desired zone. A built-in Talk back Microphone[10] is located above the Headphone Jack[11].
[9] - Power-Volume Control Knob Rotating knob clockwise turns on power to the unit as indicated by the
filter-OUT indicator[2]. Green LED will illuminate. Rotating clockwise also increases loudness of monitored audio from the Monitor Speaker[13].
[10] - Talkback Microphone Built-in microphone for talkback.
[11] - Headphone Jack Used for private listening. Any 3.5mm stereo headphone with 8 to 600W
impedance may be used. Speaker is muted when headphone is used.
[12] - Talkback Control Knob Rotate knob clockwise to increase the loudness of talkback output;
counterclockwise to decrease.
[13] - Monitor Speaker Delivers audio through speaker. Muted when a headphone is plugged
into the Headphone Jack[11].
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
(818)
website: www.louroe.com e-mail: sales@louroe.com
Ap_16tb_rm_inst_3/15
INSTALLATION AND OPERATING INSTRUCTIONS
[20]
[14][19] [15]
1ZONES 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A B C
SP
G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G A B C SP G AUDIO OUT
1A
2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A
24Vdc
[18]
Fig. 2 Rear of AP-16TB
AUDIO IN
[17] [16]
[14] - Mic 5-Pin Terminal Block Connects to speaker/microphone unit at remote station.
[15] - Audio OUT Jack (RCA) Provides audio to external DVR/VCR, remote amplifiers, etc.
[16] - Aux. Microphone Accepts handheld talkback microphone (8 to 600W) with 1/4” plug.
Works the same as Talkback Microphone[10] and is used as an option.
[17] - Audio-IN Jack (RCA) Receives audio playback from external DVR/VCR, etc.
[18] - Switch Closure Terminal Block Provides a switch closure when a zone is selected by the Zone
Selector Switch[1]. Maximum current capacity of switch is 100mA. Do not connect load that will exceed this current rating.
[19] - Zone Aux. Mic Output Used for connection to a DVR with multiple audio inputs or for (each zone) connecting to another AP-16TB (paralleling two or more units).
NOTE: When paralleling to a second unit, terminal “A” is not used, as 12 Vdc is supplied to the microphone from the first base station. Also total microphone cable run must not exceed 1000 ft.
[20] - DC-IN Jack (power) Accepts 24 Vdc from external power supply (AC adapter included).
NOTE REGARDING CONNECTION TO DVR’s:
Model AP-16TB-RM is compatible with most DVR’s
If DVR has only one audio input, connect the “Audio Out” jack on back panel of AP-16TB-RM to “Audio In”[17] of DVR using an RCA cable.
If DVR has multiple audio inputs, connect the “Mic Out” jacks[19] on back panel of AP-16TB-RM to the audio inputs of DVR using RCA cables.
If DVR contains 3.5mm audio inputs instead of RCA types, a 3.5mm stereo adapter must be connected to one end of RCA cable.
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
(818)
Ap_16tb_rm_inst_3/15
INSTALLATION AND OPERATING INSTRUCTIONS
WIRING CONNECTIONS
1). Connect one end of cable to remote speaker/microphone as shown in Fig. 3. Use 4 conductor shielded audio cable such as West Penn 356. Connect wires wrapped with overall shield to terminals “A”, “B”, and “C” of microphone’s terminal block. When using West Penn 356, connect red wire to terminal “A”; black wire to terminal “B” and bare wire to terminal”C”.
2). Connect the two speaker wires (white and green) to speaker’s 70 volt transformer terminals. Connect cable’s white wire to white wire connected to the 70 volt transformer using a wire nut. Connect cable’s green wire to green wire of transformer with a wire nut.
3). Connect the other end of the cable to AP-16TB Mic 5-Pin Terminal Block[14] for the zone which the remote microphone is assigned. Make sure that wire connected to terminal “A” of remote microphone connects to terminal “A” of unit’s Mic 5-Pin Terminal Block[14]; wire connected to terminal “B’ of microphone connects to terminal “B” of unit’; “C” to “C”. If using wire from other manufacturers, color code may vary.
4). Connect white speaker wire to Mic 5-Pin Terminal Block[14] terminal “G”. Connect green wire to terminal marked “SP”.
5). Repeat steps 1 thru 3 for zones 2, 3, 4 .....16.
6). When a recorder is used (DVR, VCR etc.), connect Audio-OUT Jack[15] to recorder’s Audio-IN Jack with an RCA cable (not supplied).
7). Connect Audio-IN Jack[17] to recorder’s Audio-Out Jack.
8). Plug AC Adapter (supplied) to DC-IN Jack[20].
NOTE: If AP-16TB-RM is to be used as a one-way listen only system (no talkback), any Louroe Verifact Microphone can
®
be used. Make microphone connections as described above (see step 1). Disregard speaker connections. Use 2 conductor shielded cable, 22 gauge with a 24 gauge drain. West Penn 452 or equivalent. Same color code as in West Penn 356 (red, black and bare).
Louroe Model TLSP Speaker/Microphone
Fig. 3 Interconnection Diagram
WIRE NUT
WHITE
GREEN
GREEN WHITE
BLACK BARE
RED
A B C
REAR OF DVR/VCR
AUDIO
IN
OUT
EXAMPLE CABLE:
WEST PENN 356
2 CONDUCTOR SHIELDED #20 AWG 2 CONDUCTOR UNSHIELDED #18 AWG 1 DRAIN WIRE (BARE) #22 AWG
REAR OF AP-16TB
1ZONES 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
A B C
SP
G A B C SP G A B C SP G A B C SP G A B C SP G A B C SPG A B C SP G A B C SP G A B C SP G A B C SP G A B C SPG A B C SP G A B C SP G A B C SP G A B C SPG A B C SP G AUDIO OUT
1A
2A 3A 4A 5A 6A 7A 8A 9A 10A 11A 12A 13A 14A 15A 16A
24Vdc
AUDIO IN
AC ADAPTER
LOUROE ELECTRONICS 6 9 5 5 VALJEAN AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
(818)
Ap_16tb_rm_inst_3/15
INSTALLATION AND OPERATING INSTRUCTIONS
OPERATION AND TEST
1). To apply power, first connect small end of 24 Vdc power supply to the 24 Vdc power jack located on rear
panel [20], then plug power block into a standard 120 Vac wall outlet or power strip.
2). Turn on power to the unit by rotating the Power-Volume Control Knob[9] clockwise to “ON” position. Filter-OUT Indicator[2] should light green, indicating power is present at the unit. Rotate
Power-Volume Knob[9] further clockwise to increase the level of loudness of monitored audio.
3). Press Zone Selector Switches[1] marked zone 1. Audio from zone 1 should be present at the Monitor Speaker[13]. If there is no audio, temporarily remove wires connected to Mic 5-Pin Terminal Block[14] for zone 1 located at the rear of the unit. With a voltmeter, check that 12 Vdc is present at terminals “A” and “C”. Place positive lead of voltmeter to terminal “A” and negative to “C”. If voltage is not present, unit has defective voltage regulator. If voltage is present, check to see if the wires are connected properly to the right terminals. Otherwise microphone is defective. Call factory for assistance.
4). Press Talkback Switch[8] and speak into the Talkback Microphone[10]. Rotate Talkback Volume Control[12] clockwise to increase the level of talkback audio. Another person is needed at the remote location to listen to the volume and clarity of talkback audio.
5). Repeat steps 3 and 4 for the other zones.
6). When a 24 hour VCR is connected to the unit, press VCR Switch[7]. VCR-IN Indicator[4] will light yellow. Start recording live audio. It is not necessary to use VCR switch if recording into a DVR. The VCR Switch[7] must be in the “OUT” position when a recorder is not connected to the unit. Otherwise live audio will be muted.
7). Recorded audio can be played back through the AP-16TB-RM’s built-in amplifier and speaker. If audio playback is from a 24 hour time lapse recorder, press Filter Switch[6] to 12/24 hour mode. Filter In indicator[3] will illuminate red. If playback is from a DVR, filter switch is not used and should be in the “OUT” position. If no recording device is used, then filter switch must be in the “OUT” position. Otherwise live audio will be muted. The green LED will illuminate when filter switch is in the “OUT” position.
SPECIFICATIONS
Monitor power output
Talkback power output
Input sensitivity
(Talkback microphone)
Audio line output impedance
Audio input impedance 10kW Audio frequency response 100 Hz to 10kHz Audio frequency
response (enhanced)
Headphone impedance 8 to 600W Switch Closure Rating 100mA Power input 24 Vdc, 1.5A Dimensions 19”L x 7”W x 12 1/2”D Weight
Shipping Weight
1W @ 8W
1.5W into 70V line
-45 dB
600W
-20 dB @ 200 Hz to +5dB @ 3kHz
10 lbs 14 oz
15 lbs
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
(818)
Ap_16tb_rm_inst_3/15
INSTALLATION AND OPERATING INSTRUCTIONS
NOTES
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
(818)
Ap_16tb_rm_inst_3/15
INSTALLATION AND OPERATING INSTRUCTIONS
IMPORTANT NOTICE
When this equipment is used as part of an audio monitoring system, the law requires that the public be given notice of AUDIO MONITORING ON THE PREMISES. A deca l noti ce is in clud ed wit h each microphone shipped.
Federal Law References: Federal Regulations, US Code, Title 18. Crime and Criminal Procedure, Sec 2510.
LOUROE ELECTRONICS warrants that at the time of shipment products manufactured by LOUROE ELECTRONICS to be free of defects in material and workmanship. Should a defect appear within one year (12 months) from date of shipment, LOUROE ELECTRONICS will, at its sole discretion, repair or replace the defective equipment. This equipment shall not be accepted for repair or return without prior notification by LOUROE ELECTRONICS .
This warranty does not extend to any Louroe product that has been subjected to improper or incorrect installation, misuse, accident, or in violation of installation instructions provided by LOUROE ELECTRONICS.
Returned shipments to LOUROE ELECTRONICS shall be at customer’s expense. LOUROE ELECTRONICS will return the equipment prepaid via best way.
®
®
®
WARRANTY
AUDIO
MONITORING
On
These Premises
®
®
®
®
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
(818)
Ap_16tb_rm_inst_3/15
INSTALLATION AND OPERATING INSTRUCTIONS
MANUFACTURED
IN THE
LOUROE ELECTRONICS 6 9 5 5 VA L J E A N AVENUE, VAN NUYS, CA 91406 TEL (818) 994-6498 FAX 994-6458
®
website: www.louroe.com e-mail: sales@louroe.com
(818)
Ap_16tb_rm_inst_3/15