Lotus Press LTS 500, LTS 510 Operating Instructions Manual

Operating Instructions for semi-automatic
Heat Transfer Press LTS 500 / LTS 510
LOTUS TRANSFER PRESS SOLUTIONS GmbH & Co. KG
Via Giambellino 14a
Anklamer Straße 38
20146 Milan ITALY
10115 Berlin GERMANY
Tel. +39. 02. 48 95 03 86 Fax +39. 02. 48 95 23 55
Tel. +49. 30. 40 50 45 8 45 Fax +49. 30. 40 50 45 888
info@lotuspress.it / www.lotuspress.it
info@lotustransfers.de / www.lotustransfers.de
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 2 / 12
Thank you very much for buying one of our Lotus heat transfer presses. We are sure you will capitalize on this excellent unit for years if you take the time to read these instructions carefully.
Introduction
Please study these instructions carefully before transporting, mounting, using or maintaining the transfer press, as they will give you important directions for a safe handling. Moreover you will find information about how to order spare parts in this manual.
Please retain these instructions for later reference in a safe, easily accessible place. Please make sure that all operators of the transfer press have understood all instructions
and graphic symbols labelled on the press. Accidents can also be avoided by strictly following the safety regulations according to
the machine directive 89/37/CEE replaced by 2006/42/CEE - 73/23/CEE replaced by LVD 2006/95/CEE – 89/336/CEE replaced by EMC 2004/108/CEE – EN 292/1 – EN 292 replaced by UNI EN ISO 12100 and UNI ENI ISO 12100-2 – EN 60204.
It is specifically prohibited to remove or manipulate shrouds or legally compulsory labels or plates.
Contents
1. Warranty
2. Technical Data
3. Operating the Transfer Press
4. Safety Regulations
5. Mounting, Transport and Mounting Location
6. Electrical Connection
7. Directions for Use
8. Maintenance
9. Dismantling and Disposal of Transfer Press
10. Spare Parts in exploded view with order numbers
11. Electronic Diagram p.1
12. Electronic Diagram p.2
13. Construction of heating plate
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 3 / 12
1. Warranty
Lotus Transfer Press Solutions GmbH & Co. KG provide you with a 12 months warranty on all their transfer presses (from date of purchase).
To submit a warranty claim is only possible if the transfer press has been mounted and used according to the instructions in this manual and all necessary maintenance has been regularly performed.
During the warranty period defective or broken parts will be repaired free of charge by Lotus Transfer Press Solutions GmbH & Co. KG Milan/Italy.
Transport and shipping expenses are on buyer's account.
The reclaim of defective parts after their replacement is at the discretion of Lotus Transfer Press Solutions GmbH & Co. KG.
Parts needing to be replaced because of maintenance, wear or carelessness are not included in this warranty.
Any claims of consequential costs of a loss or damage, e.g. loss of production, are explicitly excluded from this warranty. No distributor, representative or agent is authorized to assume for Lotus Transfer Press Solutions GmbH & Co. KG any other obligation or liability or to submit a statement different from the one mentioned above.
By accepting this warranty the customer waives every compensation for losses or damages arising from a production stop.
2. Technical Data
Model
LTS 500
LTS 510
Transfer area
100 x 70 cm
100 x 80 cm
Heating energy
5400 W
5400 W
Temperature
0 - 250 °C
0 - 250 °C
Timer
0 - 99 sec
0 - 99 sec
Weight
180 kg
185 kg
Voltage
380 V
380 V
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 4 / 12
3. Operating the Heat Transfer Press
This heat press can be used for transferring thermically weldable materials onto any kind of textiles.
Not more than one person may operate the press at a time. Avoid exceeding the specified maximum temperature when operating the press.
Lotus Transfer Press Solutions GmbH & Co. KG is not liable for faults, accidents, damages, losses etc. resulting from not following the instructions in this manual.
Note: It is strictly forbidden to operate or mount this transfer press contrary to the directions made in this manual.
4. Safety Regulations
Before operating the transfer press, the operator must have fully understood the handling and function of the electric components of this transfer press and must have read and grasped all information provided in this manual.
NOTE: There is the risk of getting burned if you touch the heating plates during operation. We strongly advise the operator to wear protective gloves providing protection up to a temperature of 299 ° C.
Avoid to touch the heating plates of the transfer press during operation and for a period of 15 minutes after the press has been switched off, as the operating temperature of the press is very high. Please also avoid to touch the lower supporting plate when closing the press or printing the textile, as these operations involve a risk of getting squashed and burned.
It is strongly recommended that only one person operates the transfer press.
Any kind of maintenance and / or repair work on the transfer press must only be performed after the heating plate has been switchedoff and has cooled down to ambient temperature.
Do not use the transfer press in a humid or wet environment. Before swapping the heating plates, switch off the unit and allow it to cool down to ambient temperature.
Do not perform any transfers to textiles containing solvents, flammable liquids, gaseous or liquid fuels.
Unauthorized changes of the unit or the replacement of parts without consent of Lotus Transfer Press Solutions GmbH & Co. KG are prohibited.
Lotus Transfer Press Solutions GmbH & Co. KG is not liable for damages, losses,
injuries or consequential damages resulting from acts, changes or other use of the
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 5 / 12
transfer press not authorized by a prior written consent from Lotus Transfer Press Solutions GmbH & Co. KG
All mounting, maintenance and repair work must be performed only by skilled and specially trained electricians.
It is strictly prohibited to remove or manipulate any kind of safety appliances.
The working area must be clean, tidy and free of any obstacles for maneuvering the heat transfer press.
All general instructions for operation and all safety instructions must be strictly followed to avoid any injuries that might result from the use of this transfer press and to ensure a successful utilization of the press.
5. Mounting, Transport and Mounting Location
Only suitably qualified staff may perform the mounting of the transfer press as the electrical connections must comply with local regulations.
Before mounting the heat transfer press prepare a suitable mounting location. Handle the package containing the transfer press with care and with the aid of suitable tools.
For the mounting location you need a stable table with a height of approximately 70 cm.
6. Electrical Connection
The heat transfer press must be mounted in a room featuring a power supply system approved by local authorities and complying with effective safety regulations for electric devices.
The available power supply lines must have a cross section sufficient for the transfer press's energy demand, preferably in its own power circuit. The characteristic values of the power supply system must comply with the characteristics of the heat transfer press. Please check the values stated on the manufacturer's label.
The colored conductor markings must be carefully complied with and the transfer press must be earthed. Please refer to EN 60439 – 1 (CEI 17-13/1).
The power socket must have an electric protective earthing and a residual-current operated protective device (RCD) disconnecting the circuit if the residual current exceeds 30 mA.
Do not use cables with damaged insulation. It is inadvisable to use extension cords.
Remove the plug from the power socket before starting any maintenance or repair work, in particular if it is necessary to open the box of the control panel or to perform work on the heating elements.
The graphic symbol „High-Tension“ signalizes a serious danger and is attached on the box of the control panel and on top of the heating elements. Switch off the master switch before exchanging or removing heating elements.
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 6 / 12
7. Directions for Use
Please note the risks involved in using a transfer press mentioned in paragraph 4 of this manual, in particular x the risk of squashing your hands in between the plates
x the risk of an electric shock x the risk of burning your hands and arms on the heating plates
Wear protective gloves to avoid the risk of getting burned.
1) Plug the connector cable into a power socket of 380 V.
2) Set the main switch from 0 to 1. In ON position a pilot lamp will glow. Now the desired operation parameters can be set.
3) The temperature unit is on the right side of the press. The temperature is being set
by pressing the button ^ at the temperature unit until the desired temperature is
shown on the display. The temperature lamp will switch off, showing that the heating plate has reached the desired temperature. Also a light on the right side will switch on until the desired temperature is reached.
4) Now set the desired pressing time at the timing unit also on the left side. Turn the number-wheels until the requested transfer time is shown on the display. You will see the count-down of the set numbers on the electronical timing display in the timing unit. After the set time has reached zero an acoustic signal will be heared as well as a signal lamp will be shown. Now the heating plate will release automatically!
5) Find out the necessary printing pressure by trial printing.
6) To adjust the pressure, turn the pressure controller
- clockwise to increase the pressure
- anti-clockwise to reduce the pressure
The press needs to be open, when adjusting the pressure! A pressure adjusting with a closed press can cause serious damages at the press!
7) Put the textile to be printed on the supporting plate and place the desired transfer onto it.
8) To start the transfer process, pull down the lever. This will cause the press to close and the heating plate will be pressed onto the supporting plate. The transfer process is running now. As stated before, after the set time has elapsed, an acoustic signal and a signal lamp announce the release of the press. Now the heating plate will release automatically.
9) Switch off the transfer press when you do not use it.
8. Maintenance
Following the safety directions mentioned below is essential to avoid severe injuries to the operator and/or damage to the transfer press.
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 7 / 12
Before performing any maintenance work, the transfer press must have been switched off and the plug must have been removed from the power socket.
Note the high temperatures of the top heating plate. It can take up to 15 minutes until the plate has cooled down to a temperature below 50° C.
Carefully follow the instructions mentioned in this manual before performing any maintenance or cleaning work on the transfer press.
Maintenance work must only be performed by skilled and specially trained staff. Before switching on the unit again after maintenance or cleaning work, ensure that no
tools or spare parts have been left in or on the unit and that shrouds, safety appliances, graphic symbols and instructions attached to the press are in good condition and easy to read.
9. Dismantling and Disposal of the Heat Transfer Press
All work for dismantling or disposal must be performed by sufficiently qualified staff.
A transfer press is an industrial unit. All applicable laws must be followed concerning the disposal of industrial machinery in the country of the user.
Disconnect the unit from the power supply and dismantle it. Sort the parts according to their composition, e.g. aluminum, plastic, steel, mineral wool etc. The disposal of these material groups must be performed in accordance to the applicable laws in the country of the user.
Strictly follow the safety instructions mentioned in this manual when dismantling the press.
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 8 / 12
10. Spare Parts LTS 500
01 BRACKET RIGHT - BRACKET LEFT 02 METALL COVER 03 HEAT PLATE 04 CABLE FIXING HEATING PLATE 05 FIXING HEATING RODS 06 HEATING RODS 07 SPRINGS IDLERS TEFLON 08 TEFLON 09 FELT 10 TABLE SPRING LOADED 11 THREADED 12 ARM COVER 13 MAGNET 14 MICROSWITCH 15 ARM 16 RED LIGHT BULB 17 GREEN LIGHT BULB 18 PIVOT ARM 19 BRACKETS FOR KNOB 20 PIN FOR KNOB 21 KNOB 22 CARTER UPPER BASE 23 SPRING BALANCE TRACTION 24 CARTER BACK 25 SHOCK 26 BASE 27 PIN UNION 28 PROTECTION SPRING 29 RELAY 30 ELECTRONIC BOARD PRESSURE REGULATION 31 MAINSWITCH 32 POTETIOMETER 33 EMERGENCY STOP 34 ELECTRONIC TIMER 35 ELECTRONIC TEMPERATURE REGULATOR 36 FEET 37 TEMPERATURE SENSOR
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 9 / 12
10. Spare Parts in exploded view with order numbers
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 10 / 12
11. Electronic Diagram
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 11 / 12
12. Electronic Diagram
Operating Instructions
Heat Press
LTS 500 / LTS 510
page 12 / 12
13. Construction of heating and pressure plate
Loading...