LOREX Technology SG7965 User Manual

1280 Hr Time Lapse VCR
40 Hr Real-Time with Jog Shuttle
INSTRUCTION MANUAL
English Version 1.0
Real Time & High Density
CLOCK COUNT
ALARM
KEY LOCK
BUZZER OFF
LOCK OFF
REMAIN
CLEAR
Model: SG7965
www.lorexcctv.com
2
INTRODUCTION
WARNING : TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,
DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.
If you pour a cold liquid into a glass, water vapor in the air will condense on the surface of the glass. This is moisture condensation. Moisture condensation on the head drum, one of the most crucial parts of the unit, will cause damage to the tape. When the VCR is exposed to a rapid temperature change from cold to warm, some condensation will occur. Under this condition, connect the power cord to the AC line, press POWER/TIMER button on and allow at least two hours for the VCR to dry out.
MOISTURE CONDENSATION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
CAUTION : TO REDUCE THE RISK
OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK);
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
The serial number is found on the back of this unit. This number is unique to this unit and not available to others. You should record requested information here and retain this guide as a per­manent record of your purchase.
Model No.
Serial No.
CAUTION : TO PREVENT ELECTRIC SHOCK, DO NOT USE THIS PLUG WITH AN EXTEN­SION CORD, RECEPTACLE OR OTHER OUT­LET UNLESS THE PLUG CAN BE FULLY INSERTED WITHOUT EXPOSING ANY PARTS OF THE BLADES.
This lightning flash with arrowhead sym­bol within an equilateral triangle is intend­ed to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of suffi­cient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilater­al triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
WARNING: Do not install this equipment in a con­fined space such as a bookcase or similar unit.
CAUTION: The apparatus should not be exposed to water (dripping or splashing) and no objects filled with liquids, such as vases, should be placed on the apparatus.
IMPORTANT COPYRIGHT INFORMATION: Many television programs and films are copyrighted. In certain circumstances, copyright law may apply to private in-home video taping of copyrighted materi­als.
Warning : This is a class A product . In a domestic environment this product
may cause radio interference in which case the user may be required to take adequate measures.
3
CONTENTSFEATURES
INTRODUCTION
Features/Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
PREPARATION
Control Names and Locations . . . . . . . . . . . . . . . . .4-8
Installation & VCR to Monitor and CCD
Camera Connection . . . . . . . . . . . . . . . . . . . . . . . . . .9
Multiplexer/Matrix Switcher Connections . . . . . . . .10-11
Alarm Record Connection . . . . . . . . . . . . . . . . . . . . .12
Series Record Connection . . . . . . . . . . . . . . . . . . . . .12
Setting the On Screen Display . . . . . . . . . . . . . . . . . .13
Setting the VCR SET UP Menu . . . . . . . . . . . . . . . . .14
Setting the Set Time . . . . . . . . . . . . . . . . . . . . . . . . .15
Video Cassette Tapes . . . . . . . . . . . . . . . . . . . . . . . .16
PLAYBACK
Normal Playback . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Special Effects Playback . . . . . . . . . . . . . . . . . . .18-19
Tape Counter Memory Feature . . . . . . . . . . . . . . . . .20
RECORDING
Normal Recording . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Repeat Recording . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Timer Recording . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Series Recording . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Alarm Recording . . . . . . . . . . . . . . . . . . . . . . . . .25-26
ADDITIONAL INFORMATION
Check the Alarm Record Information . . . . . . . . . . . . .27
Recording Time Table Information . . . . . . . . . . . . . . .27
Check the Power Fail Recall . . . . . . . . . . . . . . . . . . .28
Key Lock Function . . . . . . . . . . . . . . . . . . . . . . . . . .28
Self-Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Service Guide Table . . . . . . . . . . . . . . . . . . . . . . . . .30
VIDEO Head Cleaning . . . . . . . . . . . . . . . . . . . . . . .30
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
• Time Lapse VCR Function
• Trigger Function
• Buzzer Function
• Auto Switcher Functionality
• Tape Compatibility
• Elapsed Time Display
• Series Recording Function
• Alarm Recording Function
Warning : The battery used in this device may present a fire or chemical burn hazard if mis-
treated. Do not recharge, disassemble, incinerate, or heat above 212°F (100°C). Replace the battery with Matsushita Elec. Ind., Co., Ltd. (Panasonic) part no. VL2330 only. Use of another battery may present a risk of fire or explosion. Dispose of used batteries. Keep away from children. Do not disassemble or dispose of in fire.
INTRODUCTION
CONTROL NAMES AND LOCATIONS
FRONT
PREPARATION
CLOCK COUNT
BUZZER OFF
LOCK OFF
REMAIN
CLEAR
ALARM
KEY LOCK
REMOTE CONT R OL
4
1 2
3
7
8 9 10
4
11 12
5 6
13 14
15
V
V
vv
v
FRONT
CONTROL NAMES AND LOCATIONS
1. POWER/TIMER button
(Press for on; press again for off) The display window becomes brighter when the VCR is switched on.
Timer function is activated when power switch is in the Off position.
2. MENU button
Press to activate the Menu selection.
3. REC (RECORD) button
Press to begin recording.
4. MOVE button
Press to change a value in Menu mode
or to operate tracking during playback
or slow. Press repeatedly to move the Time and Date display’s position. If a still picture vibrates vertically, stabi­lize it by pressing the MOVE button.
5. SEL (SELECT) button
Press to change the value or to operate tracking during playback or slow. If a still picture vibrates vertically, stabi­lize it by pressing the SEL button.
6. DOWN button
Press to set speed in descending order 30H,
18H, 6H.... during recording or playback.
7. UP button
Press to set speed in ascending order
6H, 18H, 30H.... during recording or play-
back.
8. ALARM Indicator
Illuminates when alarm record is set on and blinks during alarm record. It can be turned off by setting REC MODE to OFF under ALARM SET UP menu (only when there is no alarm record informa­tion on the ALARM RECALL menu. To erase the alarm record information, refer to “To erase the alarm record informa­tion” on page 27).
9. KEY LOCK Indicator
Illuminates during key lock mode is activated.
10. Cassette loading slot
Cassette tape is inserted in this slot.
11.CLEAR, KEY LOCK OFF, BUZZER OFF
Press to delete the information stored on screen display, such as Alarm recall, Power fail and Timer program. It can also be used to stop the buzzer sound and to release key lock mode if it is held for at least 3 seconds.
12. CLOCK, COUNT, REMAIN
Pressing this button toggles between the CLOCK, COUNT, and REMAIN displays. CLOCK shows the current time. COUNT shows the incremental counter for recording or playing, and REMAIN indi­cates the remaining time on the tape.
13. Shuttle Ring
Refer to page 19.
14. Jog Ring
Refer to page 19.
15. PAUSE/STILL button
When pressed during recording, tape movement stops temporarily. Press again to continue the recording. When pressed during playback, tape movement stops. Press again to advance by still frame. It can also be used to search alarm recording by pressing this button in stop mode.
16. PLAY/REC CHECK button
Press to play back a previously recorded tape. Press this button during recording to confirm the recording operation. It plays back the recording on screen for 4 seconds and returns to recording mode.
17. STOP/EJECT button
Press once to discontinue all tape related
functions. Press again to eject the cas­sette.
PREPARATION
5
6
PREPARATION
CONTROL NAMES AND LOCATIONS (cont’d)
1. POWER CORD
Connect only to an AC 100-240V, 50/60Hz outlet.
2. AUDIO IN/OUT JACK
Connect the audio input and output terminal.
3. VIDEO IN/OUT JACK
Connect the video input and output terminal.
4. RESET BUTTON
Use this button to reset the VCR.
5. 12-PIN TERMINAL BLOCK
Connect external signals.
VIDEO IN
AUDIO IN
AUDIO OUT
VIDEO OUT
1 2 3 456 7 8 9 10 11 12
RESET
1
ALARM IN
2
ALARM OUT
3
ALARM RESET
4
GND
5
SERIES IN
6
SERIES OUT
7
WARNING OUT
8
TRIGGER OUT
9
GND
10
LOW TAPE OUT
11
1 SHOT REC IN
12
GND
REAR
1
2
3
4
5
TERMINAL SIGNAL LEVEL IN/OUT
1. ALARM IN INPUT
2. ALARM OUT OUTPUT
3. ALARM RESET INPUT
5. SERIES IN INPUT
6. SERIES OUT OUTPUT
7. WARNING OUT OUTPUT
8. TRIGGER OUT OUTPUT
10. LOW TAPE OUT OUTPUT
11. 1-SHOT REC IN INPUT
4, 9, 12. GND COMMON
VIH
VIL
T
VOH
VOL
T
VIH
VIL
T
VIH
VIL
T
VOH
VOL
T
VOH
VOL
T
VOH
VOL
T
VOH
VOL
T
VIH
VIL
T
Terminal Signal Levels
VIH: 4~5V, VIL: 0~0.6V T: above 250msec
VOH: 4~5V, VOL: 0~0.6V T: ALARM REC STATE VIH: 4~5V, VIL: 0~0.6V T: above 250msec
VIH: 4~5V, VIL: 0~0.6V T: above 250msec
VOH: 4~5V, VOL: 0~0.6V T: above 250msec
VOH: 4~5V, VOL: 0~0.6V T: until any key is pressed VOH: 4~5V, VOL: 0~0.6V T: above 8~10msec
VOH: 4~5V, VOL: 0~0.6V T: below 5 min, end of tape
VIH: 4~5V, VIL: 0~0.6V T: above 250msec
0V
7
PREPARATION
REMOTE CONTROL
1. POWER button
1 2
3
4
5 6
7
2. UP button
8 9
3. TR V button
10 11
12
4. MENU button
13 14
5. P/STILL button
15
6. REW (Rewind)
7. EJECT
8. ENTER (SELECT) button
9. TR vv(MOVE) button
10. DOWN button
11. REC/PLAY HOURS button
12. STOP
13. REC (RECORD) button
14. FF (Fast Forward)
15. PLAY (PLAY/REC CHECK) button
(Press for on; press again for off) The display window becomes brighter when the VCR is switched on.
Timer function is activated when power switch is in the Off position.
Press to set speed in ascending order 6H, 18H, 30H.... during
recording or playback.
To operate tracking during playback or slow. If a still picture vibrates vertically, stabilize it by pressing the TR V button.
Press to display current status on TV screen. You can change its contents.
When pressed during recording, tape movement stops temporari­ly. Press again to continue the recording. When pressed during playback, tape movement stops. Press again to advance by still frame. It can also be used to search alarm recording by pressing this button in stop mode.
To rewind the tape during the STOP mode or for fast reverse pic­ture search during playback.
Press to eject the cassette in the VCR.
Press to change the value or to operate tracking during playback or slow.
Press to change the value or to operate tracking during playback or slow. If a still picture vibrates vertically, stabilize it by pressing the TR v button.
Press to set speed in descending order 30H, 18H, 6H.... during
recording or playback.
Press to set speed in ascending order 6H, 18H, 30H.... during
recording or playback.
Press to discontinue all tape related functions.
Press to begin recording.
To advance the tape during the STOP mode or for fast forward picture search.
Press to play back a previously recorded tape. Press this button during recording to confirm the recording operation. It plays back the
recording on screen 4 seconds and returns to recording mode.
8
PREPARATION
ALARMHSERIES TIMER
INDEX P.FAIL
K.LOCK
REPEAT
REC
INDICATOR PANEL
1. TIME LAPSE VCR TIME Indication
2. ALARM Indication (ALARM REC ON indication)
3. SERIES Indication
4. RECORD Indication
5. TIMER Indication
6. CASSETTE Indication
7. INDEX Indication
8. POWER FAILURE Indication
9. KEY LOCK indication
10. REPEAT Indication
11. FUNCTION Indication (CLOCK, TAPE COUNTER, ERROR)
12. VCR FUNCTION Indication
VCR FUNCTION Indication
PLAYBACK INDICATION RECORDING INDICATION
PLAYBACK
PAUSE STILL
FAST FORWARD
REWIND
CUE
REVIEW
RECORDING
TIMER RECORDING
ALARM INDEX
ALARM RECORDING
SERIES RECORDING
FORWARD SLOW PICTURE/ FORWARD FIELD ADVANCE
REVERSE SLOW PICTURE/ REVERSE FIELD ADVANCE
CONTROL NAMES AND LOCATIONS (cont’d)
1234567
12 11 10 9 8
9
PREPARATION
INSTALLATION
VCR TO MONITOR AND CCD CAMERA CONNECTION
The cables for audio and video connection are not provided with your VCR.
Connect your VCRs AUDIO/VIDEO output jacks to the A/V input jacks on back of your monitor.
Connect the CCD camera to VCRs VIDEO input jack.
10
PREPARATION
MULTIPLEXER CONNECTIONS
HOW TO CONNECT MULTIPLEXER WITH TRIGGER INPUT TERMINAL
If the multiplexer has two output terminals (MONITOR OUT, PB OUT), connect monitor to the PB OUT terminal if you want to see the playback picture. To use the multiplexer and trigger function properly, refer to the multiplexer instruction manual.
Loading...