Logilink ITP7A-0100S-VL, ITP7A-0200S-VL Datasheet

Installation Cable S/FTP Cat.7A, 1200MHz, PrimeLine
LogiLink’s Category 7A high end cables are manufactured in Europe in accord­ance with ISO IEC 61156 requirements. It is the best choice for future proof structered horizontal cabling. These cables are ideal for LAN data transmission in all Ethernet (IEEE 802.3) applications up to 10 GBase-T and higher. The copper braid overall screen offers protection against electromagnetic interference as well as mechanical reinforcement.
Technical Specifications
- Solid Installation Cable Cat.7A 1200 MHz
- 4x2x23AWG bare copper conductor
- 4 individually screened pairs (PIMF)
- Tin plated copper braiding overall screen
- Fire safety class FRNC-C according to IEC 60332-3
- Fast-, Gigabit- & 10 Gigabit Ethernet
- ISO/IEC 11801, EN 50173-1, IEC 61156-5
1. Conductor: 100% copper solid wire
1
2
3
4
5
6
2. Insulation: PE compound
3. Twisting: 2 cores twisted in a pair
4. Individual Screen:
Overlapped laminated aluminium foil
5. Overall Screen: Braiding of tinned copper wires
6. Outer jacket: LSOH compound
Cable type Dimension Sheath Sheath
Simplex 4x2x23 AWG LSOH Violet 7.6 59.0
Duplex 2x (4x2x23 AWG) LSOH Violet 7.6x15.5 121.0
Part no. Length
CQ6100S 100 Reel
CQ6200S 200 Reel
CQ6500S 500 Bobbin
CQ6000S 1000 Bobbin
CQ6100D 100 (Duplex) Reel
CQ6500D 500 (Duplex) Bobbin
Color
(m)
Outer diameter (mm)
Packaging
Cable weight (kg/km)
Operation Conditions
Static Dynamic
Temperature range
(Indoor)
Bending radius Static 4 x D Dynamic 8 x D
Fire behaviour
Pro LSOH cable
-20°C to +60°C 0°C to +50°C
IEC 60332-3-24, IEC 60754-2, IEC 61034
*All trade names referenced are the registered namework of their respective owners.
* The specifications and pictures are subject to change without notice.
Basic Transmission Characteristics (20°C)
Frequency
MHz
4 3.5 3.4 75 110 78.0 105 23.0 28
10 5.4 5.0 75 110 74.0 105 25.0 33
16 6.8 6.6 75 110 70.0 102 20.0 33
31.25 9.6 9.4 75 110 64.0 96 23.6 32
62.5 13.7 13.4 75 110 58.0 96 21.5 31
100 17.5 17.2 73 110 54.0 96 20.0 33
200 25.3 24.2 68 110 48.0 91 18.0 32
300 31.5 30.4 66 110 44.0 86 17.3 29
600 46.3 44.0 61 106 38.0 76 17.3 26
900 58.3 53.6 59 105 35.0 55 15.5 24
1000 62.0 56.1 58 91 34.0 52 15.5 23
1200 - 61.4 - 90 - 49 - 23
Attenuation dB/100m
Cat 7E max. Typical value
NEXT dB
Cat 7E max. Typical value
Basic Electrical Characteristics (20°C)
ELFEXT dB
Cat 7E max. Typical value
Cat 7E max. Typical value
Return loss dB
- DC Conductor Resistance: ≤65 Ohm/km
- Insulation Resistance: ≥5000 MΩkm / 500 VDC
- Mutual Capacitance: ≤43 nF/km / 1.0 KHz
- Capacitance pair to ground: ≤1500 pF/km / 1.0 KHz
- Characteristic Impedance: 100 ± 7% Ω / 1-100 MHz;
100 ± 10% Ω / 100-250 MHz
100 ± 15% Ω / 250-600 MHz
- Fitted Impedance: 100 ± 5 Ω at 100 MHz
- Velocity of Propagation: 79 % nom.
- TCL: min 50-10xlog(f) at 1 to 250 MHz
- Dielectric Strength: 1000 Volts / 1 minute DC
- Transfer Impedance: <7 mOhm/m at 10 MHz
Identification Color Coding
- Pair 1: White / Blue
- Pair 2: White / Orange
- Pair 3: White / Green
- Pair 4: White / Brown
Sheath Marking
“LOGILINK S/FTP 4x2x23 AWG Cat7E 1200 MHz LSOH in accordance
with ISO/IEC 11801/ EN 50173 + IEC61156-5 – Length m”.
*All trade names referenced are the registered namework of their respective owners.
* The specifications and pictures are subject to change without notice.
Loading...