Logik LUF55B13, LUL55B13 Service Manual

Refrigerator
Service Manual
Models: LUF55B13
Energy efficiency
Micro foam technology
Low noise operation
Thick insulation for energy efficiency
Latest No. 2 micro-biological technology
0
CONTENT
CONTENT
1. Content.
1
2. Product code illumination and Series Introduction 2
3. Specifications.... 3
4. Safety precautions.... 4
5. Function Schedule........ 7
6. System Flow Chart..... 8
7. Circuit Diagram..... 9
8. Maintenance Service and Trouble Shooting.... 10
9. Exploded View... 30
10. List of Parts... 31
1
Specifications
Specifications
Models
capacity
(L)
LUF55B13
86
Color
Black
Power Supply
(V/Hz)
220V/50HZ
Rated Input Power
(W)
70
Power Consumption (kW·h/Y)
183
Net Weight
(kg)
32.1
Gross Weight
(kg)
Unit Dimension
(D*W*H)
(mm)
Packing Dimension
(D*W*H)
(mm) Container Quantity
40'HQ (PCS)
34.5
574x553x845
600x580x880
236
3
Safety precautions
Safety precautions
4
Safety precautions
5
Safety precautions
6
Function Schedule
Function Schedule
Energy efficiency
Micro foam technology
Low noise operation
Thick insulation for energy efficiency
7
System Flow Chart
System Flow Chart
1 Schematic diagram of System Flow Chart
Flows in the
sequence: 1->2->3->4->5>1
8
Circuit Diagram
Circuit Diagram
1 Schematic Circuit Diagram
9
Maintenance Service and Trouble Shooting
Maintenance Service and Trouble Shooting
1. No cooling
No cooling
If compressor
can run after it stop to
run five minutes and
give power.
NO
Check and repair according to the section of "the compessor doesn't work".
YES
If compressor can run naturally and temperature raising
of condenser is
very low
YES
NO
Refrigerant leak,check and repair charge refrigerant again.
Block by ice or dirty things,change filter and change refrigerant again.
!
When charging refrigerant,we must notice to make refrigerant true.
10
Loading...