Logic Six LGSIX/01 Engineering Information

Intruder alarm system
Engineering Information
LGSIX/01 Logic Six panel with two pre learnt Keyfobs
The above intruder system is designed to comply with the installation requirements of BS 4737 1986/87.
Accenta
/!
mini
Learn
Error
Day
1 2 3 4 5 6
TA
PA
Power
ZONE
Features
ÿ
6 Security zones
ÿ
PA input
ÿ
Tamper input
ÿ
Outputs for External siren (Bell) and Strobe
ÿ
Pre-configured Part set program selectable by DIP switch.
ÿ
Entry Time duration selectable by DIP switch
ÿ
Entry Deviate
ÿ
Alarm Cycle Counter
ÿ
Strobe confirmation on Set
ÿ
Memorises first and subsequent zone intrusions in one alarm period
ÿ
Walk Test facilities by push button control
ÿ
Alarm Test facilities by push button control
ÿ
Battery capacity of up to 2.1Ah
ÿ
Up to 8 keyfobs can be used with the panel (2 Keyfobs supplied pre learnt)
ÿ
Learn mode to learn new keyfobs
ÿ
Erase mode to disable lost or stolen keyfobs
2 4188-753 issue 1_1/03
Engineering information
Contents
Features -------------------2 Installation Design --------------3 Fixing the control panel -----------3 Wiring the system --------------4 Tamper network ---------------4 Security zones ----------------5 PA circuit ------------------6 Extension speaker --------------7 External siren Output (Bell box) -------8 13V Supply output --------------9 Set ---------------------9 Factory set condition -------------10 Zone Function ----------------10 First Power up ----------------11 Mains Connection --------------11 Testing the system --------------12 System indications --------------12 Programs ------------------12 Walk tests ------------------13 Alarm tests -----------------13 How to learn new keyfobs ----------14 How to re-learn all keyfobs ----------15 How to learn keyfobs if non are recognised - - 16 Re-arm -------------------17 Alarm Cycle Counter-------------17 Faults --------------------18 Specification-----------------19 Servicing organisation Details --------20 Parts --------------------20
Installation Design
The purchase of this alarm system represents a major step forward in the protection of the property and its occupants. It is important to plan the installation before proceeding following the procedures and advice contained in this manual.
Plan the position of each part of the alarm system and the cable runs. Detectors should be sited with particular regard to the degree of coverage required
and the function of each of the zones.
All of the system wiring is connected directly to the panel. The intruder panel must be installed near an entry/exit point.
One additional internal sound speaker is recommended, it will provide high volume alarm tones and low volume
entry/exit tones. Speakers should be positioned to provide good sound distribution throughout the building and so that the exit tone is audible outside the main entry / exit door. This will enable the system operator to check that the system is setting correctly.
Finally note that the total current output of this control system (in alarm condition) is 1A when supported by a fully
charged battery. Calculate the total current consumption of every part of the system including the panel, external siren with strobe light (bell box) and detectors to ensure that this rating is not exceeded.
Depending on which area you
live, you may be required, by
law to notify the Local
Authority and Police of the
new security alarm installation. The local authority requirements may differ from area to area, therefore it is advisable to contact local environmental officer to obtain full details of your area requirements.
Fixing the control panel
Caution: When positioning the control panel ensure that it is located in a dry place away from damp areas.
a. Remove the front cover(s) from the
base assembly.
Disconnect the transformer wires from the board, these are marked AC. Carefully remove the board by gently pushing down the holding clips on the bottom edge of the board and withdraw it from the base.
Note: When replacing the board align it on the round support pillars to the bottom and allow it to click down past the clips at the top of the case. Refit the transformer wires into the terminal.
Logic Six intruder system
ZONES
P
ow
er
Error
D
ay
1
2
3
4
5
6
TA
PA
Learn
LA
I
TOTAL
Power
b. Fit the panel to the wall with suitable
fixings. Ensure the wall surface is flat to prevent base distortion. There are cable entry holes provided in the rear of the base and around the outside edges through the thinned out plastic sections which may be cut away as required.
c. The hole provided adjacent to the
mains transformer is a dedicated mains cable entry point.
Board
There are three fuses mounted on the circuit board, all are 20mm quick blow.
F1 1.6A - to protect the +ve line of 12V battery F3 1A - to protect the Speaker 13V supply F5 1A - to protect the Siren & Strobe
supply As supplied, there are wire links are fitted across
the PA and Tamper terminals to represent a closed circuit.
Wiring the system
Caution: Always power-down the panel when wiring external circuits, to prevent damage to the panel electronics.
Systematically wire and test each circuit:
ÿ
Zones, Tamper and PA circuits
ÿ
Finish by wiring any additional extension speaker sounders, external siren (bell) / strobe and the 13V supply.
Tamper network
The Tamper circuit is used to protect all cables and detectors in the system from unauthorised access including the panel cover.
The zone and PA tampers should be series wired and connected to the TAMP terminals. The terminalsT&Aarefortheexternal siren tamper. Tamper alarms that occur in the Day mode operate internal sounders only. Tamper alarms in Set cause a full alarm condition. Tamper is indicated by the Tamper TA indicator.
4 4188-753 issue 1_1/03
Engineering information
J2
PA
+
TAMP
-
+13V 0V
-
STROBE
J6
+-
AC
SW1
+
TA
SCB
DB
BELL
+
-
SET +ve
1A 1A 1.6A
BELL/STROBE
13V / SPEAKER
BATTERY
BATT
J4
F1F3F5
VR1
VOLUME
214
3
65
Factory fitted links
LD2 LD8 LD9 LD4 LD10 LD5 LD11
LD23
LD12
LD22
LD6
J1
LD3
SW2
WALK / ALARM TEST
TAMP
ON
OFF
ENTRY TIME
PART SET
15S
30S
Mounting holes
Mounting holes
Cable entry
holes
Danger
High Voltage
~
230V 50Hz 0.2A
FUSE T125mA 250V
(ANTI-SURGE)
Security zones
Note: The panel is supplied with wire links for unused zones. All unused zones must have links fitted to disable the zone.
It is recommended that no more than 10 magnetic contacts are connected to the same zone.
Logic Six intruder system
J2
214
3
65
Panel
Alarm
+-
PA
+
-
TAMP
+13V 0V
PIR
All unused zones must have links fitted to disable the zone.
Board
PIR
Door Contact
Door Contact
Terminal block is not supplied
Tamp
J1
PA circuit
Any quantity of normally closed type personal attack button may be wired in series and then connected to the PA circuit.
Operational in Day and Set, the PA circuit will cause a full alarm condition when activated. PA is indicated on the control panel as PA.
PA buttons may be fitted near the front door, or in a bedroom.
6 4188-753 issue 1_1/03
Engineering information
PA
+
-
TAM P
+13V 0V
Board
Panel
Panic Button
Panic Button
J2
214
3
65
J1
Extension speaker
Extension speaker may be connected to the loudspeaker terminals to produce high volume alarm tones and low volume entry / exit fault tones.
A 16 ohms extension speaker may be wired across the speaker terminals. Mounted in convenient position within the installation the extension speaker will reproduce all of the alarm tones generated by the control panel.
A control marked VOLUME in the centre of the board may be used to adjust the low volume entry/exit tones to suit environmental conditions.
Logic Six intruder system
-
STROBE
J6
+
TA
SCB
DB
BELL
+
-
SET
+ve
1A
BELL/STROBE
F5
Panel
Board
1A
13V SPEAKER
F3
16 Ohms Extension Speaker
VR1
VOLUME
External siren Output (Bell box)
The external siren (bell box) is usually installed in a high position from where the siren could be seen and heard.
Terminal TADBareforconnecting to the external siren. These terminals provide a power/hold-off supply, sounder trigger and tamper circuit to protect the external siren housing.
The terminals are summarised as follows: T - -Ve tamper return A - -Ve supply (0V) D - +Ve supply (12V) B- -Ve Sounder trigger For ease of installation, ADE external sirens and modules use the same markings. Where a discrete external siren is used, it should be connected to terminalsD&B.TerminalsT&A
are then used for tamper protection for the housing.
8 4188-753 issue 1_1/03
Engineering information
-
STROBE
J6
+
TA
SCB
DB
BELL
+
-
SET
+ve
1A
BELL/STROBE
F5
Sonade
Panel
Board
+- TEADB
STROBE
Where self contained / powered sounders are used, carefully follow the manufacturers instructions, match each of the terminals to those above.
13V Supply output
The 13V output is to power detectors which require a voltage supply (PIR detectors etc). The supply is present at all times and may be used to supply a total load of 350mA.
Set +VE
The output , marked SET +VE is used with latching detectors. The output becomes positive on correct Set of the system and is removed on UNSETTING the system.
Logic Six intruder system
# Terminal block is not supplied
-
STROBE
J6
+
TA
SCB
DB
BELL
+
-
SET +ve
1A
BELL/STROBE
F5
Sonade
Panel
Board
+- TEADB
STROBE
#
Sonade
+- TEADB
STROBE
Factory set condition
Keyfob 1 and 2 (supplied) - Learnt Keyfobs 3 to 8 (optional) - - Require learning External siren Bell Duration 20 minutes External siren Bell Delay - - No delay
Full Set
Zone1 ---------Timed Zone 2 ---------Time inhibited Zone 3, 4,5&6 ----Immediate Entry time (timed zone)- 30seconds(default)
(15 seconds via setting DIP switch)
Exit mode is timed - - - 30 seconds
Part set (DIP switch selectable see page 12)
Zone 1,2&3 -----Timed Zone 4 ---------Immediate zone Zone5&6-------Omitted zones Entry time (timed zone)- 30seconds(default)
(15 seconds via setting DIP switch)
Silent Exit mode is timed 30 seconds
Applicable for both full and part set:
Tamper TA 24 hour alarm Personal Attack PA 24 hour alarm Security Zones -------Zones 1…6 Zone debounce period - - - 640mS ALL zones
Zone Function
The following are definitions of zone functions:
Timed : This function would be used to protect the main entry/exit door of the entry route.
Time inhibited (Walk through) : This is a zone which, on setting the panel, allows access to the Entry / Exit zone. However, if the panel is set and an time inhibited zone is triggered before an Entry /Exit zone then an alarm will be generated immediately.
Immediate: This is a zone which will, when entered, go into alarm when the panel is set.
The Entry deviate feature permits an immediate zone to be activated during the entry period without causing a full alarm.
Unused : An unused zone that has been linked out will be ignored by the panel.
10 4188-753 issue 1_1/03
Engineering information
First Power up
Before power up fit the top cover on to the base and connect the speaker wires. Leave the cover in position throughout the reset of the installation.
a.
Check that the factory fitted links are connected to terminals unused Zones, PA, TAMP and T-A.
b. Fit the battery wires to the BATT
terminals on the Board, Red to + and Black to -.
c. On connecting the battery the system
will now go into alarm condition, the Tamper LED is lit and the Power LED gives a flashing indication:
d. Fit the cover to hold down the tamper
spring at the bottom centre of the board.
e.
Offer a keyfob to the centre depression on the panel. Note the Tamper LED and Alarm switches Off and the
LED is lit.
Note: If you do not withdraw the keyfob after it is recognised by the panel then you run the risk of entering an undesired mode of operation.
Mains Connection
The mains power should be connected using a 3 core cable of not less than 0.75mm sq. from a
fused spur to the mains connector inside the control panel. The 2 A fused spur must be located close to the control panel.
Note: The mains supply must be connected by a technically competent person and according to current IEE regulations.
Caution: To avoid the risk of electrical shock you must always totally isolate the mains supply before opening the control panel cover(s).
ÿ
Mains Input Fuse rating: 125mA, 250V type T (anti surge) and of a type approved to IEC 127 part 2 sheet III.
On connecting the mains supply to the panel the power indicator is lit.
(Changes from flashing to steady)
4188-753 issue 1_1/03 11
Logic Six intruder system
N
L
E
Transformer
125mA Fuse
Panel
+-
AC
1.6A
BATTERY
BATT
J4
F1
Board
(red)
+
Black -
12V battery
TA
Alarm
Power
Offer keyfob to the Panel and withdraw
Keyfob recognition beep
Accenta
/!
mini
1 2 3 4 5 6TAPA
ZONE
Learn
Error
Day
Power
N
L
E
Transformer
125mA Fuse
Panel
+-
AC
1.6A
BATTERY
BATT
J4
F1
Board
(red)
+
Black -
12V battery
2A Fused Spur unit
Dedicated mains supply
from consumer unit.
Day
Power
Testing the system
Complete the wiring of the system and then:
ÿ
Program the panel.
ÿ
Fully test the system and ensure it is fault free
ÿ
Fill in the installation log at the back of this manual and retain if for future reference.
ÿ
Finally explain the operation of the system to the end user. The Operating Instructions
are attached to the centre of this manual. Detach them and leave them with the user.
Key
System indications
- Unset system indication
- Set system indication
Note: The Power LED will give a flashing indication when there is a mains supply failure to the panel.
Programs
The panel offers Full Set or selectable Part Set routine and programmable entry time. As default the panel is set for Full Set and an Entry time of 30 seconds.
ÿ
Full Set : Arms all of the zones and become Set as the user leaves the property after the Exit time of 30 seconds.
ÿ
Part Set : To protect the downstairs areas of the house at night the Zones 5 and 6 are omitted from being set as the user goes upstairs after the Exit time of 30 seconds.
Note: The Part Set assumes Zone 5 and Zone 6 are upstairs zones.
ÿ
Entry time 30 seconds (factory default): Allows the user to enter the premises and unset the system within 30 seconds.
ÿ
Entry time 15 seconds : Allows the user to enter the premises and unset the system within 15 seconds.
12 4188-753 issue 1_1/03
Engineering information
Powe
r
Day
Powe
r
LED steady On indication
LED Off
Strobe
External Siren
NOTE: In general a flat beep is an indication of not recognised keyfobs.
Sound description
Internal sound
External devices
LED flashing indication
J6
ON
OFF
ENTRY TIME
PART SET
15S
30S
Board
Panel
Walk tests
The walk test function allows each detector to be checked in order to verify that they are functioning correctly.
To enter walk test the panel must be in Day
mode with the DAY LED lit:
a. Open the bottom cover of the panel.
Note this will cause a tamper alarm.
b. Present a recognised keyfob and the
alarm sound stops. Tamper TA LED will flash to give a tamper indication.
c. Momentarily press the PCB mounted
push button. Note do not hold the button down or it will go into Walk test.
The DAY LED starts to flash.
d. Upon activation of any zone, the
relevant ZONE led will latch up and a“Zone fault” tone is emitted.
e. Pressing the push button again at any
time will clear the latched LED and walk test is restarted.
f. On completion of Walk Test, close the
panel cover and an “OK” tone is emitted and the panel returns to Day
mode with the Day LED lit.
Alarm tests
The alarm test function allows you to test the Strobe, Siren (Bell), Low and High volume sounders of the system, SET+ output.
The Alarm Test mode could also be activated while in Walk Test mode, if you are doing this go straight to step d).
To enter Walk Test mode the panel must be in
Day mode with the DAY LED lit:
a. Ensure the bottom cover of the panel is
open. Note this will cause a tamper alarm.
b. Present a recognised keyfob and the
alarm sound stops. Tamper TA LED will flash to give a tamper indication.
d. Press the PCB mounted push button
and hold for 3 seconds.
e. The tests below are performed
consecutively. Automatic advance to the next test after 3 seconds.
1) Low Volume Sounders
2) High Volume Sounders and Strobe
3) External Bell and Strobe
4) SET+ output and Strobe
f. On completion of Alarm Test an “OK
tone is emitted and the panel returns to
Day mode with the DAY LED lit. Close the bottom cover of the panel and the Tamper TA LED switches Off.
4188-753 issue 1_1/03 13
Logic Six intruder system
Board
Panel
SW2
WALK / ALARM TEST
Board
Panel
SW2
WALK / ALARM TEST
How to learn new keyfobs
14 4188-753 issue 1_1/03
Engineering information
Offer a slightly touch it on the centre depression of the A learnt indication is given of the when the flashing LED changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered LED will start flashing. Withdraw the learnt keyfob.
You now have up to 10 seconds to learn another new keyfob.
For keyfobs 7 and 8 the indications are TA and PA LEDs respectively.
new keyfob
Panel. new keyfob
ZONE
ZONE
keyfob recognised beep
Panel
New keyfob
When an unrecognised keyfob is offered to the it will cause the
LED to be lit and a continuous sound is emitted from the
local sounder.
Hold the
The will timeout after 10 seconds if no action is taken to learn new keyfob
panel
Error
learn mode
recognised such that it touches the centre
depression on the Panel and keep it there without movement for
You will hear a keyfob recognition beep and
later five rapid beeps from the local sounder.
You are now in the The LED will give a flashing indication and the LEDs change from flashing to steady On indication to show recognised or . The is now ready to learn signalled by the next flashing LED. Withdraw the keyfob.
In the when an already learnt keyfob is offered to the an Error indication will be given.
‘learnt’ keyfob
learnt keyfob Panel
new keyfobs
Panel
,
10 seconds. 10 seconds
learn mode. Learn
ZONE
ZONE
learn mode
1
Repeat to learn the
Once all the keyfobs are recognised ‘learnt’ by the wait for just over 10 seconds for the Panel to exit the this is announced by two beeps from the local sounder and return to mode indication.
new keyfob.
Panel
learn mode,
Day
x 2 beeps
keyfob recognised beep
Panel
Learnt keyfob
x 5 rapid beeps
Hold for 10 seconds
Power
Day
Using a recognised the can learn further keyfobs. A total of 8 keyfobs are recognised by a Panel. You may want to do this if you have acquired additional keyfobs. Using these procedures the panel will still memorise previously learnt keyfobs. New k
learnt keyfob panel
eyfobs must be learnt by the .panel
Ensure the is in the day mode with the LED lit. You should have one and the new keyfobs available.
panel
learnt keyfob
Day
Indication given assumes 2 keyfobs were previously learnt by the Panel
32
1 42 3
Learn
Power
Day
Learn
How to re-learn all keyfobs
4188-753 issue 1_1/03 15
Logic Six intruder system
By entering the in this manner you will erase all recognition of previously learnt keyfobs at the Panel, except for the one used to enter the .
learn mode
learn mode
Offer the slightly touch it on the centre depression of the A learnt indication is given of the when the flashing LED changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered indicator will start flashing. Withdraw the learnt keyfob.
You now have up to 10 seconds to start learning another keyfob.
next keyfob Panel
.
next keyfob ZONE
ZONE
keyfob recognised beep
Panel
Next keyfob
When an unrecognised keyfob is offered to the it will cause the LED to be lit and continuous sound to be emitted from the local sounder.
Hold the
The will timeout after if no actions is taken to learn the next keyfob
Panel
Error
learn mode 10 seconds
recognised slighty touching the centre depression on the and keep it there without movement for . Initially you will hear a keyfob recognition beep and
later five rapid beeps from the local sounder. After another you will hear 5 rapid beep tone from the local sounder. You are now in the The LED will give a flashing indication and the LED changes from flashing to steady On indication to recognise the . The is now ready to learn the , signalled by the
LED flashing. Withdraw the learnt keyfob.
In the when an already learnt keyfob is offered to the
an Error indication will be given.
‘learnt’ keyfob
Panel
learnt keyfob
Panel next keyfob
Panel,
20 seconds
10 seconds
10 seconds
learn mode. Learn
ZONE 1
ZONE 2
learn mode
Repeat to learn the
Once all the keyfobs are recognised ‘learnt’ by the wait for just over 10 seconds for the Panel to exit the this is announced by two beeps from the local sounder and return to mode indication.
next keyfob.
Panel
learn mode,
Day
x 2 beeps
keyfob recognised beep
Panel
Learnt keyfob
x 5 rapid beeps
Hold for 20 seconds
Using a recognised the can re-learn up to 8 keyfobs. You may want to do this after a keyfob is lost or stolen and you want to prevent the use of it to operate the system.
learnt keyfob Panel
Keyfobs must
be learnt by each installed in a systemPanel
Ensure the is in the day mode with the LED lit. You must have one and up to 7 further keyfobs to be learnt. Have all the keyfobs available.
Panel
learnt keyfob
Day
x 5 rapid beeps
Power
Day
1 2 3
Learn
1 2
Learn
1 2 3
Learn
Power
Day
How to learn keyfobs if none are recognised
16 4188-753 issue 1_1/03
Engineering information
Offer the slightly touching it on the centre depression of the A learnt indication is given of the when the flashing LED changes to steady On indication and there is a recognition beep given by the local sounder. Shortly after the next numbered LED starts flashing. Withdraw the learnt keyfob.
next keyfob
Panel. next keyfob
ZONE
ZONE
You now have up to to learn the10 seconds next keyfob.
keyfob recognised beep
Panel
Next keyfob
Hold the slightly touching it on the centre depression of the .
first keyfob
Panel
Once the is acknowledged by the the LED changes from flashing to steady and there is a recognition beep given by the local sounder. Withdraw the learnt keyfob. The is now ready to learn the , signalled by LED flashing.
first keyfob Panel
Panel next keyfob
ZONE 1
ZONE 2
keyfob recognised beep
Panel
first keyfob
x 5 rapid beeps
Now remove the link between Z1 and Set.
x 2 beeps
Hold
Ensure the is connected to the intruder system and the link is fitted on the
Power up the intruder system you will hear five rapid beeps to acknowledge the is in the .
Panel
Panel PCB between Z1 and Set.
Panel Learn mode
The will NOT timeout until the first keyfob is learnt.learn mode
You will only need to learn keyfobs in this manner if no keyfobs are recognised by the
You must have all the keyfobs to be
learnt available. Keyfobs can be learnt by each installed in a system
Panel.
Panel
A can
learn up to 8 keyfobs following power up of the intruder system.
Panel
POWER UP THE SYSTEM
Power
Day
1
Learn
1 ZONE
-
STROBE
J6
+
TA
SCB
DB
BELL
+
-
SET
1 2
Learn
1
Learn
2 3
Repeat to learn the next keyfob.
Once all the keyfobs are recognised ‘learnt’ by the Panel wait for just over and the Panel will exit the10 seconds learn mode, this is announced by two beeps from the local sounder and return to Day mode indication.
NVM Error
A Non Volatile Memory NVM error indication is given by a flashing Error LED. If an NVM error occurs then you will need to re-learn all the keyfobs, see page 16.
Re-arm
After an alarm the panel will automatically reset itself when the external siren (bell box) 20 minute timer has expired.
Alarm Cycle Counter
An alarm cycle is considered as the duration of an alarm from trigger to the end of 20 minutes operation of the external siren. The panel allows three alarm cycles during either set or unset period. When the third alarm cycle expires the panel is shut down, the storobe continues to operate. The panel is unset in the normal way see operating instructions.
4188-753 issue 1_1/03 17
Logic Six intruder system
Faults
Fault conditions are often the result of minor installation errors or misinterpretation of the equipment being installed. The following points outline the most common installation and commissioning faults.
a.
If a tamper TA or Personal Attack PA fault is present on the system, a flashing indication is given of first fault, it will go to a lock out condition (showing the appropriate indication). Rectify the fault and offer the keyfob to the panel to remove the fault.
b. The most common cause of a zone not
responding to detection is incorrect wiring. Normally closed detectors must be wired together in a series loop before connecting into the appropriate ZONE terminals. Tampers are series wired in the same manner.
c. Where a permanent zone fault is
showing and the loop resistance is found to be in order, the most probable cause is a short circuit between the zone wiring and the tamper wiring. When measured with a multimeter the series resistance between the zone and tamper wiring should be infinitely high.
d. If totally lost as to the cause of a fault,
remove ALL wiring from the Board. Refit the 9-links and test the system. Never fit links to any positions other than those marked on the Board.
e. Before testing or replacing any fuses,
ALL power must be removed. Fuses which fail continually are almost certainly the result of a short circuit or low resistance across the 13V supply or external siren (bell box) supply (terminal D).
Whenever working close to the mains supply or connector, you should exercise extreme caution always isolate the mains supply before
removing the control panel covers.
Where normally open and closed detectors are being used these must be wired to a zone in the manner shown.
The example below shows how to wire normally open detectors on zones 3.
The example below shows how to wire normally open detector on zones 3 and a normally closed detector on zone 4.
f. Where Pressure mats are being used
these must be connected to a zone in the manner shown. The example below shows pressure mats connected to zones 3.
18 4188-753 issue 1_1/03
Engineering information
J2
214
3
65
PA
+
-
TAMP
+13V 0V
Board
J1
Panel
Normally open detectors
J2
214
3
65
PA
+
-
TAMP
+13V 0V
Board
J1
Panel
Normally open detectors
Normally closed detector
J2
214
3
65
PA
+
-
TAMP
+13V 0V
Board
J1
Panel
Pressure Mats
Specification
Indicators on Control panel
Zone 1-6 (red), Tamper ­TA (amber), Personal Attack-PA, Power, Learn (amber), Error (red) and
Day (green) 6 Zones +ve loop, Security zones Tamper -ve loop, always active PA +ve loop, always active User keyfobs Up to 8 keyfobs can be
learnt to operate with the
panel Keyfob operating
range
20mm nominal form
centre depression Proximity reader 125KHz inductive External siren
(Bell box) Output
12V, time 20 minutes
continuous Strobe Output 12V latching Extension Speaker
16 Ohms 260mA Exit time 30 seconds Entry time Programmable by DIP
switch 15 seconds or
30 seconds Full/Part Set Programmable by DIP
switch Walk and Alarm
Tests
Selectable by push
button switch Zone Input Delay 640mS Set +ve Output 0V in Day (sinking
40mA)
12V in Set (Sourcing
10mA) Current
Consumption Control panel
Standby 80mA
Alarm 250mA
Low voltage output
13.8V dc stabilised
(+/-5%) up to 350mA Rechargeable
Battery
12V, 1.2 or 2.1Ah
Charge Voltage 13.8V dc (+/-5%) Board Fuses 1.6A & 1A 20mm quick
blow Mains Input fuse 125mA, 250V type T
(anti-surge) type
approved to IEC 127,
part 2 sheet III
Total Current Output
1A when supported by a fully charged battery
Mains Supply Voltage
230V (+/-10%) 50Hz max load 0.2A
Ambient Operating temperature
0°C to 40°C
Enclosure construction
3mm Polycarbonate
Panel dimension H 200mm W 253mm
D 55mm
Keyfob dimension L 58.5mm W 18.5mm
4188-753 issue 1_1/03 19
Logic Six intruder system
Servicing organisation Details
Servicing organisation name:
_______________________________________ Telephone number:
______________________________________ Date of installation:
______________________________________ Account Number:
_____________________________________
Parts
Below is a list of approved parts and accessories.
LGSIX/01 Logic Six panel
(supplied with 2 learnt keyfobs)
SS/F Spare Keyfob
20 4188-753 issue 1_1/03
Engineering information
The Logic Six panel conforms to the requirements of the European R&TTE directive 1999/5/EC and carries the CE mark. This product is intended for use in the UK.
For Technical Support
: 01268 563270
ED&S The Arnold Centre Paycocke Road Basildon Essex SW14 3EA
Resistance Area protection and equipment used (eg PIR, Contacts..)
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Intruder alarm system
Operating Instructions
Servicing organisation details
Servicing organisation (Installer) name: ______________________________________________
Telephone number: _______________________________________________________________
Date of installation: _______________________________________________________________
Account number: _________________________________________________________________
1
Accenta
/!
mini
Learn
Error
Day
1 2 3 4 5 6
TA
PA
Power
ZONE
System installation
This booklet tells you how to operate your intruder alarm system. To simplify this booklet we have assumed that the alarm system has been installed by a professional intruder alarm system installer (the installer), and that the system is operated in a “typical” way. Aspects of your system that are not “typical” will be described by your installer.
Note: If you have any questions about
your intruder system, then consult your installer, see contact details on the front page.
Keyfobs
To operate the alarm system you will need the keyfobs supplied with the panel. These keyfobs are recognised by the panel and will operate your system. If you should need further keyfobs you should consult your installer, up to 8 maximum keyfobs can operate your system.
2
Operating instructions
Keyfobs Supplied with the panel
Additional keyfobs
Personal Attack
If you are under threat, or are being attacked, you can activate the alarm by operating the personal attack buttom in your system. The alarm system will produce a loud alarm sound, and the external siren will be turned on.
Power Indicator
The Power indicator on the control panel will light whenever the mains power supply is present. If mains power fails then the Power indicator will flash, but the system will run from its backup battery for several hours. If the Power indicator goes out when mains power is present then a fault may have developed on your system and you should contact your installer.
Key
3
Logic Six intruder system
LED steady On indication
LED Off
Strobe On
External Siren
NOTE: In general a flat beep is an indication of not recognised keyfobs.
Sound description
Internal sound
External devices
LED flashing indication
How to Set the system
When you leave your premises you will need to set (or turn on) the intruder alarm system. Before setting the system you should ensure that the premises have been completely vacated and that all doors and windows are closed. Ensure that pets do not have access to the protected areas as they can cause a false alarm, unless pet immune detectors have been used, ask your installer for more information.
4
Operating instructions
Panel
Offer keyfob to the Panel and withdraw
Keyfob recognition beep
The indicator should be lit at the Panel. Offer a to the Panel and withdraw it as soon as you hear the
from the local sounder.
The system will produce the exit beep tone and you should leave the premises by the exit route recommended by your installer. The system will set when the exit beep tone stops.
Day
keyfob
keyfob recognition
beep tone
Note the panel LEDs will flash consecutively from right to left, PA to Zone1 LED during Set operation. If however there is an open zone then the relevant ZONE LED will be lit and a sound indication is given. If this is the case then investigate the cause and ensure all zones are closed.
Insistent Exit beeps
(for final 10 seonds)
Once any operation is performed using the keyfob withdraw it away from the panel, wait for duration before next use of the keyfob to operate the system.
3 seconds
Power
Day
Power
The external strobe will operate for , which provides a confirmation of SET operation.
5 seconds
Exit beep
1 2 3 4 5 6TAPA
ZONE
How to Unset the system
When you enter your premises you will need to unset (or turn off) the system. If your system had gone into alarm then be aware that intruders may be in the premises. Seek assistance before investigating the cause of the alarm and unset the system.
5
Logic Six intruder system
Panel
Offer keyfob to the Panel and withdraw
Keyfob recognition beep
Enter your premises by the route recommended by your installer. The system will produce an entry beep tone.
Offer a to the Panel and withdraw it as soon as you hear the beep tone from the local sounder.
The system will stop the entry beep tone and light the green LED.
If any Zone, Tamper or Attack LEDs light up then an alarm has occurred, and an intrusion may have taken place. Seek assistance before investigating further as intruders may still be on the premises. The first alarm indication given by a flashing indicator, with all subsequent alarm indication given as a steady indication. These indications will remain until the next time the system is unset.
keyfob
keyfob recognition
Day
Note the panel LEDs will flash consecutively from left to right, from to the LED, during Unset operation.
Zone1 PA
Entry beep
Day
Power
n
Day
TA PA
Power
1 2 3 4 5 6TAPA
ZONE
How to part set the system
If your installer has programmed your system for part set operation you will be able to set some zones of the system while others remain unset. Part set operation is often used at night time, and it will permit you to freely walk around the bedrooms while the living area and outside doors are protected.
Before part setting the system at night time you should ensure the downstairs of the premises have been completely vacated and that all doors and windows are closed. Ensure that pets do not have access to the protected areas as they can cause a false alarm.
6
Operating instructions
Panel
Within10 seconds offer keyfob second time to the Panel and withdraw
Keyfob recognition beep
The indicator should be lit at the Panel. Offer a to the Panel and withdraw it as soon as you hear the
from the local sounder. Ensure ZONE 1 to ZONE 4 LEDs are Off. If they remain On, investigate the cause and ensure the zones are closed. The system will produce the exit beep tone. Within 10 seconds o
and you should
now move to area omitted by part set.
The system will set after 30 seconds when two consecutive beep is emitted.
Day
keyfob
keyfob recognition
beep tone
ffer a a second time to the Panel and withdraw it, you hear another
from the local sounder
The indicator should be flashing at the Panel.
keyfob
keyfob recognition beep
tone
Day
Exit beep
Once a any operation is performed using the keyfob withdraw it away from the panel, wait for 3 seconds duration before next use of the keyfob to operate the system.
Power
Day
Power
Panel
Offer keyfob to the Panel and withdraw
Day
2 x Set beep when panel is set
Entry time:________________
Area protected
Zone name Full set Part Set
Zone 1 T T
Zone 2 TI T
Zone 3 I T
Zone 4 I I
Zone 5 I O
Zone 6 I O
O = Omited T = Timed (Entry/Exit - Zone) TI = Time Inhibited (Access zone to keypad) I = Immediate (Zone armed to give full alarm)
7
Logic Six intruder system
8 4188-753 issue 1_1/03
Operating instructions
The Logic Six panel conforms to the requirements of the European R&TTE directive 1999/5/EC and carries the CE mark. This product is intended for use in the UK.