Walk tests
The walk test function allows each detector to be
checked in order to verify that they are
functioning correctly.
To enter walk test the panel must be in Day
mode with the DAY LED lit:
a. Open the bottom cover of the panel.
Note this will cause a tamper alarm.
b. Present a recognised keyfob and the
alarm sound stops. Tamper TA
LED will flash to give a tamper
indication.
c. Momentarily press the PCB mounted
push button. Note do not hold the
button down or it will go into Walk test.
The DAY LED starts to flash.
d. Upon activation of any zone, the
relevant ZONE led will latch up and
a“Zone fault” tone is emitted.
e. Pressing the push button again at any
time will clear the latched LED and
walk test is restarted.
f. On completion of Walk Test, close the
panel cover and an “OK” tone is
emitted and the panel returns to Day
mode with the Day LED lit.
Alarm tests
The alarm test function allows you to test the
Strobe, Siren (Bell), Low and High volume
sounders of the system, SET+ output.
The Alarm Test mode could also be
activated while in Walk Test mode, if
you are doing this go straight to step d).
To enter Walk Test mode the panel must be in
Day mode with the DAY LED lit:
a. Ensure the bottom cover of the panel is
open. Note this will cause a tamper
alarm.
b. Present a recognised keyfob and the
alarm sound stops. Tamper TA
LED will flash to give a tamper
indication.
d. Press the PCB mounted push button
and hold for 3 seconds.
e. The tests below are performed
consecutively. Automatic advance to
the next test after 3 seconds.
1) Low Volume Sounders
2) High Volume Sounders and Strobe
3) External Bell and Strobe
4) SET+ output and Strobe
f. On completion of Alarm Test an “OK”
tone is emitted and the panel returns to
Day mode with the DAY LED lit.
Close the bottom cover of the panel
and the Tamper TA LED switches Off.