LogicMark CaretakerSentry 40914 Installation Manual

Page 1
CaretakerSentry with two-way voice pendant
Quick Install Guide
Instructions for Installing Your New Personal Emergency Response System
LogicMark Disclaimers and Limited Warranty
COMMUNICATION AND RESPONSE LIMITATIONS: Purchaser acknowledges that signals which are transmitted over telephone lines, or other modes of communication pass through communication networks wholly beyond the control of LogicMark LLC and are not maintained by LogicMark LLC, and, therefore, LogicMark LLC shall not be responsible for any equipment or communication failure which prevents transmission signals from reaching your contact list including emergency 911 operators or damages arising therefrom. Purchaser acknowledges that LogicMark LLC provides no response to the System’s equipment. The equipment is designed to communicate with the a central station of your choice and LogicMark LLC is not and shall not be responsible for ambulance, police or other emergency response time or that any response will be provided by the central monitoring station.
TESTING AND SERVICE OF THIS EQUIPMENT: The equipment, once installed, are in the exclusive possession and control of the Purchaser, and it is Purchaser’s sole responsi­bility to test the operation of equipment and request warranty service if the equipment is under warranty.
PURCHASER’S EXCLUSIVE REMEDY: Purchaser’s exclusive remedy for LogicMark LLC’s default hereunder is to require LogicMark LLC to repair or replace, at LogicMark LLC’s option, any equipment or part of the personal emergency alert system which is non-operational during LogicMark LLC’s warranty period.
LIMITATION OF LIABILITY: This equipment is not designed or guaranteed to prevent any loss or injury. This Limited Warranty and Disclaimer of Liability constitutes the terms of sale and use of the equipment, and if there should arise any liability on the part of LogicMark LLC as a result of any cause whatsoever, regardless of whether or not such loss, damage, or personal injury was caused by or contributed to by LogicMark LLC’s negligence to any degree or failure to perform any obligation or strict products liability, such liability will be limited to an amount paid by the Purchaser to LogicMark LLC for the product, or to the sum of $350.00, whichever is greater.
For warranty information, see your dealer for details.
CaretakerSentry Base Unit - Model 40914
FCC ID: TYD-CS40914
IC: 8471A-CS40914
CaretakerSentry Two-Way Pendant - Model 41915
FCC ID: TYD-CS41915
IC: 8471A-CS41915
REN 3.7
Base Back View
Telephone Jacks
Line IN
To House Phone
Programming Switch
Programming Mode
“Emergency Call Mode”
Normal Operation
Reset
Power DC 7.5
800 mAh
Code Learn
(Red)
Cellular Accessory Jack
Base Side
View
CARETAKERSENTRY
© LogicMark, LLC v4.1
Pendant
Part #41915
Gray System Check/
Battery test button
Red Status LED
Microphone
Base Top View
Part #40914
Red Emergency
button
(Blue)
I(Green)
(Red)
Blue CareTaker
button
Microphone
(Yellow)
Speaker
Cancel (1 second)
Blue Emergency
call button
Pendant battery
cover latch
Pendant battery
compartment
Speaker
Backup Batteries
* Note Orientation
of batteries
Base Bottom View
Master
ON/OFF
Switch
Two-way Voice Pendant Battery
Charging Port (for optional Two-way
voice pendant accessory)
* Note Orientation of battery
Page 2
Plug Telephone Line and
Power Cord into Wall Jacks
3
CaretakerSentrStep-by-Step Installation
Place the Green AA Rechargeable Batteries in the compartment on the bottom of the base unit. Make sure to turn ON/OFF switch
to ON. You will hear the announcement “Running on Battery Power.” Unit will do so until the AC Adapter power supply is plugged in.
Place Batteries in Unit
2
Confirm Accessories in Kit
1
Plug the AC Adapter power cord into the power jack and twist 1/4 turn clockwise to lock.
4 Rechargeable AA
Batteries
Telephone Cord
AC Adapter
Lanyard
Test the Unit
4
Place call to Emergency Operator:
a. Push BLUE EMERGENCY button for 2 seconds on Pendant (RED LED
on the pendant should turn ON)
b. You should hear a dial tone, dialing and then communication tones
between the CaretakerSentry and central station. Several seconds later
the operator should answer the call c. Talk normally into the pendant– just like speaker phone d. At the end of the conversation, the CaretakerAlert should automatically
hang-up – if not, push the CANCEL button for 1 second (either on
back of pendant or on base unit.)
Performing a System Test
a. Push GRAY EMERGENCY button on back of pendant for 4 seconds b. Listen for voice prompt from base unit:
i. “All Systems are OK – Battery is OK” is heard if the system is correctly installed ii. If any other voice prompt is heard, the unit will describe the problem
c. We recommend that you perform this System Test weekly
Model #41911
(OPTIONAL) Plug the telephone into the “To House Phone” jack.
Install 2nd pendant battery into Two-way Voice Pendant Battery Charging port RED LED = Charging GREEN LED = Battery Charged No LED = defective battery or no battery installed
**Battery should standby in the pendant for 4-6 months (depending on use). We recommend to exchange/charge the batteries monthly.
Install 1st pendant battery in pendant. (When battery is properly installed, pendant will automatically perform a battery check - listen for these voice prompts everytime a battery is installed.)
2 Lithium Ion
Pendant batteries
*Beltclip*Wriststrap
*The holster is the same for both Wriststrap and Beltclip. Simply unscrew the strap and replace with the clip or vice-versa
CARETAKERSENTRY
Loading...