2 Megapixel High-resolution camera

Introduction
This manual contains technical documentation allowing easy installation and use of the
2-Megapixel CAM-200 camera module designed for the RTCU MX2 / DX4 series. For
information on the high-level programming of the CAM-200, please refer to the RTCU IDE
documentation.
The CAM-200 extends the capability of the RTCU platform with the ability to take JPEG
compressed snapshots. Snapshots can be taken in four different resolutions.
A whole new range of applications becomes available with CAM-200, such as:
• Remote monitoring of equipment, devices, work areas or locations.
• Any triggered event application.
• Security application.
• “A picture is worth a thousand words…”
Snapshots taken can either be saved to a SD-CARD, which can be accessed remotely, or
it can be sent directly over the network to a server.
Logic IO ApS. Ph: (+45) 7625 0210
Holmboes Allé 14 Fax: (+45) 7625 0211
8700 Horsens Email: info@logicio.com
Denmark www.logicio.com / www.rtcu.dk
Page 2 of 6

Table of Contents
Introduction ......................................................................................................................... 2
Table of Contents................................................................................................................ 3
Graphical view..................................................................................................................... 4
Installation........................................................................................................................... 5
MX2i Pro/Pro+ and DX4 Pro Connection......................................................................... 5
Lens adjustment .............................................................................................................. 5
Logic IO ApS. Ph: (+45) 7625 0210
Holmboes Allé 14 Fax: (+45) 7625 0211
8700 Horsens Email: info@logicio.com
Denmark www.logicio.com / www.rtcu.dk
Page 3 of 6

Graphical view
: Front and backside view
Logic IO ApS. Ph: (+45) 7625 0210
Holmboes Allé 14 Fax: (+45) 7625 0211
8700 Horsens Email: info@logicio.com
Denmark www.logicio.com / www.rtcu.dk
Page 4 of 6

Installation
MX2i Pro/Pro+ and DX4 Pro Connection
The CAM-200 is connected to serial port 1 (service port) on the RTCU MX2/DX4. For this
purpose a 3 meter cable is delivered, which also allows placement of the CAM-120 away
from the RTCU X32 unit itself.
Power supply for the CAM-200 is controlled by the RTCU unit. This keeps the power
consumption kept at a minimum, only turned on when taking snapshots.
Lens adjustment
After the CAM-120 is placed correctly, the focus needs adjustment. This is done by
loosening the screw that locks the lens and turning the lens carefully left or right manually,
depending on the distance to the objective to focus on.
Screw
Figure 2: Lens adjustment
Logic IO ApS. Ph: (+45) 7625 0210
Holmboes Allé 14 Fax: (+45) 7625 0211
8700 Horsens Email: info@logicio.com
Denmark www.logicio.com / www.rtcu.dk
Page 5 of 6

Technical specification
Still Image JPEG Compression VGA Camera ModuleCamera type
Still Image JPEG Compression VGA Camera ModuleCamera type
Resolution Up to: 1600x1200
Resolution
Up to: 1600x1200
2 Megapixel - 1/4 CMOSImage Sensor
2 Megapixel - 1/4 CMOSImage Sensor
AutomaticWhite Balance
AutomaticWhite Balance
AutomaticExposure
AutomaticExposure
AutomaticAuto Gain Control
AutomaticAuto Gain Control
MaximumTypicalMinimum
MaximumTypicalMinimum
3.3 3.53.0Power supply (VDC)
3.3 3.53.0Power supply (VDC)
120 (diagonal)90 (diagonal)Field of View (degrees)
120 (diagonal)90 (diagonal)Field of View (degrees)
+70 °C-15 °CWorking Temperature
+70 °C-15 °CWorking Temperature
Without mounting bracketW 36 x H 36 x D 29External Dimensions (mm)
Without mounting bracketW 36 x H 36 x D 29External Dimensions (mm)
Logic IO ApS. Ph: (+45) 7625 0210
Holmboes Allé 14 Fax: (+45) 7625 0211
8700 Horsens Email: info@logicio.com
Denmark www.logicio.com / www.rtcu.dk
Page 6 of 6