LockStateConnect LS-60 Operation Manual

PG 1
LS-60 Operation Guide
The LS-60 programmable communicating thermostat operates via a high-quality, easy-to-use touch screen. To program or adjust your LS-60, simply touch your finger firmly to the screen. The screen will automatically light up and you will hear a “beep.” Do not use a sharp
or metallic device; it will scratch the screen.
Statement of use: 100% Compatible with all popular
residential HVAC systems; 24VAC single, two stage conventional heating systems (gas/oil/electric), heat pumps, single stage or with auxilliary heat (electric or fossil), zoned forced air and zoned hot water (2 or 3 wire), millivolt systems (with a 12-24 AC or DC source), one or two stage cooling, and hybrid systems.
Save Energy button
Power Grid status indicator
top cover
Touch screen
Wire terminals
Mode button
Fan button
MENU butto
n
PROG butto
Reset button
HVAC selections switches
bottom
cover
DAY
F
LINK
RADIO
TARGET TEMP
1
COOL
A
U
TO
P
M
n
PG 2
Control Screens
HOME Screen
Before you operate the /6 please get familiar with these basic control screens. All the /6 functions are accessed through these screens: HOME, MENU, PROGRAM and MANUAL. The /6
touch screen technology allows you to select (by touching) an item and change it using the +/- arrows or the time arrows.
The HOME screen is displayed when the unit is operating. Touching the
HOME icon
on another screen
will always return you to this screen.
To set a Mode:
Press the mode button on the side.
The /6 will step through the
modes HEAT, OFF, and COOL in order. The LCD shows what mode
you are in.
DAY
F
LINK
RADIO
TARGET TEMP
1
COOL
AUTO
PM
Thermostat
Mode
Time of day
Current Room Temperature
Radio indicator
Lock status
Fan status
Time Slot
Target Temperature
Day
PG 3
MENU Screen The MENU screen is the gateway to many functions or settings of the
/6. It is displayed when you press the MENU button. [See page 10 for details]
Set Day
Touch this area to set
the day of the week.
Set Time
Touch this area to set
the time of day.
Left arrow goes back, right arrow goes forward.
Calibration control
Use this to calibrate your
LCD display match to
another thermometer.
Set
o
C -oF
Touch this to set temp display units.
Lock Program
Touch for 5 sec
to lock or unlock.
Filter Timer
set
Touch and hold
5 sec to change.
Chirp set
Touch this to turn the audible chirp on or off.
Temperature
Swing set
Differential to set
for 2nd Stage start.
Return to
HOME
screen.
HVAC SETUP
Touch this in OFF mode to
configure the unit to work with
your HVAC system.
DIFF
SWING
FILTER
F
HVAC SETUP
CALIBRATE
PG 4PG 4
PROGRAM Screen The stand alone PROGRAM screen sets the/6 control
for your home HVAC system with out a central controller. Press and hold PROG for 10 sec to access it. After that it is displayed when you press the PROG button.
[See page 8 for details]
PROGRAM
MORN
F
COPY DAY
HEAT
AM
Set Program Day
Touch this area to set the day of the week you want to program.
Set Time Slot
Touch this area to set the Time Slot you want to program.
Copy
Touch this area to copy current day’s program to the next day.
Return HOME
When programming is complete touch this to run your program and return to the HOME screen.
Set Program Time
Touch this area to set the
time of day you want each
time period to start.
Left arrow goes back, right arrow goes forward.
[Touch and hold for fast set.]
Temp Up / Temp Down
Touch these to raise and
lower each Target Temp.
[Touch and hold for fast set.]
PG 5
MANUAL Screen The Manual Screen control screen is where you can make
temporary changes to your /6’s operation. From the Full HOME screen, touch the main temperature display to use this screen. [See page 13 for details]
F
HOLD
EMER
HOLIDAY
HEAT
Target Temperature
Room Temperature
Return HOME
Temp Up / Temp Down arrows
Touch these to raise and lower the manual override Target Temp.
HOLIDAY
Touch this to invoke a
single program that repeats day
after day until you turn it off.
Manual Override Indicator
Shows TEMPORARY when you have modified the Target Temperature
EMER heat for HEAT PUMP systems.
TEMPORARY
HOLD Touch this area to operate the thermostat as
a manual thermostat. It will keep the temperature
you set until you change it or cancel HOLD.
PG 6
Simple HOME Screen Make this the default HOME screen for your
/6 by holding the PROG button for 12 seconds. This Simple HOME screen gives you limited access to the /6’s on screen display and no programming capability. It makes the /6 behave
like a simple one setting
thermostat.
The simple screen is useful for people who do not want a complex progam changing
their target temperatures each day. By simply using the Save Energy button these users can conserve energy and preserve
their comfortable temperature
settings.
F
LINK
RADIO
TARGET TEMP
1
COOL
Thermostat Mode
Current Room Temperature
Radio Indicator
Target Temperature
Temp Up / Temp Down
Touch these to raise and lower the Target Temp.
[Touch and hold for fast set.]
PG 7
Initial Settings
Press MENU to to access the following commands (from HOME screen).
Set day of the week
Touch the Day of the week area to cycle through the days of the week to select the current day.
Set time of day
Touch the Time of Day arrows to move the time selection forward or backward until it displays the current time. Touch and hold for faster setting.
Set oF-oC display
Touch the
o
F and it will toggle to
o
C.
Set audible chirp
Touch the musical note icon to select the chirp or no chirp.
Return HOME by touching the home icon.
ForwardBackward
PG 8
Auto-Run Program
The /6 comes pre-programmed with an EPA approved program. This program is recommended by
the EPA for energy efciency. We strongly recommend that you Auto-Run this program for one week, and see if it works for you. If it does not t your needs you can always input a custom program. To run the EPA program, set the mode switch to HEAT or COOL. Press the MENU button and use the arrows by the time display to set the time.
Touch the DAY area and advance it to select the present day. Touch HOME. The unit is now running the program.t
All Days 70oF 62oF 70o
6
2oF
MORN
6:00am
HEAT
DAY
8:00am
EVEN
6:00pm
NITE
10:00pm
All Days 78oF 85oF 78oF 82oF
MORN
6:00am
COOL
DAY
8:00am
EVEN
6:00pm
NITE
10:00pm
EPA
TO CHANGE THE PROGRAM:
Make sure the /6 mode is set to either HEAT or COOL, then press the PROGRAM button. This puts you at the PROGRAM screen [see page 4]. The programmed start time is displayed in the
upper left. The TIME SLOT icon indicates the active TIME SLOT in the default program [MORN, DAY, EVEN, NITE]. The programmed Target Temperature is shown on main display.
The HEAT program and the COOL program are separate.
PG 9
PROGRAM cont. Select the day you want to program.
The day of the week starts at SU - Sunday and can be advanced to the day you want to program. Touch the day of the week area to cycle through the days of the week to the desired day.
Select the time slot (period) you want to program (MORN, DAY, EVEN, NITE).
Touch the time slot area to cycle through to the desired period.
Select the desired start time of that time slot.
Touch the time arrows to select the desired period’s starting time. Hold arrow down for fast time
scrolling.
Select the desired target temperature for that time slot.
Touch the +/- arrows to select the desired period’s temperature.
To COPY one day’s programming to the next day, touch COPY DAY once. The information for the
current day will be copied to the next day which will appear on the screen. Holding down COPY for over 3 seconds will copy to all 7 days.
Touch
to return to the Home screen.
PG 10
MENU Screen Functions
Press MENU to bring up MENU screen.
TIME of DAY
Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per touch). Touch and hold the arrow for fast time set (15 minute jumps).
DAY of Week Touch DAY area to select present day. SWING (HVAC cycling rate) This feature allows you to set the desired variance in temperature
between the /6 setting and the room temperature required before the heating or cooling system
will turn on—from 0.5° to 2.0° F (.25° to 1° C). For example, if SWING is set to 2.0° F and the LS-60 is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F. Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then runs and will shut off at the Target Temperature.
To set SWING:
Touch SWING. Touch the left/right arrows to set the SWING from 0.5° to 2.0°F. The HVAC will run more frequently at .5°F and less at 2°F. Default is 1°F.
Touch
to return to the MENU screen.
Chirp set - Touch this to turn the audible chirp sound on or off.
PG 11
F C
Set - Touch this to switch the temperature display scale from
o
F to oC .
FILTER - AIR FILTER ALERT - The LS-60 can be programmed to remind you when the HVAC
sytem’s air lter needs changing. Touch FILTER. The display will show the usage to date. Touch FILTER for over 3 seconds and the display will change to LIMIT. Touch arrows to set desired usage limit before lter alert comes on home screen. When this limit is reached, FILTER will be on home screen and the CHECK FILTER indicator lights. Limit may be set from 0 to 999 days/99 weeks; default is 90 days/12 weeks. Touch to reset. To reset the usage back to 0, touch usage number; touching it again restores the displayed usage.
Touch
to return to the MENU screen.
LOCK (The LS-60 has 2 lock modes)
Touch
icon for 5 seconds; the unit will go into the PARTIAL lock mode. The user can temporarily
override the LS-60 target with the +/- buttons only. (1 bar) For FULL lock : Touch the
(1 bar) icon again for 5 seconds to go to full lock. No changes can be
made in full lock
(2 bars). Once locked, the LS-60 will respond just to mode and menu.
To UNLOCK , Press MENU.
Touch and hold
icon for 5 seconds for 2 bars (if not there already).
Then touch and hold the
icon for another 5 seconds.
Each 5 second touch and hold must be separate.
Touch to return to the Home screen.
PG 12
CALIBRATE
Your thermostat was accurately calibrated at the factory to ±1° F of actual ambient temperature. You do have the option, however, to change the display temperature to match that of a previous thermostat, or to match another thermostat already in your home. The range of change is from -6°F to +6°F or -3°C to +3°C.
To change your Thermostat Calibration, touch MENU and then touch CALIBRATE.
Use the + / - to adjust the displayed temperature up or down, as desired. The DELTA FACTOR that appears on the screen will also automatically increase or decrease for each 0.5° (F or C) adjustment so you can see your change. The large display will show the modied temerature reading that will be displayed on the HOME screen and used as the new room
temperature. Touch
to return to the Home screen.
DIFF (Used for 2 stage normal or heat pump with auxiliary only, not on screen for single stage)
The differential is the number of degrees between the room temperature and the Target Temperature at which the 2nd stage will be used. Default is 2°F. Touch MENU and then DIFF. Use the arrows to set the DIFF. Recommend 2°F for very cold climates and the 4°F for warm climates.
PG 13
MANUAL Screen Functions
The LS-60 has 4 manual override commands. The manual screen is accessed by touching the large
current temperature display in the middle of the HOME screen.
IMPORTANT: The Mode must be in HEAT or COOL to access the manual screen.
TEMPORARY override Touch the + / - arrows to select your desired temporary Target
Temperature. Touch HOME to return to operation. The TEMPORARY icon will display indicating
you have modied the Target Temperature for the current Time Slot only. It goes back to the
program target at the next period. Also, when in TEMPORARY, if the target is set the same as the programmed target for that period, the word TEMPORARY will go out.
HOLD
This will hold the target temperature you set indenitely, until you turn HOLD off. HOLD will allow
you to operate your thermostat as a manual thermostat. It will keep whatever temperature you set until
you change it or cancel hold. Take care using the HOLD function as the program is now bypassed. To set a hold target temperature, touch HOLD and use the +/- icons to select your hold temperature. The HOLD
icon will display on the HOME screen indicating you have changed the Target Temperature. The system
will HOLD this temperature until you return to the manual screen and de-select HOLD by touching it. Hold
is also canceled when you set the mode to OFF.
HOLIDAY This is a single program that repeats day after day until you turn it off. It supersedes the
PG 14
weekly program. To use it touch HOLIDAY on the temporary screen. The default holiday program is
shown below. To modify this program, touch the PROGRAM button and then touch the DAY area until HOLIDAY appears (after SAT). The default HOLIDAY program is set as 2 time slots; all day (same target MORN, DAY and EVEN) and a different target for NITE. [Default program: HEAT 70
o
F all day
and 62
o
F at night. COOL 78
o
F all day and 82
o
F at night.]
EMER (in HEAT PUMP type)
If you set your LS-60 for HEAT PUMP with auxiliary heat, EMER function is available on the MANUAL
screen. If you touch EMER, it displays EMER|ON. Your HEAT PUMP is disabled and auxiliary heat
is your sole source of heat. This manual override stays active until you toggle EMER off. Auxiliary heat is more expensive than the heat pump so use EMER only if the heat pump cannot keep up or is defective.
Other Functions
Save Energy Button
The “Save Energy” feature on the LS-60 provides a simple, easy-to-use way to help you manage your energy use. SAVE ENERGY automatically adjusts your Target Temperature up in COOL or down in
HEAT by 4
o
F. To use Save Energy, press the Save Energy button in the upper left corner of the unit. The screen will now read “Save Energy”. To return to normal operation, press the “Save Energy” button again. This is useful to save energy if you are gone for a short time.
PG 15
MODE Button
The mode button sets the LS-60 to HEAT COOL or OFF modes. Press it once to step to the next mode. If the LS-60 is in OFF and you want to return to the mode you were previously in, touch the
OFF indicator on screen.
FAN Button
The fan control is normally in AUTO mode, meaning that the fan operates automatically with the HVAC system and the thermostat. When the fan button is pressed the fan goes ON; the fan will run continuously in this manual override until switched back to AUTO by pressing the FAN button again.
[NOTE: Fan ON function is available in the OFF mode to allow simple ventilating.]
Simple Screen
This display mode limits the amount of information on screen and limits the functions to just the +/­arrows and the MENU button. Hold down the PROGRAM button for 12 seconds to access the limited display screen.
Hold down the PROGRAM button for 12 seconds to leave the limited display screen.
RESET button The RESET button re-boots the LS-60 processor. It does not effect the user
programs that have been stored in permanent memory.
PG 16
Compressor Protection The LS-60 has a minimum cycle time of 4 minutes to protect your
compressor in cool and in heat pump (if you have one). The Home screen will show a small clock and A/C during this time and the compressor will not come on until the 4 minute delay is over.
Communicating Thermostat
The LS-60 has 2 RTM-1 radio ports. These allow your thermostat to communicate with other systems.
Using USNAP Radios The USNAP ports allow you to connect
your LS-60 to a wireless network. This can give you access to your home’s HVAC system even when you are away. It can also give you access to web based efcient energy management sites that
can help you save money and protect the environment.
To Insert a USNAP radio module:
Power off the LS-60. Insert the radio module in either slot on the back of the LS-60. Power up LS-60.
To connect to a network follow the instructions that came with the
USNAP module.
USNAP port
USNAP radio
Caution
DO NOT INSERT or REMOVE USNAP radio
modules if power is ON. This can damage the
thermostat or radio modules.
Loading...