Lochinvar WHL085 User Manual

KNIGHT Wall Mount
HEATING BOILER
Submittal Sheet
WHN-Sub-04
KNIGHT® WALL MOUNT HEATING BOILERS
JOB NAME ______________________________________________________________________ LOCATION ______________________________________________________________________ ENGINEER____________________________________________________________________ WHOLESALER __________________________________________________________________ MECH. CONTRACTOR ___________________________________________________________ MODEL NO. _____________________________________________________________________ TYPE GAS ______________________________________________________________________ Btu/hr INPUT_____________________________________________________________________ Btu/hr OUTPUT___________________________________________________________________ NOTES
Smart System
> SMART SYSTEM Digital Operating Control
Multi-Colored Graphic LCD Display
with Navigation Dial and Soft Keys
> Three Boiler Setpoint Temperature Inputs
Plus Domestic Hot Water Prioritization
> Built-in Cascading Sequencer for up to 8 Boilers
Multiple Size Boiler Cascade Lead Lag Efficiency Optimization
Front End Loading Capability with Copper Fin II
> Outdoor Reset Control with Outdoor Air Sensor
Programmable for Three Reset Temperature Inputs
> Programmable System Efficiency Optimizers
Night Setback DHW Night Setback* Anti-Cycling Outdoor Air Reset Curve Ramp Delay Boost Temperature & Time
> Three Pump Control
System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Pump Control* Domestic Hot Water Pump
> Domestic Hot Water Prioritization
DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps
controlled by the Smart System
DHW Modulation Limiting
Separately Adjustable Space Heat/DHW Switching Times*
> Building Management System Integration
0-10 VDC Input to Control Modulation or Set Point 0-10 VDC Modulation Rate Output 0-10 VDC Input to Enable/Disable call for heat
> Access to BMS Settings through Graphic LCD Display > High-Voltage Terminal Strip
120 VAC / 60 Hertz / 1 Phase Power Supply
Three Sets of Pump Contacts
> Low Voltage Terminal Strip
24 VAC Device Relay Proving Switch Contacts Flow Switch Contacts Alarm on Any Failure Contacts Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts
Features
System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 VDC BMS External Control Contact 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Variable Speed System Pump Signal Input* 0-10 VDC Signal to Control Variable Speed Boiler Pump* Modbus Contacts
> Time Clock > Data Logging
Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts
> Maintenance Reminder
Custom Maintenance Reminder with
Contractor Contact Information
Installer Ability to De-activate Service Reminder
> Low-Water Flow Safety Control & Indication > Password Security > Customizable Freeze Protection Parameters
Standard Features
> ENERGY STAR Most Efficient Recognition > 95% DOE AFUE Efficiency > Modulating Burner with 5:1 Turndown
Direct-Spark Ignition Low-NOx Operation Field Convertible from Natural to LP Gas
> ASME Stainless Steel Heat Exchanger
30 psi ASME Relief Valve
> Vertical & Horizontal Direct-Vent
PVC, CPVC, Polypropylene or SS Venting up to 100 feet
> Smart System Control > Condensate Trap > Other Features
Automatic Reset High Limit Adjustable High Limit w/Manual Reset Boiler Circulating Pump Wall-Mount Bracket Zero Clearances to Combustible Materials 12-Year Limited Warranty
(See Warranty for Details
2-Year Parts Warranty
§
Optional Equipment
CON·X·US Remote Connectivity Modbus Communication Flow Switch Low-Water Cutoff w/Manual Reset & Test Alarm Bell Concentric Vent Kit SMART SYSTEM PC Software BMS Gateway to LON or BacNet Multi-Temperature Loop Contro Sidewall Vent Termination Floor Stand
Firing Codes
M9 Standard Construction M7 California Code
* Exclusive feature, available only from Lochinvar
§ WHN 55-285 only
KNIGHT Wall Mount Dimensions & Specifications
Knight Heating Boiler Dimensions and Specifications
Model Max. Min. *AFUE Capacity NET Number MBH MBH % MBH MBH
WHN055 55 11 95.0 51 44 WHN085 85 17 95.0 79 69 WHN110 110 22 95.0 102 89 WHN155 155 31 95.0 144 125 WHN199 199.9 40 95.0 185 161 WHN285 285 57 95.0 264 229 WHN399 400 80 94.4 377 328
Notes: Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models. *WHN399 value is Thermal Efficiency
Input Heating
A B C D E F G H I J K L M N O Gas Water Air Vent Shipping
33-1/4” 18-1/2” 16” 11-3/4” 10-1/2” 6-1/2” 4” 1-1/2” 3” 14-1/2” 5-3/4” 4” 3” 16-1/4” 5” 1/2” 1” 2” 2” 139 33-1/4” 18-1/2” 16” 11-3/4” 10-1/2” 6-1/2” 4” 1-1/2” 3” 14-1/2” 5-3/4” 4” 3” 16-1/4” 5” 1/2” 1” 2” 2” 142 33-1/4” 18-1/2” 19” 14-1/2” 10-3/4” 7-3/4” 7-3/4” 2-1/4” 10” 15-1/2” 5” 3-1/4” 3” 16-1/2” 2-3/4” 1/2” 1” 3” 3” 159 33-1/4” 18-1/2” 19” 14-1/2” 10-3/4” 7-3/4” 7-3/4” 2-1/4” 10” 15-1/2” 5” 3-1/4” 3” 16-1/2” 2-3/4” 1/2” 1” 3” 3” 166 33-1/4” 18-1/2” 19” 14-1/2” 11-3/4” 8” 8” 1-1/4” 10” 16-3/4” 4-3/4” 3-1/4” 2-3/4” 16-1/2” 3” 1/2” 1-1/4” 3” 3” 175 33-1/4” 18-1/2” 19” 14-1/2” 11-3/4” 8” 8” 1-1/4” 10” 16-3/4” 4-3/4” 3-1/4” 2-3/4” 16-1/2” 3” 1/2” 1-1/4” 3” 3” 184 35-1/2” 25” 21-3/4” 17-1/2” 12-1/2” 9-1/4” 9-1/2” 2-1/4” 13-1/4” 21-1/2” 9” 4-3/4” 4” 22-1/2” 3-3/4” 3/4” 1-1/2” 4” 4” 213
Conn. Conn. Inlet Size Wt. (lbs.)
Lochinvar, LLC
300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000
Lochinvar.com
9/15—Printed in U.S.A.