Lochinvar WBN051 User Manual

Page 1
CONDENSING RESIDENTIAL GAS BOILERS
CONTROL WITH ALL NEW, ADVANCED USER FEATURES
5 FLOOR-STANDING AND 5 WALL-MOUNT MODELS FROM 50,000 TO 285,000 BTU/HR
LESS THAN 20 ppm NOx
DIRECT VENT FLEXIBILITY TO 100 FEET
UP TO 98% EFFICIENCY IN LOW TEMP APPLICATIONS
up to 96%
AFUE Efficiency
knightheatingboiler.com
Page 2
HEATING BOILERS
Up to 96% DOE AFUE Efficiency
The Best You Can Buy Is
KNIGHT is recognized for its reliable, proven performance and high quality standards. Its award winning design assures contractors and home owners peace of mind and long term savings in operating costs.
Now, Lochinvar has raised the KNIGHT standard to even greater heights. The dramatically enhanced SMART SYSTEM™ control with color display gives installers and maintenance personnel a greater level of control than ever before. It's easier to access all the information they need to setup, troubleshoot and monitor all boiler functions. Additionally, two new cascading options allow the installer to fine-tune sequencing of multiple boiler installations.
More than ever, KNIGHT is the best choice for traditional hydronic space heating, radiant floor heating and domestic hot
water applications.
Now Even Better!
Wall-Mount Models
5 space-saving KNIGHT Wall-Mount Boilers are available from 50,000 to 210,000 Btu/hr.
HEATING BOILERS
Floor Standing Models
The KNIGHT Floor-Standing lineup features 5 small footprint models from 80,000 to 285,000 Btu/hr.
Knight XL Commercial
Need more BTU's? KNIGHT XL Commercial Boilers are available in 5 sizes from 399,000 to 800,000 Btu/hr. See KNIGHT XL literature for more details.
All KNIGHT Boilers meet or exceed the most stringent requirements, with less than 20 ppm NOx.
The KNIGHT Boiler has earned the ENERGY STAR, signifying that it has met strict energy­efficiency guidelines set by the EPA and U.S. Department of Energy.
Page 3
Refined Design Puts More Control and Information at Your Fingertips
The new SMART SYSTEM™ is the most advanced integrated boiler control on the market today.
Larger LCD Screen
Displays more information.
Soft Keys
For simple programming.
Navigation Dial
For fast transitions from screen to screen and easy adjustment of settings.
USB Port
USB port permits connection to a laptop computer. SMART SYSTEM PC software may be used to troubleshoot and program KNIGHT set date and time, monitor historical data, including faults, trends and energy consumption.
®
functions,
At-a-Glance Color-Coding
Blue Screen
Normal system operation.
Yellow Screen
Maintenance due - shows the installer’s name and number on the display.
Red Screen
Lockout mode - shows active fault and installer's name and number on the display.
New Selectable Cascade Options
When multiple KNIGHT boilers are installed together, the SMART SYSTEM built-in sequencer can be set for “Lead-Lag” cascade or “Efficiency Optimized” cascade operation.
Lead-Lag Cascade
Efficiency Optimized Cascade
The “lead” boiler modulates with demand to capacity. As demand increases, additional boilers fire and modulate to capacity. This continues, with additional boilers firing and modulating to capacity until all units are operating. Every 24 hours, the SMART SYSTEM automatically shifts the lead boiler role to the next in the sequence, distributing lead-lag runtimes equally.
This feature optimizes the modulation capabilities of the Boiler Plant while evenly distributing run time across all cascaded boilers. Every 24 hours the SMART SYSTEM automatically shifts the 1st boiler on role to the next in the sequence, distributing run time equally.
SMART SYSTEM Cascade option allows 2 - 8 boilers to be sequenced.
Page 4
Dial in System Performance
NEW! Compatibility with Copper Fin II Non-Condensing Boiler
Allows you to create a front end loading system.
NEW! Multiple Sized Boiler Cascade Control
KNIGHTS of one or more sizes can be combined into a single cascade to maximize turndown and meet minimum demands.
* Internal Cascading Sequencer with Multiple Programmable System Efficiency Optimizers
Fine-tune installations using Lead-Lag or Efficiency Optimization Cascade features.
* Controls up to Three Setpoint Temperatures
Allows three different temperature inputs to be controlled. Boiler can be run at the lowest temperature demand for optimal efficiency.
*
Outdoor Reset for Each Temp Loop
The boiler setpoint temperature responds to changes in outdoor air temperature. Outdoor temperature monitor guides the reset schedule to meet the load.
Night Setback
Program a heating loop temperature setback for any time of the day, each day of the week.
Domestic Hot Water Prioritization w/Pump Control
On DHW call, SMART SYSTEM overrides the outdoor reset and starts the DHW pump to the indirect water heater alternating to meet both heating and hot water demands.
* DHW Night Setback
Resets DHW setpoint to save water-heating energy during times of low or no usage.
*
Exclusive feature, available only from Lochinvar
* DHW Max Firing Rate
Allows you to limit the maximum percentage of firing rate when in DHW mode.
* Separately Adjustable SH/DHW Mode Switching Times
Allows controls to be tailored to meet system demand. Design system setup for flexibility.
Indirect Water Heater Zone Pump Control
All boilers in cascade can be used to meet DHW demand as well as satisfy building load.
System & Boiler Pump Controls
Provides power to system and boiler pumps on a call for heat. Programmable post purge allows pumps to operate after a call has been satisfied. Option for Continuous System Pump Operation.
* Pump Relay with Freeze Protection
Parameters adjustable by installer for flexibility in low-temperature applications.
* Installer Access to BMS and Ramp Delay Settings
Set up or change these parameters through the control
itself on the front of the boiler; no PC software required.
Low-Water Flow Indicator
Uses temperature differential to protect against low flow in heat exchanger by reducing modulation or forcing boiler shutdown.
Password Security
Allows only qualified personnel to access parameters
* Product Service Indicator
Program reminders for cycle count, operation hours or last service. Installer's name and number may be displayed.
Building Management Inputs & Outputs
Optional Modbus Capability
Allows boiler communication through Modbus protocol. Simplifies BMS/boiler interface for status monitoring.
0-10V Building Management System (BMS) Control Input
BMS-driven input for modulation rate or temperature control.
0-10V Cascade Setpoint and Modulation Control
BMS-driven input for modulation rate or temperature control of cascade.
0-10V Heat Demand Input
Enables thermostat or a 0-10V signal to initiate a call for heat. Gives the BMS options on how to enable boiler or cascade.
0-10V Boiler Rate Output
Signal output of modulation rate allows BMS to monitor boiler firing rate.
0-10V Pump Signal Input
Input from variable speed system pump allows faster reaction to changes of flow in system, reducing possibility of temperature over-shoot and cycling.
0-10V Signal to Control Variable Speed Boiler Pump
Allows control to maintain a higher T at low firing rates and reduces boiler flow when it responds to lower flow rates in the system loop.
5 Flexible Options for Direct-Venting up to 100 Feet!
Placement of units within a building will never be a problem with KNIGHT. It permits up to 100 feet of air intake and 100 feet of exhaust vent with 3" PVC, CPVC, polypropylene or stainless steel pipe. Three Wall-Mounted
models (WBN 51 -106) also permit intake and vent runs up to 40
KNIGHT feet using 2" pipe.
Factory Supplied and Shipped with Every Model
Direct-Vent Vertical Vertical with Sidewall Air Direct-Vent Vertical* Direct-Vent Sidewall* Direct-Vent Sidewall
*An optional concentric vent kit is sold separately to allow a single penetration for both combustion air and vent pipes.
Sidewall Vent Termination
Page 5
State-of-the-Art Modulating Combustion System
c Hot Water Prioritization feature means
nsta
t with Lochinvar’s SQUIRE
indir
t
correct volume of fuel and air entering the burner.
ustion with 5:1
e fire
in
a
60
°
ge
r
ot require s
KBN286 Shown
Advanced Negative Regulation Technology
KNIGHT safely and reliably operates with supply gas pressures as low as 4 inches water column. Plus “Neg/Reg” technology
automatically adjusts gas pressure to ensure the correct volume of fuel and air entering the burner.
Direct-Spark Ignition
With each call for heat, two electrodes ignite the fuel/air mixture. A third electrode
then senses for flame. The SMART SYSTEM will generate a soft lockout and
display a fault if ignition does not occur after 3 attempts.
Fully Modulating Burner with 5:1 Turndown
The SMART SYSTEM allows fully modulating combustion with 5:1
turndown. The burner can fire as low as 20% of maximum input
and modulate the firing rate up to 100% as demand increases.
A woven stainless steel mesh enclosed burner tube fires in a 360°
pattern along the entire length of the primary heat exchanger.
Two-in-One Stainless Steel Heat Exchanger
A primary heat exchanger combined with a secondary heat exchanger
captures flue gas heat and condenses to utilize available latent
energy. The stainless steel, pH-tolerant design features a weld-sealed
assembly with no O-rings or gaskets and does not require special
glycol. ASME Section IV approved and stamped.
Field Connection Versatility
User-friendly terminal strip allows for 44 low-voltage field connections.
Four-line voltage connections supply power to the unit and up to three
pumps operated by the SMART SYSTEM.
Team KNIGHT with SQUIRE for low-cost domestic hot water!
KNIGHT’s Domestic Hot Water Prioritization feature means
you can easily install it with Lochinvar’s SQUIRE
water heater, available in 30, 40, 50, 65, 80 and 119
gallons. This combination will give homeowners high-
efficiency space heating from KNIGHT, and abundant
domestic hot water from SQUIRE. With a stainless steel
tank and heat exchanger, SQUIRE provides more hot water
and lower water heating costs than standard gas or electric
water heaters.
KBN286 Shown
®
indirect
Page 6
Knight
Models: KBN 081-211
®
®
Boiler Dimensions and Specifications - Floor-Standing Models Wall-Mount Models
3)$%
Models: WBN051-211
Model: KBN286
Knight Heating Boiler Dimensions and Specifications
Input Heating NET Model Min. Max. AFUE Capacity I=B=R Number MBH MBH % MBH MBH
WBN051 10 50 95.3 45 39 WBN081 16 80 95.3 72 63 WBN106 21 105 95.4 94 82 WBN151 30 150 95.5 135 119 WBN211 42 210 95.7 190 165 KBN081 16 80 95.3 72 63 KBN106 21 105 95.4 94 82 KBN151 30 150 95.5 135 119 KBN211 42 210 95.7 190 165
KBN286 57 285 96.0 260 226
Notes: Indoor installation only. All information subject to change. Change "N" to "L" for LP gas models.
Smart System™ Features
> SMART SYSTEM Digital Operating Control
> Multi-Color Graphic LCD Display
with Navigation Dial and Soft Keys
> Three Setpoint Temperature Inputs > Built-in Cascading Sequencer for up to 8 Boilers
> Cascade Multiple Sized Boilers > Lead Lag > Efficiency Optimization
> Outdoor Reset Control with Outdoor Air Sensor
> Programmable for Three Reset Temperature Inputs
> Programmable System Efficiency Optimizers
> Night Setback w/Overide Function > DHW Night Setback w/Overide Function > Anti-Cycling > Outdoor Air Reset Curve > Ramp Delay > Boost Temperature & Time
> Three Pump Control
> System Pump with Parameter for
Continuous Operation
> Boiler Pump with Variable Speed Pump Control* > Domestic Hot Water Pump
> Domestic Hot Water Prioritization
> DHW tank piped with priority in the boiler loop > DHW tank piped as a zone in the system with
the pumps controlled by the Smart System
> DHW Modulation Limiting > Separately Adjustable SH/DHW Switching Times*
> Building Management System Integration
> 0-10VDC Input to Control Modulation or Set Point > 0-10VDC Modulation Rate Output > 0-10VDC Input Signal from Variable
Speed System Pump*
> 0-10VDC Input to Enable/Disable call for heat
*Exclusive feature, available only from Lochinvar
A C D E F G H I J K M Gas Water Air Vent Shipping Conn. Conn. Inlet Size Wt. (lbs.)
29-1/4" 15-3/4" NA 10-3/4" 10-3/4" 2" 6-3/4" NA 3-1/4" 4-1/4" 2-3/4" 1/2" 1" 2" 2" 130 29-1/4" 15-3/4" NA 10-3/4" 10-3/4" 2" 6-3/4" NA 3-1/4" 4-1/4" 2-3/4" 1/2" 1" 2" 2" 130 29-1/4" 15-3/4" NA 10-3/4" 10-3/4" 3-1/2" 5-1/2" NA 3-1/4" 4-1/4" 2-3/4" 1/2" 1" 2" 2" 134 29-1/4" 20-3/4" NA 15-3/4" 8-1/2" 3-1/2" 5-1/2" NA 8-3/4" 9-3/4" 1-1/2" 1/2" 1" 3" 3" 162 29-1/4" 25" NA 20" 12" 3-1/2" 5-1/2" NA 13" 14" 1-1/2" 1/2" 1" 3" 3" 177 33-1/4" 14" 7" 5-3/4" 5" 3" 20-1/2" 22" 1-3/4" 6-1/2" NA 1/2" 1" 3" 3" 125 33-1/4" 14" 6-1/2" 5-3/4" 4-1/2" 1-1/2" 20-1/2" 22" 1-3/4" 6-1/2" NA 1/2" 1" 3" 3" 129 33-1/4" 18" 12-1/4" 11-1/2" 10" 1-3/8" 21-1/4" 23" 1-3/4" 12" NA 1/2" 1" 3" 3" 157 33-1/4" 22-1/4" 16-1/2" 15-3/4" 14-1/4" 5-1/4" 21-1/4" 23" 1-3/4" 16-1/4" NA 1/2" 1" 3" 3" 172
42-1/4" 19-3/4" 12-3/4" 13-1/2" 6" 2" 34" 31" 11-3/4" 4-1/4" NA 3/4" 1-1/4" 4" 4" 224
> High-Voltage Terminal Strip
> 120 VAC / 60 Hertz / 1 Phase Power Supply > Three Sets of Pump Contacts
> Low Voltage Terminal Strip
> 24 VAC Device Relay > Proving Switch Contacts > Flow Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > DHW Thermostat Contacts > 3 Space Heat Thermostat Contacts > System Sensor Contacts > DHW Tank Sensor Contacts > Outdoor Air Sensor Contacts > Cascade Contacts > 0-10VDC BMS External Control Contact > 0-10VDC Boiler Rate Output Contacts > 0-10VDC Variable Speed System Pump Signal Input
> 0-10VDC Signal to Control Variable
Speed Boiler Pump
> Modbus Contacts
> Time Clock > Data Logging
> Hours Running, Space Heating > Hours Running, Domestic Hot Water > Ignition Attempts > Last 10 Lockouts
> Access to BMS Settings through Graphic LCD Display > Maintenance Reminder
> Custom Maintenance Reminder with Contractor Info > Installer Ability to De-activate Service Reminder
> Low-Water Flow Safety Control & Indication > Dual Level Password Security > Customizable Freeze Protection Parameters
H
C
O
L
L
E
B
A
N
O
N
A
V
R
N
I
,
L
L
C
E
E
S
S
E
N
N
,
E
T
Patent Pending
4/0
"/44/-
Standard Features
> Energy Star™ Qualified > Up to 96% DOE AFUE Efficiency > Modulating Burner with 5:1 Turndown
> Direct-Spark Ignition
> Low-NOx Operation > Field Convertible from Natural to LP Gas
> ASME Stainless Steel Heat Exchanger
> 30 psi ASME Relief Valve
> Vertical & Horizontal Direct-Vent
> PVC, CPVC, Polypropylene or SS Venting up to 100 feet
> Factory Supplied Sidewall Vent Termination
> Smart System Control > Condensate Trap > Other Features
> Automatic Reset High Limit > Adjustable High Limit w/Manual Reset > Boiler Circulating Pump > Adjustable Leveling Legs (KB Models only) > Wall-Mount Bracket (WB Models only) > Zero Clearances to Combustible Materials > 12-Year Limited Warranty (See Warranty for Details)
Optional Equipment
> Modbus Communication > Condensate Neutralization Kit > Multi Temperature Loop Control > Flow Switch > Low-Water Cutoff w/Manual Reset & Test > Alarm Bell > Concentric Vent Kit > SMART SYSTEM PC Software > Stack Frame
> BMS Gateway to LON or BacNet
Firing Codes
> M9 Standard Construction
> M7 California Code
300 Maddox Simpson Parkway, Lebanon, TN 37090 | 615-889-8900 | fax: 615-547-1000 | www.Lochinvar.com