Lochinvar VAL30000 User Manual

Non-Condensing Boiler Protection for Low Temperature Systems
Ideal for use with Copper-Fin, Copper-Fin II, Power-Fin and Solution Boilers
When designing a boiler system with return water temperatures below 140°F it is necessary to protect the boiler from flue gas condensation. All non-condensing boilers will develop operational problems if they are continually exposed to system return water temperatures below 140°F. Typical systems that require this protection are water source heat pump systems,in-floor radiant heat systems, greenhouse heating, soil heating, process operations and manufacturing operations. Aditionally, heating systems that utilize nighttime setback, night/weekend shutdown or outdoor reset control strategies should incorporate low water temperature protection.
LTV Low Temperature Valves
To prevent low return water temperatures to the boiler and combat operational problems, the system should be piped in a primary secondary piping arrangement with a low temperature bypass. Manual bypass systems however are not the ideal solution due to varying flow rates and firing rate of the boiler. A better alternative is Lochinvar’s Low Temperature Valve, which is a self-contained automatic thermostatic 3-way valve that ensures temperatures entering the boiler remain above 140°F.
The Lochinvar LTV Low Temperature Valve is shipped separately and can easily be incorporated into the field installed primary/secondary boiler piping. (2” LTV Valve shown installed on CHN751)
Standard Features
Low Return Water Temperature Boiler Protection
Non-Adjustable and Automatic
Replaceable Thermostatic Element(s)
How it Works
The LTV Valve “modulates” to maintain 140°F as a minimum return temperature to the boiler.
- Hot water from the boiler enters “B” port.
- Cooler water from the system enters “C” port.
- “B” and “C” water mix to meet the desired 140°F.
- Water exits “A” port back to the boiler return.
1-1/2” LTV Valve
2” LTV Valve
2-1/2” LTV Valve
LTV Valve Dimensions & Spec i fi ca tions
1-1/2” LTV ValveU
Up to 55 GPM flow rate
Part Number - VAL30000
2” LTV Valve
Up to 55 GPM flow rate
Part Number - VAL3048
TYPICAL PIPING
All boilers must use optional remote sensor. Minimum high limit setting is 205°F. Pump supplied by installer.
2-1/2” LTV Valve
Over 55 GPM flow rate
Part Number - VAL3047
Note: Mounting flange Included with valves.
2-1/2” LTV Valve
Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
LTV-05 (Replaces LTV-04 6/08)
2” LTV Valve
1-1/2” LTV Valve
2-1/2” LTV Valve
www.Lochinvar.com