Lochinvar LTA040KDEF User Manual

Residential Electric
Tall and Short Models
Lochinvar’s residential electric water heaters are available in tall models from 30 to 120 gallons and short models from 30 to 50 gallons. Various combinations of elements, wiring and voltages can be furnished to meet most applications. Every unit features a sophisticated design for high efficiency, low standby loss, high first hour delivery and money saving performance. All water heaters are triple tested during fabrication to ensure the highest standards of quality and performance for a long service life.
Non-CFC Foam Insulation - Superior material formulation
provides uniform tank coverage with a thick blanket of insulating foam. This non-CFC polyurethane closed cell foam minimizes standby losses and maximizes heat retention.
Immersion Type Heating Elements - copper sheath design for
longer life in hard, aggressive water.
Screw-In Element Mounting - for easy replacement
and service.
Adjustable Thermostat - This accurate control provides an easy
way to reset water temperature for best economy. An automatic over-heat safety device is standard.
Glass-lined Steel Tank - The durable glass lining is fused to the
tank at 1600°F to assure lasting protection against rust and corrosion while providing clean, clear hot water. 300 psi test pressure provides 150 psi working pressure.
Tank Saver Anode - A large diameter, high capacity anode inhibits
corrosion of the tank interior for long, trouble-free service.
Heat Trap - The heat trap protects from heat loss through the water
piping.
Temperature & Pressure Relief Valve - Factory installed.
Brass Drain Valve
6- Year Limited Tank & Parts Warranty* – See warranty for
details.
10-Year Extended Warranty Available – Residential
applications only
* 1-year limited tank & parts warranty when installed in a commercial application.
Water Heaters
Optional Features
Voltages Available—120, 208, 240 volts.
(Wired for single phase only)
For 277, 380, 415 & 480 volts, and all 3ø see Light Duty Commercial Water Heaters
All models meet or exceed the NAECA and ASHRAE Energy Efficiency Standards
Dimensions and Specifications
3/4 OUTLET
3/4 INLET
B
8"
TOP VIEW
A
C
FRONT VIEW
Model Gal. Input 1st Hour Energy Shipping Number Cap. Watts Rating Factor A B C Weight
Short Models LSA030KD 30 4500 41 .93 30” 22” 22-1/2” 91 LSA040KD 40 4500 38 .92 31-1/4” 23” 24-3/4” 113 LSA050KD 50 4500 55 .91 34” 26-1/2” 25” 164 Medium Models LMA030KD 30 4500 43 .93 36-1/2” 20-1/2” 28” 90 LMA040KD 40 4500 52 .92 44” 20-1/2” 37-3/4” 103 LMA050KD 50 4500 60 .90 48” 21-1/2” 40-1/2” 121
Tall Models
LTA030KD 30 4500 43 .93 46-1/2” 18” 39-1/2” 90 LTA040KD 40 4500 52 .92 59-1/2” 18” 53-1/2” 106 LTA052KD 50 4500 60 .91 54” 20” 47-1/2” 116 LTA066KD 66 4500 72 .88 60-1/4” 20-1/2” 53” 178 LTA082KD 80 4500 81 .86 60-1/2” 22-1/2” 52” 208 LTA120KD 119 4500 112 .81 64-1/4” 28” 54-1/4” 336 High Efficiency Models LMA050KDEF 50 4500 62 .93 49” 23” 40-1/2” 155 LTA040KDEF 40 4500 54 .93 60” 19” 53-1/2” 120 LTA052KDEF 50 4500 60 .93 56-1/2” 21-1/2” 47-1/2” 135 LTA066KDEF 66 4500 76 .92 61” 23” 53” 180 LTA082KDEF 80 4500 87 .93 61-1/2” 25” 52” 210
Notes: Total amperage not to exceed 48 amps. Standard Voltage and Wattage: 240v – 4500w.
FOR EASE IN ORDERING
BY MODEL NUMBER
L T A 040 K D
MODEL
TALL
VOLTAGE
This heater has a 6 year warranty. It is a tall model, has a 40 gallon capacity with a 240 volt 4500 watt upper
element and 4500 watt lower element.
HEATING ELEMENT
SCHEDULE
C - 1500 D - 1650 J - 4000 F - 2500 K - 4500 G - 3000
ELEMENT WATTAGE
CAPACITY
TANK
ELEMENT QTY
VOLTAGE SCHEDULE
C – 120V 1ø J – 208V 1ø A – 240V
N - 5500 H - 3500 P - 6000
RECOVERY RATE
Recovery Rate (GPH)
Element Wattage 40°F 50°F 60°F 70°F 80°F 90°F 100°F
C 1500 16 12 10 9 8 7 6 D 1650 21 17 14 12 10 9 8 F 2500 26 21 17 15 13 11 10 G 3000 31 25 21 18 16 14 12 H 3500 36 29 24 21 18 16 14 J 4000 41 33 28 24 21 18 17 K 4500 47 37 31 27 23 21 19 N 5500 52 41 34 30 26 23 21 P 6000 62 50 41 35 31 28 25
Certified for Potable Water and Space Heating Applications
This water heater is suitable for water heating and space heating. Toxic chemicals, such as those used for boiler water treatment shall NEVER be introduced into this system. This water heater may NEVER be connected to any existing heating system or components previously used with non-potable water heating appliances.
Lochinvar, LLC • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax 615-547-1000
RE-18 (Replaces RE-17 4/11)
www.Lochinvar.com
PDP-5M-10/11-Printed in U.S.A.