Lochinvar HCX09 080 User Manual

Immersion Thermostat Model
Engineered and constructed for commercial, industrial, and institutional applications.
Advanced Electronic Control - LCD readout displays operational
and diagnostic information in words, not codes. Standard features include: Low Water Cutoff, Element Sensing and Night Setback.
Glass-Lined Steel Tank–The durable glass lining is fused to the
tank at 1600°F to assure lasting protection against rust and corrosion while providing clean, clear hot water. 300 psi test pressure provides 150 psi working pressure.
Tank Saver Anode – A large diameter, high capacity anode inhibits
corrosion of the tank interior for long, trouble-free service.
Standard Hi-Power Commercial Electric Water Heaters
®
Heating Elements – Plated, incoloy immersion type heating
elements provide long life and resistance to lime scale build-up. The low watt density elements have lower surface temperatures and more surface area.
Standard V oltages – 208, 240 and 480 are wired from the factory for
three phase. The three phase wiring can be field converted to single phase. (277 is configured as single phase only .)
Energy Cut-Off–Shuts off electrical power to the elements should
the water temperature in the tank exceeds 200°F.
Overcurrent Protection Fuses–All elements and controls are fused
in accordance with U.L. requirements when current exceeds 48 amps.
ASME Temperature and Pressure Relief Valve - Factory provided.
Non-CFC Foam Insulation– Superior material formulation provides
uniform tank coverage with a thick blanket of insulating foam. This non-CFC polyurethane closed cell foam minimizes standby losses and maximizes heat retention.
Hinged Access Door–Provides easy access from front
of heater to electrical controls.
3 Year Limited Tank Warranty, 1-Year Limited Parts Warranty
–See warranty for details
Meets ASHRAE Energy Efficiency Standards
Dimensions & Specifications
T
AMPERAGE TABLE
Single Phase Three Phase
KW 208V 240V 277V 480V 208V 240V 480V
6 28.8 25.0 21.7 12.5 16.7 14.4 7.2 9 43.3 37.5 32.5 18.8 25.0 21.7 10.8 12 57.7 50.0 43.3 25.0 33.3 28.9 14.4
13.5 64.9 56.3 48.7 28.1 37.5 32.5 16.2 15 72.1 62.5 54.2 31.3 41.6 36.1 18.0 18 86.5 75.0 65.0 37.5 50.0 43.3 21.7 24 115.4 100.0 86.6 50.0 66.6 57.7 28.9 27 129.8 112.5 97.5 56.3 74.9 65.0 32.5 30 144.2 125.0 108.3 62.5 83.3 72.2 36.1 36 173.1 150.0 130.0 75.0 99.9 86.6 43.3
40.5 194.7 168.8 146.2 84.4 112.4 97.4 48.7
GALLON
45 216.9 187.5 162.5 93.8 124.9 108.3 54.1 54 N/A 225.0 194.9 112.5 149.9 129.9 65.0
IMMERSION THERMOSTAT w/ CONTACTORS
VOLTAGE SCHEDULE
T - 208V / 1 or 3 PH W - 277V / 1 PH P - 240V / 1 or 3 PH X - 480V / 1 or 3 PH
VOLTAGE
1-1/4” WATER OUTLET
CONDUIT OPENING
KILOWATT
CAPACITY
T&P
C
A
For Ease In Ordering
By Model Number
DRAIN VALVE
H C X 45 080
1-1/4” INLE OPENING
5-1/4”
B
This heater is a 480 volt, 3 phase,
IMMERSION
HI-POWER
THERMOSTAT
45 KW, 80 gallon
Standard Hi-Power model
with immersion thermostats.
Model Gallon GPH @ Number of Shipping Number KW Capacity 100°F Rise Elements A B C Weight
HC(X)06 050 6 50 25 3 55-3/4” 21-3/4” 27” 265 HC(X)09 050 9 50 37 3 55-3/4” 21-3/4” 27” 265 HC(X)12 050 12 50 49 3 55-3/4” 21-3/4” 27” 265 HC(X)13 050 13.5 50 55 3 55-3/4” 21-3/4” 27” 265 HC(X)15 050 15 50 61 3 55-3/4” 21-3/4” 27” 265 HC(X)18 050 18 50 74 3 55-3/4” 21-3/4” 27” 265 HC(X)24 050 24 50 98 6 55-3/4” 21-3/4” 27” 265 HC(X)27 050 27 50 111 6 55-3/4” 21-3/4” 27” 265 HC(X)30 050 30 50 123 6 55-3/4” 21-3/4” 27” 265 HC(X)36 050 36 50 148 6 55-3/4” 21-3/4” 27” 265 HC(X)40 050 40.5 50 166 9 55-3/4” 21-3/4” 27” 265 HC(X)45 050 45 50 194 9 55-3/4” 21-3/4” 27” 265 HC(X)54 050 54 50 221 9 55-3/4” 21-3/4” 27” 265 HC(X)06 080 6 80 25 3 60-1/4” 25-1/2” 31” 280 HC(X)09 080 9 80 37 3 60-1/4” 25-1/2” 31” 280 HC(X)12 080 12 80 49 3 60-1/4” 25-1/2” 31” 280 HC(X)13 080 13.5 80 55 3 60-1/4” 25-1/2” 31” 280 HC(X)15 080 15 80 61 3 60-1/4” 25-1/2” 31” 280 HC(X)18 080 18 80 74 3 60-1/4” 25-1/2” 31” 280 HC(X)24 080 24 80 98 6 60-1/4” 25-1/2” 31” 280 HC(X)27 080 27 80 111 6 60-1/4” 25-1/2” 31” 280 HC(X)30 080 30 80 123 6 60-1/4” 25-1/2” 31” 280 HC(X)36 080 36 80 148 6 60-1/4” 25-1/2” 31” 280 HC(X)40 080 40.5 80 166 9 60-1/4” 25-1/2” 31” 280 HC(X)45 080 45 80 194 9 60-1/4” 25-1/2” 31” 280 HC(X)54 080 54 80 221 9 60-1/4” 25-1/2” 31” 280 HC(X)06 119 6 119 25 3 62-1/4” 29-1/2” 35” 390 HC(X)09 119 9 119 37 3 62-1/4” 29-1/2” 35” 390 HC(X)12 119 12 119 49 3 62-1/4” 29-1/2” 35” 390 HC(X)13 119 13.5 119 55 3 62-1/4” 29-1/2” 35” 390 HC(X)15 119 15 119 61 3 62-1/4” 29-1/2” 35” 390 HC(X)18 119 18 119 74 3 62-1/4” 29-1/2” 35” 390 HC(X)24 119 24 119 98 6 62-1/4” 29-1/2” 35” 390 HC(X)27 119 27 119 111 6 62-1/4” 29-1/2” 35” 390 HC(X)30 119 30 119 123 6 62-1/4” 29-1/2” 35” 390 HC(X)36 119 36 119 148 6 62-1/4” 29-1/2” 35” 390 HC(X)40 119 40.5 119 166 9 62-1/4” 29-1/2” 35” 390 HC(X)45 119 45 119 194 9 62-1/4” 29-1/2” 35” 390 HC(X)54 119 54 119 221 9 62-1/4” 29-1/2” 35” 390
HP I-01
Lochinvar, LLC • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
(Reprint HPI-01 10/11)