Immersion Thermostat Model
Engineered and constructed for commercial,
industrial, and institutional applications.
Outstanding Features
• Advanced Electronic Control - LCD readout displays operational
and diagnostic information in words, not codes. Standard features
include: Low Water Cutoff, Element Sensing and Night Setback.
• Glass-Lined Steel Tank–The durable glass lining is fused to the
tank at 1600°F to assure lasting protection against rust and corrosion
while providing clean, clear hot water. 300 psi test pressure provides
150 psi working pressure.
• Tank Saver Anode – A large diameter, high capacity anode inhibits
corrosion of the tank interior for long, trouble-free service.
Standard Hi-Power
Commercial Electric
Water Heaters
®
• Heating Elements – Plated, incoloy immersion type heating
elements provide long life and resistance to lime scale build-up.
The low watt density elements have lower surface temperatures
and more surface area.
• Standard V oltages – 208, 240 and 480 are wired from the factory for
three phase. The three phase wiring can be field converted to single
phase. (277 is configured as single phase only .)
• Energy Cut-Off–Shuts off electrical power to the elements should
the water temperature in the tank exceeds 200°F.
• Overcurrent Protection Fuses–All elements and controls are fused
in accordance with U.L. requirements when current exceeds 48 amps.
• ASME Temperature and Pressure Relief Valve - Factory provided.
• Non-CFC Foam Insulation– Superior material formulation provides
uniform tank coverage with a thick blanket of insulating foam. This
non-CFC polyurethane closed cell foam minimizes standby losses
and maximizes heat retention.
• Hinged Access Door–Provides easy access from front
of heater to electrical controls.
• 3 Year Limited Tank Warranty, 1-Year Limited Parts Warranty
–See warranty for details
Meets ASHRAE Energy Efficiency Standards
Dimensions & Specifications
AMPERAGE TABLE
Single Phase Three Phase
KW 208V 240V 277V 480V 208V 240V 480V
6 28.8 25.0 21.7 12.5 16.7 14.4 7.2
9 43.3 37.5 32.5 18.8 25.0 21.7 10.8
12 57.7 50.0 43.3 25.0 33.3 28.9 14.4
13.5 64.9 56.3 48.7 28.1 37.5 32.5 16.2
15 72.1 62.5 54.2 31.3 41.6 36.1 18.0
18 86.5 75.0 65.0 37.5 50.0 43.3 21.7
24 115.4 100.0 86.6 50.0 66.6 57.7 28.9
27 129.8 112.5 97.5 56.3 74.9 65.0 32.5
30 144.2 125.0 108.3 62.5 83.3 72.2 36.1
36 173.1 150.0 130.0 75.0 99.9 86.6 43.3
40.5 194.7 168.8 146.2 84.4 112.4 97.4 48.7
GALLON
45 216.9 187.5 162.5 93.8 124.9 108.3 54.1
54 N/A 225.0 194.9 112.5 149.9 129.9 65.0
IMMERSION THERMOSTAT w/ CONTACTORS
VOLTAGE SCHEDULE
T - 208V / 1 or 3 PH W - 277V / 1 PH
P - 240V / 1 or 3 PH X - 480V / 1 or 3 PH
VOLTAGE
1-1/4”
WATER
OUTLET
CONDUIT
OPENING
KILOWATT
CAPACITY
T&P
C
A
For Ease In Ordering
By Model Number
DRAIN
VALVE
H C X 45 080
1-1/4” INLE
OPENING
5-1/4”
B
This heater is a 480 volt, 3 phase,
IMMERSION
HI-POWER
THERMOSTAT
45 KW, 80 gallon
Standard Hi-Power model
with immersion thermostats.
Model Gallon GPH @ Number of Shipping
Number KW Capacity 100°F Rise Elements A B C Weight
HC(X)06 050 6 50 25 3 55-3/4” 21-3/4” 27” 265
HC(X)09 050 9 50 37 3 55-3/4” 21-3/4” 27” 265
HC(X)12 050 12 50 49 3 55-3/4” 21-3/4” 27” 265
HC(X)13 050 13.5 50 55 3 55-3/4” 21-3/4” 27” 265
HC(X)15 050 15 50 61 3 55-3/4” 21-3/4” 27” 265
HC(X)18 050 18 50 74 3 55-3/4” 21-3/4” 27” 265
HC(X)24 050 24 50 98 6 55-3/4” 21-3/4” 27” 265
HC(X)27 050 27 50 111 6 55-3/4” 21-3/4” 27” 265
HC(X)30 050 30 50 123 6 55-3/4” 21-3/4” 27” 265
HC(X)36 050 36 50 148 6 55-3/4” 21-3/4” 27” 265
HC(X)40 050 40.5 50 166 9 55-3/4” 21-3/4” 27” 265
HC(X)45 050 45 50 194 9 55-3/4” 21-3/4” 27” 265
HC(X)54 050 54 50 221 9 55-3/4” 21-3/4” 27” 265
HC(X)06 080 6 80 25 3 60-1/4” 25-1/2” 31” 280
HC(X)09 080 9 80 37 3 60-1/4” 25-1/2” 31” 280
HC(X)12 080 12 80 49 3 60-1/4” 25-1/2” 31” 280
HC(X)13 080 13.5 80 55 3 60-1/4” 25-1/2” 31” 280
HC(X)15 080 15 80 61 3 60-1/4” 25-1/2” 31” 280
HC(X)18 080 18 80 74 3 60-1/4” 25-1/2” 31” 280
HC(X)24 080 24 80 98 6 60-1/4” 25-1/2” 31” 280
HC(X)27 080 27 80 111 6 60-1/4” 25-1/2” 31” 280
HC(X)30 080 30 80 123 6 60-1/4” 25-1/2” 31” 280
HC(X)36 080 36 80 148 6 60-1/4” 25-1/2” 31” 280
HC(X)40 080 40.5 80 166 9 60-1/4” 25-1/2” 31” 280
HC(X)45 080 45 80 194 9 60-1/4” 25-1/2” 31” 280
HC(X)54 080 54 80 221 9 60-1/4” 25-1/2” 31” 280
HC(X)06 119 6 119 25 3 62-1/4” 29-1/2” 35” 390
HC(X)09 119 9 119 37 3 62-1/4” 29-1/2” 35” 390
HC(X)12 119 12 119 49 3 62-1/4” 29-1/2” 35” 390
HC(X)13 119 13.5 119 55 3 62-1/4” 29-1/2” 35” 390
HC(X)15 119 15 119 61 3 62-1/4” 29-1/2” 35” 390
HC(X)18 119 18 119 74 3 62-1/4” 29-1/2” 35” 390
HC(X)24 119 24 119 98 6 62-1/4” 29-1/2” 35” 390
HC(X)27 119 27 119 111 6 62-1/4” 29-1/2” 35” 390
HC(X)30 119 30 119 123 6 62-1/4” 29-1/2” 35” 390
HC(X)36 119 36 119 148 6 62-1/4” 29-1/2” 35” 390
HC(X)40 119 40.5 119 166 9 62-1/4” 29-1/2” 35” 390
HC(X)45 119 45 119 194 9 62-1/4” 29-1/2” 35” 390
HC(X)54 119 54 119 221 9 62-1/4” 29-1/2” 35” 390
HP I-01
Lochinvar, LLC • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
(Reprint HPI-01 10/11)
www.Lochinvar.com