Heating your home or business is one of the biggest investments you’ll ever make…and you deserve a heating system that delivers unmatched comfort, dependability and energy savings, year after year. That’s why Efficiency+ from Lochinvar is the smart choice for heating.
Efficiency+, with inputs ranging from 150,000 to 300,000 Btu/hr, more than lives up to its name, with an outstanding 84% AFUE. It has two­stage firing that saves fuel by closely matching heat output to system demand, maximizing operating efficiency.
Two-Stage Firing
During the majority of the heating season less than full boiler input is required to satisfy a heat load. For this reason Lochinvar has developed a two-stage firing system. Two-stage firing — standard equipment on all Efficiency+ boilers —provides dramatic fuel savings by reducing heat output 50%. That means when outdoor temperatures become warmer, the boiler will use less fuel to maintain comfortable indoor temperatures.
High Fire
With standard two-stage firing, Efficiency+ reduces gas consumption.
Low Fire
On colder days the boiler fires at full input.
In warmer conditions Efficiency+ reduces heat output to save energy
Stage 1
Stage 2
and reduce cycling.
Trouble-Free Operation
There’s nothing more irritating than a boiler that sputters out when you need it most. That’s why Efficiency+ has an integrated boiler control that ensures safe burner operation and prevents nuisance flame-failures.
Efficiency+ is also designed to operate on low gas pressure — a key consideration in regions where natural gas supply pressure is in the 4 - 5 inch range.
Space-Saving Design
With Efficiency+, you get high efficiency heating in a surprisingly compact unit. It fits easily where other boilers won’t.
The Efficiency+ is remarkably light because of its copper tube heat exchanger and other design breakthroughs. For example, Efficiency+ uses Loch-Heat™ tile to reduce unit weight by 25% as compared to conventional cast refractory materials. Loch-Heat tile also increases efficiency by reflecting heat back into the combustion chamber rather than absorbing it.
High Efficiency, Gas Fired Heating Boiler
Thermal Efficiency—Your Reliable Yardstick For Savings
Thermal Efficiency
Efficiency+ has an 84% thermal efficiency rating, which means 84 cents out of every fuel dollar are used to create heat. Other efficiency ratings can be misleading and result in artificially high ratings.
Combustion Efficiency
Efficiency+
®
Boiler Dimensions & Specifications
Efficiency+ Boiler Dimensions & Spec i fi ca tions
Input Heating Net Model Max AFUE Capacity I=B=R Gas Vent Shipping Number MBH % MBH MBH B D E G Conn. Size Weight
EBN150 150 83.2 129 112 19-3/4” 16” 7-1/4” 11-3/4” 3/4” 5” 245 EBN200 200 83.1 170 148 23-3/4” 20” 9-1/4” 11-3/4” 3/4” 5” 265 EBN250 250 83.2 218 190 27-1/2” 23-3/4” 11” 11-3/4” 3/4” 6” 290 EBN300 300 84.0 252 219 31-1/4” 27-1/2” 13” 11-3/4” 3/4” 6” 310
Notes: Change ‘N’ to ‘L’ to denote L.P. gas models Electrical Requirements: 120 VAC / 2 AMP Water connections are 1-1/2” NPT Net ratings based on piping and pick-up allowance of 1.15 Performance data based on manufacturer test results.
Standard Features
84% AFUE
Two Stage Firing
Sealed Combustion Chamber
Stainless Steel Burners
Low NOx Operation Exceeds the most
Stringent Air Quality Requirements
ASME Copper Finned Tube Heat Exchanger
160 PSI Working Pressure
Gasketless Heat Exchanger Design
Automatic Reset High Limit
Loch-Heat Ceramic Tile Combustion Chamber
Hot Surface Ignition
ASME Pressure Relief Valve
24 Volt Control System
Pump Relay
Venting Options
Conventional Vents into conventional flue or vent breaching using Type B double wall vent.
** Outdoor Vent Kit
Use when indoor space is a problem or if outdoor location gives better access.
10 Year Limited Warranty
on Heat Exchanger (See warranty for details)
Optional Equipment
Adjustable High Limit
w/ Manual Reset
Alarm Bell
Cupro-Nickel Heat Exchanger
Flow Switch
Indoor/Outdoor Reset
Manual Reset Low Water Cut-Off
w/test
MP2 Sequencer
Stack Frame
Pump Delay w/ Freeze Protection
** E+ DirectAire Vent with
Sidewall Inlet
Draws fresh combustion air from an outside wall horizontally, and vents combustion by-products through a vertical flue.
Direct Vent Vertical Draws fresh combustion air from outside, and vents combustion by-products through a vertical flue.
Available Firing Systems
M9 Hot Surface Ignition with Electronic Supervision (Standard) M7 California Code
For Ease In Ordering
By Model Number
E B N 150
natural gas Efficiency+ boiler.
Registered Under U.S. Patent #5,989,020
Boiler
Efficiency+
This is a 150,000 Btu/hr
** Direct Vent Horizontal
Draws fresh combustion air from outside, then vents by-products through a side wall.
** Requires factory supplied vent kit.
Natural Gas
Input
Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
EBN-04 Revised EBN-04 9/08)
www.Lochinvar.com
FG-5M-3/10-Printed In U.S.A.
Loading...