This manual must only be used by
a qualified heating installer / service
technician. Read all instructions,
including this manual along with
the Crest Installation and Operation
Manual, and the Crest Service Manual,
before installing. Perform steps in the
order given. Failure to comply could
result in severe personal injury, death,
or substantial property damage.
Revision Notes .................................................. Back Cover
Hazard definitions
The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or
to important information concerning the life of the product.
DANGER
WARNING
CAUTION
CAUTION
NOTICE
2
DANGER indicates an imminently hazardous situation which, if not avoided, will result in death or serious
injury.
WARNING indicates a potentially hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate
injury.
CAUTION used without the safety alert symbol indicates a potentially hazardous situation which, if not
avoided, may result in property damage.
NOTICE indicates special instructions on installation, operation, or maintenance that are important but not
related to personal injury or property damage.
Page 3
Please read before proceeding
Dual Fuel Supplemental Manual
WARNING
NOTICE
Installer – Read all instructions, including
this manual, the Crest Installation and
Operation Manual and the Crest Service
Manual, before installing. Perform steps
in the order given.
User – This manual is for use only
by a qualified heating installer/
service technician. Refer to the User’s
Information Manual for your reference.
Have this boiler serviced/inspected by
a qualified service technician, at least
annually.
Failure to comply with the above could
result in severe personal injury, death or
substantial property damage.
When calling or writing about the boiler
– Please have the boiler model and serial
number from the boiler rating plate.
Consider piping and installation when
determining boiler location.
Any claims for damage or shortage in
shipment must be filed immediately
against the transportation company by
the consignee.
When servicing boiler –
• To avoid electric shock, disconnect electrical supply
before performing maintenance.
• To avoid severe burns, allow boiler to cool before
performing maintenance.
Boiler operation –
• Do not block flow of combustion or ventilation air to
the boiler.
• Should overheating occur or gas supply fail to shut off,
do not turn off or disconnect electrical supply to
circulator. Instead, shut off the gas supply at a location
external to the appliance.
• Do not use this boiler if any part has been under water.
The possible damage to a flooded appliance can be
extensive and present numerous safety hazards. Any
appliance that has been under water must be replaced.
WARNING
WARNING
Factory warranty (shipped with unit) does
not apply to units improperly installed or
improperly operated.
Failure to adhere to the guidelines on this
page can result in severe personal injury,
death, or substantial property damage.
If the information in this manual is not
followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
This appliance MUST NOT be installed in
any location where gasoline or flammable
vapors are likely to be present.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do
not use any phone in your building.
• Immediately call your gas supplier
from a near by phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier,
call the fire department.
• Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier.
3
Page 4
The Crest Dual Fuel - How it works...
Dual Fuel Supplemental Manual
1. Propane gas connection
The propane gas connection pipe is a threaded black iron pipe
connection. This pipe should be connected to the incoming gas
supply to deliver propane gas to the boiler.
2. Natural gas connection
The natural gas connection pipe is a threaded black iron pipe
connection. This pipe should be connected to the incoming gas
supply to deliver natural gas to the boiler.
3. Fuel selection switch
Switches the unit between natural and propane gas.
4. Natural gas indicator light (green)
Indicates that natural gas operation has been selected.
5. Propane gas indicator light (red)
Indicates that propane gas operation has been selected.
6.Small natural gas valve (Valve 1 Natural)
The small natural gas valve senses the negative pressure
created by the blowers, allowing gas to flow only if the gas
valves are powered and combustion air is flowing.
7. Small propane valve (Valve 1 Propane)
The small propane gas valve senses the negative pressure
created by the blowers, allowing gas to flow only if the gas
valves are powered and combustion air is flowing.
Models FBD751 - 2001
8. Large natural gas valve (Valve 2 Natural)
The large natural gas valve senses the negative pressure created
by the blowers, allowing gas to flow only if the gas valves are
powered and combustion air is flowing.
9. Large propane gas valve (Valve 2 Propane)
The large propane gas valve senses the negative pressure created
by the blowers, allowing gas to flow only if the gas valves are
powered and combustion air is flowing.
10. Natural shutoff valve
The natural shutoff valve is used to isolate the boiler gas
train from the gas supply.
11. Propane shutoff valve
The propane shutoff valve is used to isolate the boiler gas
train from the gas supply.
2
1
DIR #2000508194
3
7
9
DIR #2000508187
5
4
2
1
10
6
11
8
Front View
4
DIR #2000508206
Left Side (inside unit)
Page 5
Ratings
Dual Fuel Supplemental Manual
Crest
AHRI Rating
Model Number
Note: Change “N” to
“L” for L.P. gas models.
Min Max
FB(N,L,D)075150750720626
FB(N,L,D)1001501000960835
FB(N,L,D)125162125012001043
FB(N,L,D)150160150014401252
FB(N,L,D)175170175016801460
FB(N,L,D)200180200019201670
NOTICE
Maximum allowed working pressure is located on the rating plate.
Input
MBH
(Notes 4 - 8)
Notes:
1. The ratings are based on standard test procedures
prescribed by the United States Department of Energy.
2. Net AHRI ratings are based on net installed radiation of
sufficient quantity for the requirements of the building
and nothing need be added for normal piping and
pickup. Ratings are based on a piping and pickup
allowance of 1.15.
3. Crest boilers require special gas venting. Use only
the vent materials and methods specified in the Crest
Installation and Operation Manual.
4. Standard Crest boilers are equipped to operate from sea
level to 4,500 feet only. The boiler will de-rate by 1.4%
for each 1,000 feet above sea level up to 4,500 feet.
5. High altitude Crest Models are equipped to operate from
3,000 to 12,000 feet only. e boiler will not de-rate up
to 5,500 feet and will de-rate by 1.6% for each 1,000 feet
above 5,500 feet. e operation given in this manual
remains the same as the standard boilers. A high altitude
label (as shown in FIG A.) is also a xed to the unit.
Notice: Capacities shown are for Natural G as. Please consult supplier for proper gas pipe sizing for propane.
Table 1A First Stage Piping at High Pressure_10 PSI
Table 1B Second Stage Piping at Low Pressure_1/2 PSI
Dual Fuel Supplemental Manual
Check inlet gas supply
WARNING
NOTICE
The gas piping must be sized for the proper flow and length of
pipe, to avoid excessive pressure drop. Both the gas meter and
the gas regulator must be properly sized for the total gas load.
If you experience a pressure drop greater than 1 inch w.c.
(249 Pa), the meter, regulator, or gas line is undersized or in
need of service. Perform the steps below when checking inlet
gas supply:
1. Turn the main power switch to the “OFF” position.
2. Shut off gas supply at the manual gas valve in the gas
piping to the appliance.
3. Remove the 1/8" pipe plug on the flange to the factory
supplied gas shutoff valve and install a suitable 1/8"
fitting (field supplied) for the manometer tubing. Place the
tubing of the manometer over the tap once the 1/8"
fitting is installed as shown in FIG.’s 1-1 and 1-2.
6
DO NOT adjust or attempt to measure gas
valve outlet pressure. Attempting to alter
or measure the gas valve outlet pressure
could result in damage to the valve, causing
potential severe personal injury, death, or
substantial property damage.
The Dual Fuel Crest is equipped with
two (2) inlet gas connections. Each
connection must be checked to ensure
proper operation.
4. Slowly turn on the gas supply at the factory installed
manual gas valve.
5. Turn the power switch to the “ON” position.
6. Adjust the temperature set point on the control panel of
the SMART TOUCH control module to call for heat or
utilize Service Mode, see page 10 of this manual.
7. Observe the gas supply pressure as the burner fires at
100% of rated input. Percent of burner input will be
displayed on the Modulation Screen.
8. Ensure inlet pressure is within specified range.
Minimum and maximum gas supply pressures are
specified in this section of the manual.
9. If gas supply pressure is within normal range and no
adjustments are needed, proceed on to Step 11.
10. If the gas pressure is out of range, contact the gas utility,
gas supplier, qualified installer or service agency to
determine the necessary steps to provide proper gas
pressure to the control.
11. Turn the power switch to the “OFF” position.
12. Shut off the gas supply at the manual gas valve in the gas
piping to the appliance.
13. Remove the manometer from the pressure tap on top of
the gas valve. Remove the 1/8" (3 mm) field supplied
fitting and reinstall the pipe plug removed in Step 3.
Page 7
1 Gas connections (continued)
Dual Fuel Supplemental Manual
WARNING
14. Turn on the gas supply at the manual gas valve.
15. Turn the power switch to the “ON” position.
16. Adjust the temperature set point on the control panel of
the SMART TOUCH control module to the desired
water temperature so the appliance will call for heat.
17. Check burner performance by cycling the system while
you observe burner response. The burner should ignite
promptly. Flame pattern should be stable. Turn system
off and allow burner to cool, then cycle burner again to
ensure proper ignition and flame characteristics.
18. Repeat Steps 1 - 17 for both natural and LP gas supply.
Do not check for gas leaks with an open
flame -- use the bubble test. Failure to
use the bubble test or check for gas leaks
can cause severe personal injury, death, or
substantial property damage.
Gas Pressure
The gas pressure must remain between 4 inches w.c. (.99 kPa)
minimum and 14 inches w.c. (3.5 kPa) maximum for Natural
gas and between 4 inches w.c. (.99 kPa) minimum and 14
inches w.c. (3.5 kPa) maximum for LP gas during standby
(static) mode and while in operating (dynamic) mode. If an
in-line regulator is used, it must be a minimum of 10 feet (3 m)
from the Crest boiler. It is very important that the gas line is
properly purged by the gas supplier or utility company. Failure
to properly purge the lines or improper line sizing, will result
in ignition failure.
Ignition problems are especially noticeable in NEW LP
installations and also in empty tank situations. This can
also occur when a utility company shuts off service to an
area to provide maintenance to their lines.
Gas valve replacement
The gas valve MUST NOT be replaced with a
conventional gas valve under any circumstances. As
an additional safety feature, the gas valves have flanged
connections to the venturis and blowers.
WARNING
WARNING
Failure to follow all precautions
could result in fire, explosion, or
death!
DO NOT adjust or attempt to
measure gas valve outlet pressure.
Attempting to alter or measure
the gas valve outlet pressure could
result in damage to the valve,
causing potential severe personal
injury, death, or substantial property
damage.
Figure 1-1 Inlet Gas Supply Check_Natural
DIR #2000508192
Figure 1-2 Inlet Gas Supply Check_Propane
DIR #2000508193
7
Page 8
2 Start-up
Dual Fuel Supplemental Manual
Final checks before starting the boiler
Read the Crest Service Manual to familiarize yourself
with SMART TOUCH control module operation. Read
this manual, page 9 for proper steps to start boiler.
Verify the boiler and system are full of water and all
system components are correctly set for operation.
Verify the preparation procedures of Section 9 of the
Crest Installation and Operation Manual have been
completed.
Verify electrical connections are correct and securely
attached.
Inspect vent piping and air piping for signs of deterioration
from corrosion, physical damage or sagging. Verify air
piping and vent piping are intact and correctly installed
per this manual.
Start the boiler
1. Read and follow the Operating instructions in FIG. 2-1,
page 9.
Check vent piping and air piping
1. Check for gastight seal at every connection, seam of air
piping, and vent piping.
WARNING
Check gas piping
1. Check around the boiler for gas odor following the
procedure in the Crest Installation and Operation
Manual (connecting gas supply piping).
WARNING
Venting system must be sealed gastight
to prevent flue gas spillage and carbon
monoxide emissions, which will result in
severe personal injury or death.
If you discover evidence of any gas leak,
shut down the boiler at once. Find the
leak source with a bubble test and repair
immediately. Do not start the boiler again
until corrected. Failure to comply could
result in severe personal injury, death, or
substantial property damage.
If boiler does not start correctly
1. Check for loose connections, blown fuse or service switch
off?
2. Is external limit control (if used) open? Is boiler water
temperature above 200°F (93°C)?
3. Is the boiler receiving a call for heat?
4. Is gas turned on at meter and boiler?
5. Is incoming gas pressure less than 4 inches w.c. (.99 kPa)?
If none of the above corrects the problem, refer to the
Troubleshooting Section of the Crest Service Manual.
Check system and boiler
Check water piping
1. Check system piping for leaks. If found, shut down the
boiler and repair immediately. (See WARNINGS in
the Crest Installation and Operation Manual (startup)
regarding failure to repair leaks.)
2. Vent any remaining air from the system using manual
vents. Air in the system will interfere with circulation
and cause heat distribution problems and noise.
8
Page 9
2 Start-up (continued)
Figure 2-1 Operating Instructions
FOR YOUR SAFETY READ BEFORE OPERATING
WARNING: If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury, or loss of life.
Dual Fuel Supplemental Manual
A. T his appliance does not have a pilot. It is
equipped with an ignition device which
automatically lights the burner. Do not try
to light the burner by hand.
B. BE FOR E OP ER ATI NG sme ll a ll ar ou nd
the a pp lia nce area fo r gas. B e s u re to
smell next to the floor because some gas
is heavie r than air and will settle on the
floor.
WHAT T O DO IF YOU SMELL GAS
• D o not tr y to light an y ap pl ian ce.
• Do not touch any electric switch; do
not use an y phon e i n your b ui ldi ng .
OPERATIN G INSTRUCTIONS
1. STOP! Read the safety information
above on this label.
2. Set the thermostat to lowest setting.
3. Turn off all electric power to the
app lia nc e.
4. T his appliance is equipped with an
ign ition device which automatically lights
the burner. Do not try to light the burner
by hand .
5. Remove front door.
6. Turn gas shutoff valve counterclockwise
to “ O FF”. H an dle wil l be pe rpen dicula r to
pipe. Do not force.
7. Wait five (5) minutes to clear out any gas.
If you then smell gas, ST O P ! Follow “B”
in the safety in forma tion above this label.
If you don’t smell gas, go to next step.
• Immediately call your gas supplier from a
neig hbor ’s phon e. Fol low t h e gas su pp lier’s
instr uctions.
• If yo u can n ot re ach your ga s sup pl ier , call
the fire department.
C. Use only your hand to turn the gas control knob.
Never use tools. If the handle will not turn by
hand , do n’t try to re pair i t, call a qua lified se rvice
technician. Force or attempted repair may
result in a fire or explosion.
D. Do n ot us e t his app lia nce if any part ha s be en
unde r wa t er. I mm ed iate ly c all a qu al ified
ser vice tech nician to in spe ct th e a pplianc e an d
to replace any part of the control system and
any gas co n trol w hich ha s be en un de r wa t er.
8. Tur n g as sh ut of f val ve clo ck wise to “ O N”.
Handle will be paralle l to pi pe.
9. Inst al l fr on t d oor.
10. Turn on all electric power to appliance.
11. Set t h er mostat to desired se tting .
12. If the ap pl iance w ill not oper ate, fol low th e
instr uctio ns “T o Tu rn Off G a s To App lia nc e ” and
call your service technician or gas supplier.
TO TURN OFF GAS TO APPLIANCE
1. Set the thermostat to lowest setting.
2. T urn off all e le ctr ic po we r to the ap pl ian ce
if servic e is t o be perf or me d.
3. Remove front door.
4. Turn gas shut off valve counterclockwise to
“OFF”. Handle will be perpendicular to pipe.
Do not force.
5. Inst al l fr on t d oor.
L BL2 0053 RE V B
9
Page 10
2 Start-up
Dual Fuel Supplemental Manual
Check flame and combustion
1. Turn the main power off to the boiler by placing the
“On/Off” switch in the OFF position.
2. Remove the fitting from the flue collector. Note:
Combustion measurements will be made at this point.
3. Turn the main power on to the boiler by placing the
“On/Off” switch in the ON position.
4. Navigate to the Service Maintenance Screen from the
Home Screen by pressing the SETUP button, enter the
installer password, and then using the scrolling menu
feature on the left side, scroll down to the SERVICE
MAINTENANCE button.
5. On the Service Maintenance Screen place heater into
Service Mode by selecting the START button, then
selecting Set Gas Valve 1 - High.
6. Insert the probe from a combustion analyzer into the
hole left by the removal of the fitting.
7. Once the boiler has modulated up to rate, measure the
combustion. The values should be in the range listed
in Table 2A below. CO levels should be less than 200
ppm for a properly installed unit. If the combustion is
not within range reference the Troubleshooting Section
in the Crest Service Manual for possible causes and
corrective actions.
8. Once the heater analysis is complete, test the safety shutoff
device by turning the manual shutoff valve to the OFF
position and ensuring the heater shuts down and registers an
alarm. Open the manual shutoff valve and reset the control.
9. Turn the main power off to the boiler and replace the
fitting into the flue pipe connection.
10. Place the boiler back into normal operation.
WARNING
You must replace the fitting to prevent flue
gas spillage into the room. Failure to comply
could result in severe personal injury, death,
or substantial property damage.
Dual fuel switching instructions
1. Turn the main power off to the boiler by placing the “On/
Off” switch in the OFF position (FIG. 2-2).
2. Using the fuel selector switch (FIG. 2-2), select the desired
fuel.
Figure 2-2 Fuel Selector Switch
Table 2A Flue Products Chart
Flue Products
Gas Valve
Valve 1 High9.24.6
Valve 1 Low9.04.9
Valve 2 High9.3 4.4
Valve 2 Low8.75.5
Natural Gas
CO2 (%)O2 (%)
Propane
Valve 1 High11.04.1
Valve 1 Low10.05.6
Valve 2 High11.14.0
Valve 2 Low10.74.6
**All set points should be within +/- 0.2%**
MAIN POWER
SWITCH
NATURAL PERSONALITY I.D.
PROPANE PERSONALITY I.D.
FUEL SELECTION
SWITCH
NATURAL
DIR #2000508194
PROPANE
IMG00063
DETAIL
10
Page 11
2 Start-up (continued)
Dual Fuel Supplemental Manual
3. Turn off all shutoff valves for the fuel not in use (FIG. 2-3).
Figure 2-3 Shutoff Valves
NATURAL
SHUTOFF
VALV E
PROPANE
SHUTOFF
VALV E
DIR #2000508189
Figure 2-4 Personality Plug
4. Turn on the shutoff valve for the one in use.
5. Turn the main power ON.
6. Using the Touch Screen, accept the appropriate
personality identification as shown in FIG. 2-4.
11
Page 12
3 Diagrams
PRE-MIX SENSOR 1 (S13)
PRE-MIX SENSOR 1 (S11)
FLUE SENSOR (S10)
OUTLET SENSOR (S1)
-T
-T
-T
-T
-T
-T
FLUE SENSOR
OUTLET SENSOR (S9)
1.5A EACH MAX
WARNING
OPTIONAL USB/WIFI
J3-3
JUNCTION BOX
TERMINAL STRIP
120V SUPPLY "L"
TERMINAL STRIP
120V SUPPLY "N"
120VACNEUTRAL
INTEGRATED CONTROL
ON/OFF
SWITCH
F2
3.15 A
F4
5.0 A
SYSTEM PUMP
RELAY
BOILER PUMP
RELAY
DHW PUMP
RELAY
X1-1
X1-2
X1-4
X1-8
SMALL GAS
VALVE RELAY
LARGE GAS
VALVE RELAY
X1-6
2-01X1-01X
X10-3
SMALL GAS
VALVE RELAY
LARGE GAS
VALVE RELAY
X10-6
X10-5
X10-4
TERMINAL STRIP
SYSTEM PUMP
CONTACTOR
BOLIER PUMP
CONTACTOR
DHW PUMP
CONTACTOR
BLOWER
RELAY
BLOWER
X6-10
X13-4
X6-1
X2-5
21
3
BAS
X1-1
X1-2
X1-3
FLUE DAMPER
TRANSFORMER
12
3
24V
TRANSFORMER
FLUE DAMPER
X6-3
X1-12
!
RIBBON CABLE
BOARD
TEST
SWITCH
LWCO
PROBE
LWCO RESET
J2-2
J3-5
X6-5
X6-15
X6-12
X13-1
X6-6
X3-3
X3-4
X3-1
X3-2
X6-11
X6-2
X1-3
LWCO
CONTROL
BLOCKED FLUE
SWITCH
BLOCKED DRAIN
SWITCH
ALARM
CONTACTS
RUN-TIME
CONTACTS
TANK
THERMOSTAT
LOUVER
PROVING
AUX
SWITCH 1
AUX
SWITCH 2
ENABLE
W
CN1-12
J3-6
CN1-10
CN1-11
CN1-9
X6-4
CN1-8
CN1-7
CN1-1
CN1-3
X1-3
X1-7
X1-10
X2-3
FLAME
SENSE 2
FLAME
SENSE 1
SPARK
GENERATOR
SPARK
ROD
SHIELD
SHIELD
A
B
MODBUS
OPTION
+
-
-
+
RATE
OUT
BOILER
PUMP OUT
SYSTEM RETURN
SENSOR
SYSTEM SUPPLY
SENSOR
0-10V
0-10V
TANK
SENSOR
OUTDOOR
SENSOR
+
+
-
-
0-10V
0-10V
BMS
IN
SYSTEM
PUMP IN
SHIELD
SHIELD
A
B
CASCADE
LARGE
CONNECTION BOARD
CN6-1
CN3-6
CN3-7
CN3-14
CN3-13
CN3-11
CN3-9
CN3-8
CN3-1
CN3-2
CN3-3
CN3-4
CN6-2
CN6-3
CN3-10
X6-14
INTEGRATED
BOARD
X4-1
X4-2
X4-3
X6-3
X6-1
X6-2
X8-20
X8-10
X7-8
X8-13
X8-14
X8-12
INTEGRATED
CONTROL
CN3-4X8-15
X7-7
X8-11
X8-6
X8-16
X8-7
X8-17
X8-1
X8-3
X8-8
X8-2
X8-4
X8-9
X7-1
X7-5
GROUND
X11
LCD
DISPLAY
X4
X5-1
X5-7
X5-2
X5-8
X5-3
X5-9
X5-4
X5-10
X5-5
X5-41
X5-6
CN3-12
BAS
X5-12
J3-2
BOX DEPICTS
SINGLE HOUSING
HIGH VOLTAGE
LOW VOLTAGE
BOX DEPICTS
OPTIONAL ITEMS
X6-8
INLET SENSOR
-T
X6-94
BLOWER
120 VAC
locations when using diagrams to troubleshoot unit.
USB
INTERFACE
"X5"
BLOCK WIRING
IS MODEL
DEPENDENT
X8-1
X8-5
100266316 REV A
24 VAC LOUVER
RELAY COIL
X6-13
CN1-2
R
BLOWER
RELAY
CN1-5
CN1-4
HIGH LIMIT
SWITCH
SMALL
CONNECTION BOARD
CN-1
CN1-6
CN-2
CN-3
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CAM
SWITCH
PROPANE LGPS
NATURAL LGPS
AIR VALVE
PRESS. SWITCH
CAM
SWITCH
PROPANE LIGHT
NATURAL LIGHT
CAM
SWITCH
PROPANE
NATURAL
PROPANE
NATURAL
M
J23
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector blo ck
E
J3-4
DUAL SENSOR
ETHERNET CABLE
USB CABLE
8
43
J17
J8
EXTENSION CABLE
OPTIONAL
GND
J12
J7
J6
J11
J10
J2
24V
BAS
J9
CN-4
DONGLE
AIR VALVE
M
CN6-1
CN6-3
CN6-2
LG CON BRD
X6-181
2
5
X6-17
Notes
1. All wiring must be installed in accordance with: local, st ate, provincial and national code requirements per either N.E.C. in USA or
C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance mu st be replaced, it must be replaced with wire having same wire gauge
(AWG) and rated for a minimum of 105°C. Exceptions: Replacement high voltage spark lead and ribbon cables must be purchas ed
from the factory. Use of a non-approved spark lead or ribbon cables can lead to operational problems which could result in
non-repairable damage to the integrated controller or other components.
WIFI
J2-1
DISCONNECT POWER
BEFORE SERVICING
Figure 3-1 Ladder Diagram
Dual Fuel Supplemental Manual
12
Page 13
3 Diagrams (continued)
Figure 3-2 Wiring Diagram
A
B
+
-
+
-
+
-
+
-
A
B
J10
J2 J11
0-10V
0-10V
0-10V
0-10V
GND
J6
E
DISPLAY
J12
R
W
LARGE CONNECTION BOARD
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
LCD
8
43
USB CABLE
J7
J8
J9
J17
OPTIONAL USB/WIFI
EXTENSION CABLE
J23
OPTIONAL
ETHERNET CABLE
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
LWCO
PROBE
OR/BK
CAM
SWITCH
CAM
SWITCH
CN6-3
CN6-2
CN6-1
CN3-4
CN3-6
CN3-7
CN3-14
CN3-13
CN3-12
CN3-11
CN3-10
CN3-9
CN3-8
CN3-1
CN3-2
CN3-3
CN3-5
DONGLE
CN1-4
CN1-5
CN1-6
CN1-12
CN1-10
CN1-11
CN1-9
CN1-8
CN1-7
CN1-1
CN1-2
CN1-3
TEST
SWITCH
LWCO RESET
BLOCKED FLUE
SWITCH
BLOCKED DRAIN
SWITCH
MODBUS
OPTION
BOILER
PUMP OUT
SYSTEM RETURN
SENSOR
SYSTEM SUPPLY
SENSOR
SENSOR
OUTDOOR
SENSOR
SYSTEM
PUMP IN
CASCADE
LG CON BRD
CN6-2
R
PR
CN6-1
CN6-3
GY
CONTACTS
RUN-TIME
CONTACTS
THERMOSTAT
LOUVER
PROVING
24 VAC LOUVER
RELAY COIL
SWITCH 1
SWITCH 2
SHIELD
SHIELD
RATE
OUT
TANK
BMS
IN
SHIELD
SHIELD
BAS
24V
ALARM
TANK
ENABLE
AUX
AUX
WIFI
SMALL
CONNECTION
BOARD
Y
OR/BK
OR
OR
PROPANE LGPS
NATURAL LGPS
PROPANE LIGHT
NATURAL LIGHT
BAS
BOARD
X1-1
X1-2
X1-3
X6-3GY
X6-1
R
X6-2
PR
X4-1
BK
X4-2
X4-3
BL
BL
BR
W
OR
OR/W
W
BL
BK
Y/BK
-T
INLET SENSOR
-T
OUTLET SENSOR (S9)
-T
OUTLET SENSOR (S1)
-T
FLUE SENSOR
-T
FLUE SENSOR (S10)
-T
PRE-MIX SENSOR 1 (S11)
-T
PRE-MIX SENSOR 1 (S13)
R
R
OR
OR
BL
BK
BR
R
BL
HIGH LIMIT
SWITCH
BL
R
R
OR
LWCO
BOARD
J3-6
J3-5
OR
J3-4
J3-3
J3-2
J2-1
J2-2
BR
BK
"X5"
BLOCK WIRING
IS MODEL
DEPENDENT
Dual Fuel Supplemental Manual
BOX DEPICTS
OPTIONAL ITEMS
BOX DEPICTS
DUAL SENSOR
SINGLE HOUSING
INTEGRATED CONTROL
X8-20
T
X8-10
X7-8
X7-7
R
X8-13
R
X8-14
X8-12
X8-11
X8-5
X8-15
P
X8-6
X8-16
X8-7
X8-17
X8-18
X8-1
X8-3
BL
X8-8
R/W
R
X8-2
X8-4
CAM
SWITCH
W
GY
X8-9
GY
X7-1
BR
X7-5
X7-2
X7-6
X4
X3-3
X3-4
X3-1
X3-2
X6-1
X6-11
X6-2
X6-14
Y
X6-10
X6-4
X6-3
X6-5
X13-1PR
X6-6
X5-1
X5-7
X5-2
X5-8
X5-3
X5-9
X5-4
X5-10
X5-5
X5-41
X5-6
X5-12
X1-6
X1-3
X1-12
X10-1
X10-4
X1-1
X1-2
X1-4
X10-2
X10-5
X10-3
X10-6
X6-18
X6-8
X1-8
X6-9
X6-17
X2-3
X1-7
X1-10
X1-5
X2-5
X13-4
X6-13
X6-15
X6-12
X11
USB
INTERFAC E
PR
T
OR
OR
BL
R
BL
R
BK
GY
BLOWER
W
T
R
R
SPARK
GENERATOR
R
P
FLUE DAMPER
TRANSFORMER
BK
OR/W
OR
OR/BK
ON/OFF
SWITCH
BK
W
G
DISCONNECT POWER
BEFORE SERVICING
LOW VOLTAGE
120 VAC
HIGH VOLTAGE
120V
SUPPLY
GND
LN
BK
OR/W
CAM
SWITCH
CAM
SWITCH
BL
Y
OR
TRANSFORMER
Y
BL
AIR VALVE
PRESSURE
SWITCH
!
WARNING
OR/BK
SMALL
NATURAL
VALVE
R/BK
R/W
LARGE
NATURAL
VALVE
BK
1
BLOWER
TRANSITION
FLAME SENSE
SPARK ROD
MAIN
FLAME SENSE
FLUE DAMPER
1
2
3
24V
Y
BL
OR/R
1.5A EACH MAX
SYSTEM PUMP
CONTACTOR
BOILER PUMP
CONTACTOR
DHW PUMP
CONTACTOR
JUNCTION
BOX
SMALL
PROPANE
VALVE
LARGE
PROPANE
VALVE
32
54321
M
AIR VALVE
M
GND
Notes:
1. All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.
2. If any original equipment wire as supplied with the appliance mu st be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a
minimum of 105°C. Exceptions: Replacement high voltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead
or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or o ther components.
3. Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using
diagrams to troubleshoot unit.
100266353 REV A
13
Page 14
Notes
Dual Fuel Supplemental Manual
14
Page 15
Notes
Dual Fuel Supplemental Manual
15
Page 16
Revision Notes: Revision A (Change #500001029) initial
release.
MM #100268179_DIR #2000509263 Rev A
10/15