Lochinvar CPN0991 User Manual

Page 1
High Efficiency In A Space-Saving Design
Gas Heaters For Commercial Pool Applications
From 500,000 to 2,070,000 Btu/hr
Up to 89% Thermal Efficiency
Less Than 20 ppm NOx Rating
Page 2
Thermal efficiency is higher...while footprint and vent sizes are smaller
®
Lochinvar’s Copper-Fin
2
line of high efficiency commercial gas heaters gives you all the advantages of copper-finned tube heat exchanger technology plus the benefits of a sealed combustion system. Every Copper-Fin model offers four major advantages: higher efficiency, smaller footprint, smaller vent diameters and a wide variety of venting options.
Outstanding thermal efficiency
Copper-Fin2 gas heaters offer a remarkably high 89% thermal efficiency. This means that 89¢ out of every fuel dollar goes into heating the water, dramatically reducing the operating cost of the equipment. Copper-Fin this efficiency through the combination of an advanced fan assisted combustion system and an exclusive gasketless copper-finned tube heat exchanger. A time tested and proven combination.
The heat energy from the combustion process is efficiently transferred into the water as it passes through the solid copper-finned tube heat exchanger. The sealed combustion design of the Copper-Fin external heat loss. This means that the energy dollars heat the water, not the mechanical room. It also ensures that the jacket stays cooler, providing greater safety and requiring less clearance from combustible walls - just 1” in most cases.
2
achieves
2
reduces
Commercial Gas Heaters
Meets the toughest air quality standards
combustion process, the Copper-Fin2 exceeds today’s toughest NOx emissions requirements. An independent certification laboratory test gave us a rating of less than
20 ppm —corrected to 3% O2. And less NOx
2
means a cleaner environment.
Compact design - for installation ease
The Copper-Fin2 is compact enough to fit through standard 36” doorways with ease. Even our 2 million Btu/hr model is only 33-1/2” wide. This
space-
saving design frees up more space in the mechanical room.
And our optional Lochinvar Stack Frame lets you put two units in the footprint of just one. See our Stack Frame literature for more details.
(Indoor use only)
Automatic pumped bypass standard
All Copper-Fin2 heaters are equipped with an automatic high temperature CPVC bypass to ensure proper flow and return water temperatures to the heater. This results in longer equipment life and trouble free operation. The CPVC bypass is provided as standard equipment in a horizontal
configuration. A vertical configuration is also available offering the flexibility to meet mechanical room space requirements or piping constraints.
Making installation easier...for less
High-efficiency, fan-assisted combustion means you can use a smaller diameter vent stack — up to 8” smaller than typically required. This makes installation less expensive and more flexible.
Vent Cost Savings
Btu/hr CONVENTIONAL COPPER-FIN2 INPUT VENT SIZE VENT SIZE $ S
500,000 10” 6” $ 657 650,000 12” 8” $ 731 750,000 14” 8” $ 1,450 990,000 16” 10” $ 1,790 1,260,000 16” 12” $ 1,463 1,440,000 18” 12” $ 2,432 1,800,000 20” 14” $ 3,526 2,070,000 22” 14” $ 3,738
*Comparison based on 25´ vent system using Type “B” double wall vent material,
storm collar and vent cap.
AVINGS*
Page 3
The Proven Performers
Service & installation ease
All Copper-Fin2 models offer a service friendly design with gas inlet and shutoff cocks, electrical and EMS connections toward the front of the unit, and a slide out control panel. The referenced gas valve design improves operational performance by monitoring the pressure in the sealed combustion chamber to
maintain the optimum air/ fuel mixture.
All models feature alternate air inlet connections for greater installation flexibility. This field convertible option provides the ability to connect the
air inlet on either the right side or the rear of the unit. And the built-in air inlet filter reduces maintenance and improves performance by trapping dust and airborne particulates that can foul the burners and blowers.
You’ll also save installation time and expense with Lochinvar’s direct vent option, featuring our innovative Aire-Lock™ combustion system. The Aire-Lock™ direct vent option allows the installer to vent the products of combustion directly through a side
wall without the use of an auxiliary power vent cap. By using approved vent material and an air intake pipe, this option effectively “detaches” the unit from the mechanical room by pulling all combustion air from outside the building and venting all combustion by-products outside through a side wall. A feature that can really simplify an installation while reducing overall installed costs.
The enhanced operator interface panel provides fingertip control of the built-in digital temperature controller and can
monitor up to four temperature readouts; inlet, outlet, pool and system temperature with the ability to adjust pool temperature. Its refined user friendly design simplifies service by providing “slide-out” access to electronics and controls.
Flexible Venting Options
Conventional
Vents into conventional flue or vent breaching using Type B double wall vent.
DirectAire Vertical with Sidewall Inlet
Draws fresh air from outside and vents through conventional vertical flue.
Sidewall (CP501 - 751)
Draws fresh air from inside the room. Vents to 50 equivalent feet through the outside wall without the need for a powered sidewall cap.
up
directly
Power DirectAire Horizontal
Draws fresh air from outside and vents through sidewall using optional powered vent cap.
Outdoor
Requires optional outdoor vent cap. Use when indoor space is a problem or if outdoor location gives better access.
DirectAire Vertical
Draws fresh air from outside and vents through conventional vertical flue.
Aire-Lock Direct Vent
Utilizes sealed Aire-Lock combustion system to draw fresh air 50 equivalent feet from a sidewall. Vents horizontally up to 50 equivalent feet through the sidewall using Category IV approved vent material.
Power Sidewall
Vents directly through the outside wall using an optional powered sidewall cap. Ideal when a vent stack is not practical.
Page 4
Commercial Gas Heater Dimensions & Specifications
GAS
Model Btu/hr Btu/hr Vent Air Gas Shipping Number Input Output A B C D E F G H J K L M N P Q R Size Inlet Conn Weight
CPN501 500,000 445,000 31-1/2” 45-1/2” 22-1/4” 38” 20-1/4” 26-1/2” 29” 23” 7” 12-3/4” 38” 38” 8” 9” 41-1/4” 9-3/4” 6” 6” 1-1/4” 480 CPN651 650,000 578,500 31-1/2” 56-3/4” 22-1/4” 38” 20-1/4” 26-1/2” 29” 23” 8-1/2” 12-3/4” 38” 38” 8” 9” 41-1/4” 9-3/4” 8” 8” 1-1/4” 550 CPN751 750,000 667,500 31-1/2” 64” 22-1/4” 38” 20-1/4” 26-1/2” 29” 23” 8-1/2” 12-3/4” 38” 38” 8” 9” 41-1/4” 9-3/4” 8” 8” 1-1/4” 605 CPN0991 990,000 881,100 36” 48-1/4” 33-1/2” 48-1/4” 26-3/4” 30-1/4” 34” 27” 8” 18-1/4 “ 42” 48” 9-1/4” 13” 52” 13-1/4” 10” 10” 2” 930 CPN1261 1,260,000 1,121,400 36” 58-1/2” 33-1/2” 48-1/4” 26-3/4” 30-1/4” 34” 27” 9” 18-1/4 “ 42” 48” 9-1/4” 13” 52” 13-1/4” 12” 12” 2” 995 CPN1441 1,440,000 1,281,600 36” 68-3/4” 33-1/2” 48-1/4” 26-3/4” 30-1/4” 34” 27” 9” 18-1/4 “ 42” 48” 9-1/4” 13” 52” 13-1/4” 12” 12” 2” 1,130 CPN1801* 1,800,000 1,602,000 36” 82-1/4” 33-1/2” 48-1/4” 26-3/4” 30-1/4” 34” 27” 10” 18-1/4 “ 42” 48” 9-1/4” 13” 52” 13-1/4” 14” 12” 2” 1,285 CPN2071* 2,070,000 1,842,300 36” 92-1/2” 33-1/2” 48-1/4” 26-3/4” 30-1/4” 34” 27” 10” 18-1/4 “ 42” 48” 9-1/4” 13” 52” 13-1/4” 14” 12” 2” 1,400
Notes: Change ‘N’ to ‘L’ for LP gas models. . No deration on LP models. Water connections for models CP501-751 are 2” flanged. Water connections for models CP991-2071 are 2-1/2” flanged Performance data is based on manufacturer test results. *Cupro Nickel Heat Exchanger is standard on these models.
Standard Features
Up to 89% Thermal Efficiency
Digital Operator Interface
Less Than 20 ppm NOx Rating
ASME Gasketless Copper Finned-Tube
Heat Exchanger (CP501-1441)
ASME Gasketless Cupro Nickel Finned-Tube
Heat Exchanger (CP1801-2071)
High Temperature CPVC Automatic Pumped Bypass
Flanged Inlet/Outlet Fittings
Loch-Heat™ Ceramic Tile Sealed
Combustion Chamber
Combustion Air Filter
Field Convertible Air Inlet Connection
Programmable Temperature Setpoint
Inlet & Outlet Temperature Sensor
Pool Temperature Sensor
Hot Surface Ignition System
Stainless Steel Burners
Referenced Gas Valves
ASME 160 psi Working Pressure
110°F Safety Limit
24V Controls
Flow Switch
Air Pressure Switch
Remote Control Compatible
Adjustable High Limit w/ Manual Reset
150 psi ASME Temperature and Pressure
Relief Valve
Slide-Out Control Panel with
Plug-In Components
5-Year Limited Warranty on Heat Exchanger
(See warranty for details)
Optional Equipment
Alarm Bell
Cupro Nickel Heat Exchanger (CP501-1441)
High Gas Pressure Switch w/ Manual Reset
Low Gas Pressure Switch w/ Manual Reset
Stack Frame (Horizontal Bypass Only)
Pump Delay
Pump Purge w/ Maintenance Timer
Vertical Mounted Pumped Bypass
Available Firing Systems
F9 Electronic Control with Hot-Surface Ignition (Standard) F7 California Code
Venting Options
Aire-Lock Direct Vent
Sealed Combustion
Conventional
DirectAire® Vertical
DirectAire® Vertical
w/ Sidewall Inlet
Outdoor
Powered DirectAire® Horizontal
Powered Sidewall
Sidewall (CP501-751)
Registered under patent #5,989,020
FOR EASE IN ORDERING
BY MODEL NUMBER
CP N 501 F9
MODEL
FUEL TYPE
This heater is 500,000 Btu/hr natural gas
Copper-Fin
2
pool heater. It has F9 firing controls.
Btu/hr
INPUT
CONTROLS
FIRING
Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
CPN-11 (Replaces CPN-10)
www.Lochinvar.com
FG-5M-1/11 Printed in U.S.A.
Loading...