Lochinvar CHXkW 005A User Manual

COMPACT ASME HI-POWER
®
WATER HEATER
Submittal Sheet
HPC-Sub-03d
COMPACT ASME HI-POWER® COMMERCIAL ELECTRIC WATER HEATERS
JOB NAME ______________________________________________________________________ LOCATION ______________________________________________________________________ ARCH./ENGR.____________________________________________________________________ WHOLESALER __________________________________________________________________ MECH. CONTRACTOR ___________________________________________________________ MODEL NO. _____________________________________________________________________ RECOVERY RATE IN GPH_______________________________________@________°F RISE GALLON CAPACITY_____________________________________________________________ VOLTAGE/PHASE________________________________________________________________ KW_____________________________________________________________________________ NOTES
Standard Features
• Meets ASHRAE Energy Efficiency Standards
• ASME Code Construction HLW
• 150 psi working pressure for 5 thru 50 gallon models.
• 125 psi working pressure for 65 thru 120 gallon models.
• Tank Saver Anode & Powered Anode
• Low Watt Incoloy Heating Element
• Energy Cut-Off
• Low Water Cut Off
• Enable / Disable Contacts
• Night Setback
• Internal Fusing
• 180 °F Operation Approved
• ASME Temperature and Pressure Relief Valve
• Non-CFC Foam Insulation
• Hinged Access Door
• Immersion Thermostats with Contactors
• 3 Year Limited Tank Warranty
• 1 Year Limited Parts Warranty (See warranty for details)
Optional Equipment
Place an X in the box by all options that apply.
Alarm Horn High Water Pressure Limit Switch Low Water Pressure Limit Switch Temperature & Pressure Gauge 150 PSI Working Pressure 4” x 6” Handhole Cleanout Pilot Light & Switches Modulating Control
*Note: T&P relief valve supplied, not factory mounted
Dimensions & Specifications
Model Gallon Maximum Water Shipping Number Capacity kW A B C D Conn. Weight
CH(X)kW 005A 5 3 20-1/2” 16-1/4” 22-1/2” 5-1/4” 3/4” 100 CH(X)kW 010A 10 6 26-1/4” 18-3/4” 25” 5-1/4” 3/4” 116 CH(X)kW 020A 20 18 27-1/4” 20-1/2” 26-1/2” 5-3/4” 3/4” 145 CH(X)kW 030A 30 24 35-3/4” 20-1/2” 26-1/2” 5-3/4” 3/4” 168 CH(X)kW 040A 40 36 45-3/4” 20-1/2” 26-1/2” 5-3/4” 3/4” 206 CH(X)kW 050A 50 90 54-3/4” 20-1/2” 26-1/2” 5-3/4” 3/4” 235 CH(X)kW 065A 65 90 54” 26-1/2” 33-1/2” 7” 1-1/4” 280 CH(X)kW 080A 80 90 52-1/4” 28” 35” 7” 1-1/4” 300 CH(X)kW 100A 100 90 60-1/2” 28” 35” 7” 1-1/4” 354 CH(X)kW 120A 120 90 65-1/2” 30” 37” 7-1/2” 1-1/4” 430
NOTE: Allow 24” clearance from front access panel for service and maintenance.
VOLTAGE SCHEDULE
A - 240V / 1 PH Z - 415V / 3 PH J - 280V / 1 PH V - 480V / 1 PH K - 208V / 3 PH X - 480V / 3 PH B - 240V / 3 PH M - 575V / 3 PH W - 277V / 1 PH N - 600V / 3 PH Y - 380V / 3 PH
C
Amperage Table
SINGLE PHASE THREE PHASE kW 208V 240V 277V 480V 208V 240V 480V
3 14.4 12.5 10.8 6.3 8.3 7.2 3.6 6 28.8 25.0 21.7 12.5 16.7 14.4 7.2 9 43.3 37.5 32.5 18.8 25.0 21.7 10.8 12 57.7 50.0 43.3 25.0 33.3 28.9 14.4 15 72.1 62.5 54.2 31.3 41.6 36.1 18.0 18 86.5 75.0 65.0 37.5 50.0 43.3 21.7 24 115.4 100.0 86.6 50.0 66.6 57.7 28.9 30 144.2 125.0 108.3 62.5 83.3 72.2 36.1 36 173.1 150.0 130.0 75.0 99.9 86.6 43.3 45 216.3 187.5 162.5 93.8 124.9 108.3 54.1 54 N/A 225.0 194.9 112.5 149.9 129.9 65.0 60 N/A 250.0 216.6 125.0 166.5 144.3 72.2 75 N/A N/A N/A 156.3 208.2 180.4 90.2 90 N/A N/A N/A 187.5 249.8 216.5 108.3
Note: All ASME models with an amp draw in excess of 120 amps recieve factory installed internal fusing. Note: Outlet connection for 5 thru 50 models 3/4” NPT.
GPH Recovery Rate
INPUT Recovery Rate ( GPH @ °F Rise) kW Btu/hr 30°F 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F
3 10,239 41 31 34 20 17 15 13 12 11 10 10 9 6 20,478 82 62 49 41 35 31 27 25 22 21 19 18 9 30,717 123 92 74 62 53 46 41 37 34 31 28 26 12 40,956 164 123 98 82 70 61 55 49 45 41 38 35 15 51,195 205 154 123 102 88 77 68 61 56 51 47 44 18 61,434 246 184 148 123 105 92 82 74 67 62 57 53 24 81,912 328 246 197 164 140 123 109 98 90 82 76 70 30 102,390 410 308 246 205 176 154 137 123 112 103 95 88 36 122,868 492 369 295 246 211 184 164 148 134 123 113 105 45 153,585 615 461 369 307 263 230 205 184 168 154 142 132 54 184,302 738 554 443 359 316 277 246 221 201 185 170 158 60 204,780 819 615 492 410 351 307 273 246 223 205 189 176 75 255,975 1,025 768 615 512 439 384 341 307 279 256 236 219 90 307,710 1,229 922 738 615 527 461 410 369 335 307 284 263
A
B
Outlet connection for 65 thru 120 models 1-1/4” NPT.
OUTLET
3/4” NPT RELIEF VALVE OPENING
CONDUIT OPENING
HINGED ACCESS DOOR
D
HLW
Lochinvar, LLC • 300 Maddox Simpson Pkwy• Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
www.Lochinvar.com
(Web Updated 8/12) - 10/11—Printed in U.S.A.
Loading...