Lochinvar AWN151PM User Manual

ARMOR
Condensing Water Heater
Submittal Sheet
AWP-Sub-08
ARMORTM CONDENSING WATER HEATER PACKAGE SYSTEM
JOB NAME ______________________________________________________________________ LOCATION ______________________________________________________________________ ENGINEER____________________________________________________________________ WHOLESALER __________________________________________________________________ MECH. CONTRACTOR ___________________________________________________________ MODEL NO. _____________________________________________________________________ TYPE GAS ______________________________________________________________________ Btu/hr INPUT_____________________________________________________________________ RECOVERY RATE IN GPH_______________________________________@________°F RISE NOTES
Standard Features
> Up to 97% Thermal Efficiency > Modulating Burner with 5:1 Turndown > Direct-Spark Ignition > Low NOx Operation > Sealed Combustion > Low Gas Pressure Operation
> Vertical & Horizontal Direct-Vent
> PVC, CPVC, Polypropylene or SS Venting up to 100 Feet > PVC/CPVC Sidewall Vent Termination
> Stainless Steel Heat Exchanger
> All Welded Construction, Gasketless Design > 160 psi Working Pressure > ASME Construction (AW 286-801) > Natural to L.P. Conversion Kit > All Bronze Circulating Pump > On/Off Switch > Flow Switch > ASME Temperature & Pressure Relief Valve (286-801) > Temperature & Pressure Gauge (AW 501-801) > Downstream Test Valves (AW 501-801) > Adjustable Leveling Legs > Tank Sensor
> Adjustable High Limit w/ Manual Reset > Automatic Reset High Limit > Condensate Trap > Zero Clearances to Combustible Material > 5 Year Limited Warranty (See Warranty for Details)
> 1 Year Parts Warranty (See Warranty for Details)
Smart System Features
> SMART SYSTEM Digital Operating Control > Multi Color Graphic LCD Display > Built in Cascading Sequencer for up to 8 Water Heaters > Lead Lag > Efficiency Optimization > Building Management System Integration > Modbus Communication (Optional) > 0-10VDC Input to Control Modulation or Set point > 0-10VDC Modulation Rate Output > 0-10VDC Input to Enable/Disable call for heat > Access to BMS Settings Through Graphic LCD Display > Low Water Flow Safety Control & Indication > Inlet & Outlet Temperature Sensors & Readout > Flue Temperature Sensor > Water Heater Pump Control > Pump Delay with Freeze Protection > Pump Exercise > Night Setback > Building Recirculation loop Pump Control* > Night Setback of Building Recirculation Loop* > Time Clock > Maintenance Reminder > Ability to program name and number into the product
as contact
> High Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply > Pump Control Contacts > Water Heater Pump Control Contacts > Building Recirculation Pump Control Contacts > Low Voltage Terminal Strip > 24 VAC Auxiliary Device Relay > Auxiliary Proving Switch Contacts > Flow Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > Tank Sensor Contacts > Cascade Contacts > 0-10 VDC BMS External Control Contact > 0-10VDC Boiler Rate Output Contacts > Modbus Contacts
*Exclusive to Lochinvar
Optional Equipment
> Alarm Bell > Condensate Neutralization Kit
> High & Low Gas Pressure Switches (AW
501-801)
> Concentric Vent Kit
(3” & 4” PVC/CPVC only) > ModBus Communications > BMS Gateways for LonWorks or BACnet > SMART SYSTEM PC Software > Room Air Vent Kits > Stack Frame
Firing Control Systems
> M9 Standard Construction > M7 California Code
(AW 286-801)
> M13 CSD1 / FM / GE Gap
(AW 501-801)
ARMOR Condensing Water Heater Dimensions & Specifications
TNORF
"4/3 7
"2/1 51
"4/1 11
H
"4/3 92
"4/1 03
J
"2/1 51
I
K
"4/3 3 G
F
E
D
C
"2/1 6
A
"4/1 1 - "4/1
ELBATSUJDA
TELNI RIA
EULF
LACIRTCELE
SNOITCENNOC
SAG
TELNI
TELTU
O
NIARD
TPN "4/3
ETASNEDNOC
NIARD
TNORF
"8
"2/1 51
"93
"2/1 93
"4/3 31
I
K
"4/3 81
H
J
"
4/3 3
G
F
D
E
C
"9
A
"4/1 1 - "4/1
ELBATSUJDA
TELNI RIA
EULF
LACIRTCELE
SNOITCENNOC
SAG
TELNI
TELTU
O
NIARD
TPN "4/3
ETASNEDNOC
NIA
RD
Models 151-200
Models 286-801
Model Btu/hr GPH @ Gas Water Air Vent Shipping Number Input 100° Rise A C D E F G H I J K Conn. Conn.
AWN151PM 150,000 173 33-1/4” 18” 12-1/4” 11-1/2” 10” 1-1/2” 21-1/4” 23” 1-3/4” 12” 1/2” 1-1/4” 3” 3” 165 AWN200PM 199,999 235 33-1/4” 22-1/4” 16-1/2” 15-3/4” 14-1/4” 5-1/4” 21-1/4” 23” 1-3/4” 16-1/4” 1/2” 1-1/4” 3” 3” 181 AWN286PM 285,000 332 42-1/2” 19-3/4” 12-3/4” 13-1/2” 6” 2” 34” 31” 11-3/4” 4-1/4” 3/4” 2” 4” 4” 236 AWN400PM 399,999 465 42-1/2” 27” 21” 20-3/4” 14” 3-1/2” 34” 34” 18-3/4” 2” 1” 2” 4” 4” 292 AWN501PM 500,000 582 42-1/2” 31-1/2” 21” 25” 14” 3-1/2” 35” 35” 22” 5-3/4” 1” 2” 4” 4” 333 AWN601PM 600,000 698 42-1/2” 36-1/4” 25” 21” 14” 3-1/2” 36” 32-3/4” 19-1/2” 5-1/2” 1-1/2” 2” 4” 4” 380 AWN701PM 700,000 815 42-1/2” 40-1/4” 29” 23” 17” 3-1/2” 36” 32-3/4” 23-1/2” 3-1/4” 1-1/2” 2” 4” 6” 461 AWN801PM 800,000 931 42-1/2” 45-1/4” 33-1/4” 23” 17” 3-1/2” 36” 32-3/4” 27-3/4” 3-1/4” 1-1/2” 2” 4” 6” 527