Lochinvar AMP 200-9, AMP 200-18, AMP 300-9, AMP 300-18, AMP 200-36 Maintenance Manual

...
Cavalier Electric Water Heater
Installation, Commissioning, User & Maintenance Instructions
LV 313545 | February 2020
Models: AMP 200-9 AMP 200-18 AMP 200-36
Models:
AMP 300-9 AMP 300-18 AMP 300-36 AMP 300-54
0313545 R2.0 / 0620 - Changes Reserved
IMPORTANT INFORMATION
!
These instructions must be read and understood before installing, commissioning, operating or maintaining the equipment.
0313545_AMP_UKUK_V2.0, 03-02-2020 3
Preface
Copyright
Copyright © 2019 Lochinvar Ltd.
All rights reserved.
Nothing from this publication may be copied, reproduced and/or published by means of printing, photocopying or by whatsoever means, without the prior written approval of Lochinvar Ltd..
Lochinvar Ltd. reserves the right to modify specifications in this manual.
Trademarks
Brand names in this manual are registered trademarks of their respective owners.
Warranty
Refer to the appendix Warranty (see 11.6) for the warranty provisions.
Liability
User
Lochinvar accepts no liability when the water heater is not used correctly and requires the user to:
Read this manual carefully and obey the instructions.
Ask your installation engineer for advise about the use of the water heater.
Make sure that the service and maintenance activities are done by a qualified engineer.
Installation engineer
Lochinvar accepts no liability when the water heater is not used correctly and requires the installation engineer to:
Read this manual carefully and obey the instructions.
Make sure that the entire water heater installation complies with the applicable regulations.
Make sure that the water heater is tested before the installation is taken into use.
Explain the correct use to the user.
Notify the user when service and maintenance activities are necessary.
Make sure that you hand over all applicable manuals.
Supplier
The AMP water heater is designed in accordance with the applicable regulations. The water heater is delivered with all necessary documentation to obey these regulations.
Lochinvar accepts no liability for claims from third parties when:
The instructions for the correct installation of the water heater are not obeyed.
The instructions for the correct use of the water heater are not obeyed.
The water heater did not have maintenance at the correct maintenance interval.
For more information, refer to the General Terms of Sales. These are available on request, free of charge.
We believe that this manual provides you with accurate and complete descriptions of all relevant components. If you, nonetheless find errors or inaccuracies in this manual, please inform Lochinvar. This helps us to further improve our documentation.
Compliance
To safely produce domestic hot water, the design and construction of the AMP water heaters is in accordance with:
The LVD Directive (2006/95/EC)
The European Pressure Equipment Directive
The European ECO-Design Directive.
The European Energy Labeling Directive
Refer to the appendix Declaration of conformity (see 11.5).
Regulations
The installation of the equipment MUST be in accordance with the relevant requirements of the Building Regulations, I.E.E. Regulations and the bylaws of the local water undertaking.
In addition, the installation should follow the relevant guidance offered in the following documents. It is not practical to list all relevant information due to continuous changes but emphasis is placed on the following documents,
4
as failure to comply with the guidance given will almost certainly result in an unsatisfactory installation:
British Standards (BS), especially:
- BS 6700: 1997 - Design, installation, testing and maintenance of services supplying water for domestic use with buildings and their curtilages
- BS 67074: 1989 Part 1 and 2 ­Application, selection and installation of expansion vessels and ancillary equipment for sealed systems
- BS 7671: 2008 - Requirements for electrical installations, I.E.E. wiring regulations seventeenth edition
- CP 342: Part 2 1974 - Code of practice for centralised hot water supply-buildings other than dwellings
CIBSE Guides
Clean Air Act
H.S.E Guidance
Note
Manufacturer's notes must not be taken in any way as overriding statutory obligations.
Contact information
In the event of problems with your electricity or water supply connections or when you have any comments or questions, please contact your supplier.
About this manual
Scope
This manual gives information about safe and correct use of the water heater and how installation, maintenance and service activities have to be done correctly. You must obey the instructions in this manual.
Caution
Read this manual carefully before you start the water heater. It can cause personal injury and damage to the water heater when you do not read the manual and/or do not obey the instructions.
The purpose of this manual is to:
describe the working principles and layout of the water heater
explain the safety devices
highlight possible hazards
describe the use of the water heater
describe the installation, service and maintenance of the water heater
This manual has two parts:
A User part that describes the correct usage of the water heater.
An Installation, Maintenance and Service part, that describes the correct installation and maintenance procedures.
Target group
The information in this manual applies to three target groups:
users
installation engineers
service and maintenance engineers
The User part is intended for the (end) users. The Installation, Maintenance and Service part is intended for the installation engineers and the service and maintenance engineers.
Notation conventions
This manual uses the following text conventions:
Numbers between parentheses e.g. (1), refer to elements in a figure that are described by the text.
Cross-references to sections, tables, figures etc. are underlined and written as (see "..."). In the digital version, the cross-references function as hyperlinks that can be used to navigate through the manual by clicking on them. Example: Safety (see 2).
This manual contains the following text styles for situations that may endanger users/ engineers, cause damage to equipment or need special attention:
Note
A note gives more information on a topic.
0313545_AMP_UKUK_V2.0, 03-02-2020 5
Caution
Obey the caution instructions to prevent damage of the water heater.
Warning
Obey the warning instructions to prevent danger of personal injury, and serious damage to the water heater.
Danger
Obey the danger instructions to prevent danger of serious personal injuries or death, and serious damage to the water heater.
Table of contents
Preface ............................................................ 3
Copyright .................................................... 3
Trademarks ................................................ 3
Warranty ..................................................... 3
Liability ....................................................... 3
Compliance ................................................ 3
Regulations ................................................ 3
Contact information .................................... 4
About this manual .......................................... 4
Scope ......................................................... 4
Target group ............................................... 4
Notation conventions .................................. 4
User Part.......................................................... 6
1 Introduction .............................................. 6
2 Safety ........................................................ 6
3 Operation .................................................. 7
3.1 Control components.......................... 7
3.2 Status of the water heater ................. 7
4 Use ............................................................ 7
4.1 Turn on the water heater................... 7
4.2 Turn off the water heater................... 8
Installation, Maintenance and Service Part ... 8
5 Introduction .............................................. 8
5.1 About the water heater ..................... 8
5.2 Working principle .............................. 8
6 Safety ......................................................... 8
6.1 Safety instructions ............................. 8
6.2 Instructions on the water heater ........ 9
6.3 Safety devices .................................. 9
6.4 Environmental aspects .................... 11
7 Water heater ............................................ 11
7.1 Structure of the water heater ........... 11
8 Installation ............................................... 11
8.1 Packaging ....................................... 11
8.2 Conditions ....................................... 11
8.3 Installation diagram ......................... 12
8.4 Water connections .......................... 13
8.5 Electrical connections ..................... 13
8.6 Commissioning ............................... 14
8.7 Decommisioning ............................. 14
9 Maintenance ............................................ 14
9.1 Performance check ......................... 15
9.2 Water-side maintenance ................. 15
10 Troubleshooting...................................... 16
10.1 General errors ................................. 16
11 Appendices ............................................. 17
11.1 Technical Data ................................ 17
11.2 Dimensions ..................................... 18
11.3 EcoDesign Data .............................. 19
11.4 Electrical diagram ........................... 20
11.5 Declaration of conformity ................ 23
11.6 Warranty ......................................... 24
6 Installation, Commissioning, User & Maintenance Instructions
User Part
1 Introduction
The AMP water heater stores and heats water for sanitary purposes.
Cold water enters the tank through the water inlet (2). The heated water leaves the tank at the top through the hot water outlet (1). When hot water is used, the tank of the water heater is filled with the same amount of cold water.
To operate the water heater, the regulation thermostat, on each heating element, is used.
Fig. AMP water heater
1. Water outlet
2. Water inlet
2 Safety
Lochinvar cannot be held responsible for damages or injuries due to to:
Failing to follow the instructions provided in this manual.
Carelessness during use or maintenance of the water heater.
Every user must study the user part of this manual and must follow the instructions in this part of the manual strictly. Do not change the sequence of the described actions. This manual must be available for the user and service engineer at all times.
Warning
If you detect a burning smell:
-
Shut off the mains power supply
-
No naked flames! No smoking!
-
Open windows and doors!
-
Warn occupants and leave the building!
-
After leaving the building, alert your installation engineer.
Caution
Do not store or use chemical substances in the room where the water heater is installed because of the risk of explosion and corrosion of the water heater. Some propellants, bleaching agents and degreasing agents etc. disperse of explosive vapors and/or cause accelerated corrosion. If the water heater is used in a room where such substances are stored or used, the warranty will be void.
Caution
Installation, maintenance and service may only by carried out by a qualified engineer.
Caution
The water heater is not intended for use by persons with reduced physical, sensory or mental capacities, or who lack the necessary experience or knowledge.
When the person responsible for their safety is supervising or has explained how the water heater should be used, these persons can use the water heater.
0313545_AMP_UKUK_V2.0, 03-02-2020 7
Caution
This water heater is not intended to be used by children. Always supervise children, and make sure that they do not play with the water heater.
Note
Regular maintenance extends the service life of the water heater. To determine the correct service interval, the service and maintenance engineer must do a check on the water heater three months after installation. Based on this check, the best service interval can be determined.
3 Operation
3.1 Control components
To set the temperature of the AMP water heater, use the control knob of the regulation thermostat. Each electric heating element has a regulation thermostat with a control knob.
3.1.1 Temperature control
With the temperature control knob, of each regulation thermostat, you can set the desired water temperature of the water heater (see
4.1.1).
Note
It is not possible to use the temperature control knob to activate and de-activate the water heater.
3.2 Status of the water heater
The water heaters has 2 opertaion modes.
3.2.1 Operating modes
The AMP has 2 operating modes:
OFF mode (see 3.2.1.1)
ON mode (see 3.2.1.2)
3.2.1.1 OFF mode
In the OFF mode the water heater is de-activated. The main power supply of the water heater is set to 0.
In the OFF mode the water heater is not protected against frost.
3.2.1.2 ON mode
In the ON mode the water heater continuously responds to the heat demand. The electric heating elements are activated when there is a heat demand.
4 Use
4.1 Turn on the water heater
Caution
Make sure that the water heater is filled with water before you turn on the water heater.
To start the water heater:
1. Put the water heater in the OFF-mode
2. Open the door of the water heater.
3. Remove the foam so the controls of the water heater become visible.
4. Turn the temperature control knob of each heating element to the desired temperature.
5. Replace the foam over the controls
6. Close the door of the water heater.
7. Turn on the main power supply.
4.1.1 Temperature setting
Note
Changing the set temperature is an operation that must be carried out by a qualified service engineer/installer. Before attempting to change the temperature the appliance must be isolated from the Electric supply (OFF-mode) before the door to the controls may be opened.
Temperature in °F
Temperature in °C
120
49
130
54
140
60
150
66
160
71
170
77
180
82
8 Installation, Commissioning, User & Maintenance Instructions
Caution
Preferably the temperature control knob, on each thermostat, should be set to 60°C.
Harmful scaling and lime build-up will be higher when using position 65°C and higher. At lower temperature settings there is a higher risk of high legionella concentrations in the water.
4.2 Turn off the water heater
2.2.1 Turn off for a short period
To turn off the water heater for less than 2 months, set the water heater in the O FF mode (see 3.2.1.1).
2.2.2 Turn off for a long period
When the water heater needs to be turned off for more than 2 months, contact your service and maintenance engineer to decommission the water heater.
Installation, Maintenance and Service Part
5 Introduction
5.1 About the water heater
The AMP water heater is intended for heating water for sanitary purposes.
The AMP is a electric storage water heater. The electric heating elements transfer their heat directly to the water.
5.2 Working principle
Cold water enters the tank through the water inlet. When the water temperature drops beneath the set temperature, the electrical heating elements are activated and the water is heated. The heating elements directly transfer the heat to the water and the hot water leaves the tank through the water outlet.
The tank of the water heater has to be completely filled during operation. The tank at least must remain under mains water supply pressure at any time. Fresh cold water is immediately added when hot water is drawn from the water heater. The regulation thermostat on each heating element, is equipped with a contact thermostat. This thermostat measures the water temperature, on the outside of the tank.
6 Safety
6.1 Safety instructions
For safety instructions on the use of the water heater, refer to Safety (see 2) in the User part of this manual.
Warning
Installation, maintenance and service must be carried out by a qualified engineer in compliance with the national and local regulations.
Warning
This appliance must be installed on a non­flammable floor or surface.
Caution
The water heater may only be moved in an upright position. After unpacking, make sure that the water heater is not damaged.
Caution
Fill the water heater completely before use. Dry firing will damage the water heater.
Note
Any leakage from the tank and/or connections can cause damage to the immediate environment or floors below the level of the installation room. Install the water heater above a waste water drain or in a suitable metal leak tray.
The leak tray must have an appropriate waste water drain and must be at least 5 cm deep with a length and width of at least 5 cm larger than the water heater.
0313545_AMP_UKUK_V2.0, 03-02-2020 9
6.2 Instructions on the water heater
The water heater has some safety instructions on its cover: The text "A pressure relief valve must be
fitted".
The text "Mount the delivered temperature
and pressure valve in this connection".
The text "Check screwed wire connections".
6.3 Safety devices
Safety devices of the water heater:
Float switch
(boil dry protection)
The float switch monitors the water level, approximately halfway up the tank, above the elements. If there is insufficient water present in the tank, then the float hangs down (reed-contact open). If the tank is filled with water then the float is moved upwards by the water (reed-contact closed).
Overheat thermostat
The overheat thermostat detects the temperature of the water in the tank. When the temperature become too high (>93°C) the thermostat locks the elements. The thermostat can be manually reset (red button) when the temperature of the water is below 20°C.
Safety devices of the installation:
Expansion valve
The expansion valve is a pressure relief valve. The expansion valve prevents excessive pressure in the tank and back flow of expansion water into the cold water main supply.
Non-return valve
The non-return valve prevents back flow of expansion water into the cold water main supply.
Pressure-reducing valve
The pressure-reducing valve reduces the water mains pressure, if necessary.
Expansion vessel
The expansion vessel is a small tank that is used to protect closed water systems from excessive pressure, due to thermal expansion of the water in the tank.
T&P valve
(1)
(Temperature and pressure relief valve)
The T&P valve is a temperature and pressure relief valve which is activated when:
- The temperature exceeds 97°C.
- The pressure exceeds 7 bar.
1- All water heaters have a T&P valve connection. Lochinvar recommends to always use a T&P valve.
6.3.1 Boil Dry Protection
The boil dry protection mechanism is a float switch which monitors the water level approximately halfway up the tank above the elements. If there is insufficient water present in the tank, the float (1) hangs downwards. If the tank is filled with water then the float is moved upwards by the water.
6.3.1.1 Working principle
The working principle is as follows: the float arm moves a magnet that is in contact with a reed­contact, which is located in the black plastic tube at the end of the float switch. The movement of the magnet and float arm changes the magnetic field and the reed-contact is opened or closed.
Loading...