Lochinvar CBN1257, 673 1, CBN2067, CBN1437, CBN1797 User Manual

...
Energy Efficient, Cost Effective Boilers
Lochinvar first introduced Copper-Fin technology to the boiler industry some 50 years ago. Since then, we’ve continued to refine and perfect it - adding advanced fan-assisted combustion, hot surface ignition, a unique gasketless cop per finned tube heat ex chang er and highly efficient insulating materials.
Installation Flexibility and Cost-Savings
With compact sizes that use less floor space than ever before, all Copper-Fin units are narrow enough to fit through a standard 36” doorway – an ad van tage most commercial boilers can’t provide. Plus, thanks to special insulating materials, Copper-Fin units require only 3” clearance from combustible walls. What’s more, our Stack Frame allows you to install two units in the area normally required for one. This makes it easier to fit multiple Copper-Fin boilers into cramped me chan i cal rooms. And you can even use a smaller diameter vent stack - up to 8” smaller than typically required for comparable atmospheric boilers - so it saves money as well as valuable mechanical room space.
Unique Copper-Fin Heat Ex chang er
The Lochinvar Copper-Fin boiler design uses a two
pass heat ex chang er. Water is circulated through
a row of high ly-efficient, finned copper tubes.
The high rate of water flow creates a
scour ing action that prevents sed i ment
and lime-scale buildup, common
in conventional boilers, and
the finned copper tubes
allow maximum heat
transfer efficiency. To create this special
heat transfer capability,
Lochinvar extrudes the fins
from thick wall copper tubing to
precise specifications - ex act ly 7 fins per inch. The result is an integrally-finned tube with a heat transfer ratio 9 times greater than a plain copper tube.
Heavy-Duty Gasketless Design
What’s more, advanced casting processes allowed Lochinvar to develop a unique one-piece header system. This gasketless design provides enhanced reliability, improved durability and optimum performance - without the problems or failures common with O-rings and gaskets.
Meets the Toughest Air Quality Standards
Because of our unique fan-assisted combustion
process, the Copper-Fin exceeds today’s toughest
NOx emissions requirements. An independent
certification laboratory test gave us a rating of
less than 20 ppm - corrected to 3% O
NOx means a cleaner environment.
. And less
2
Enhanced to Provide Performance and Serviceability
Our enhanced Copper-Fin models offer the same reliable operation, and feature a more service friendly design. The down stream test valves and referenced gas valves are now in the upper deck for easier access, and the electrical and BMS connections have been repositioned to the front of the unit for easier installation.
The gas valves, which are referenced to the sealed combustion chamber, improve operational performance by monitoring the pressure in the sealed combustion chamber and adjusting gas flow to maintain the optimum air/fuel mixture. And the built-in air inlet filter reduces maintenance and improves performance by trapping dust and airborne particulates that can foul the burners and blowers. With dual sight glasses (one on each end), you can easily monitor burner performance and flame characteristics throughout the entire combustion chamber.
The operator interface panel provides two-stage electronic temperature control and comprehensive diagnostic status without opening the control panel. Its user friendly design simplifies service while providing additional diagnostic information through a series of LEDs.
Vent Cost-Savings
Btu/hr CONVENTIONAL COPPER-FIN INPUT VENT SIZE VENT SIZE $ S
495,000 10” 6” $ 382 645,000 12” 8” $ 504 745,000 14” 8” $ 829 985,000 16” 10” $ 1,228 1,225,000 16” 12” $ 992 1,435,000 18” 12” $ 1,466 1,795,000 20” 14” $ 1,564 2,065,000 22” 14” $ 2,398
*Comparison based on 25´ vent system using Type “B” double wall vent material,
storm collar and vent cap.
Copper-Fin
®
Commercial Gas Boilers
AVINGS*
Copper-Fin® Boiler Dimensions & Specifications
Copper-Fin Heating Boiler Dimensions & Spec i fi ca tions
Input Heating Net Model Max Thermal Capacity I=B=R Gas Vent Shipping Number MBH Efficiency MBH MBH A B C D E F G Conn. Size Weight
CBN0497 495 81% 401 349 31-1/2” 45-1/4” 22-1/4” 12-1/2” 9-1/2” 22-3/4” 29-1/2” 1-1/4” 6” 440 CBN0647 645 81% 522 454 31-1/2” 56-3/4” 22-1/4” 12-1/2” 9-1/2” 28-1/2” 29-1/2” 1-1/4” 8” 510 CBN0747 745 81% 603 524 31-1/2” 64” 22-1/4” 12-1/2” 9-1/2” 32” 29-1/2” 1-1/4” 8” 550 CBN0987 985 81% 798 694 36” 48-1/4” 33-1/2” 15-3/4” 8-1/2” 8-1/2” 33-3/4” 2” 10” 845 CBN1257 1255 81% 1,017 884 36” 58-1/2” 33-1/2” 15-3/4” 9-1/2” 10-1/2” 33-3/4” 2” 12” 905 CBN1437 1435 81% 1,162 1,010 36” 68-3/4” 33-1/2” 15-3/4” 10-1/2” 10-1/2” 33-3/4” 2” 12” 1050 CBN1797 1795 81% 1,454 1,264 36” 82-1/4” 33-1/2” 15-3/4” 11” 11” 33-3/4” 2” 14” 1193 CBN2067 2065 81% 1,673 1,455 36” 92-1/2” 33-1/2” 15-3/4” 11” 11” 33-3/4” 2” 14” 1350
Notes: Change ‘N’ to ‘L’ for LP gas models. Water connections for models CB 0497-747 are 2” NPT on 6-1/2” centers. No deration on LP models. Water connections for models CB 0987-2067 are 2-1/2” NPT on 11-1/4” centers. Performance data based on manufacturer test results.
Standard Features
81% Thermal Efficiency
Electronic Temperature Control
Fan Assisted Combustion
Sealed Combustion Chamber
Stainless Steel Burners
Low NOx Operation Exceeds the most
Stringent Air Quality Requirements
ASME Copper Finned Tube
Heat Exchanger
160 psi Working Pressure
Gasketless Heat Exchanger Design
Pump Relay w/ Delay
Down Stream Test Valve
Referenced Gas Valves
Loch-Heat Ceramic Tile
Combustion Chamber
Hot Surface Ignition
Adjustable High Limit w/ Manual Reset
ASME Pressure Relief Valve
Temperature & Pressure Gauge
Flow Switch
24 Volt Control System
BMS Terminal Strip
Combustion Air Filter
Freeze Protection
10 Year Limited Warranty on Heat
Exchanger (See warranty for details)
Optional Equipment
Alarm Bell
Contacts on any Failure
Contacts for Air Louvers
Cupro-Nickel Heat Exchanger
High & Low Gas Pressure Switch
w/ Manual Reset
Outdoor Reset Control
Manual Reset Low Water Cut-Off
w/ test
Stack Frame
MP2 Sequencer
Available Firing Systems
M9 Hot Surface Ignition with Electronic Supervision (Standard) M13 GE GAP/FM/CSD1 M7 California Code
Venting
Outdoor Vent Cap
Registered under U.S. Patent # 5,989,020
For Ease In Ordering
By Model Number
CB N 0497 M9
NAT. GAS
MODEL
This boiler is a 495,000 Btu/hr,
natural gas Copper-Fin. It has M9 firing controls
Btu/hr INPUT
FIRING
CONTROLS
Lochinvar Corporation • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000
CBN-07 (Replaced CBN-06 3/10)
www.Lochinvar.com
FG-10M-5/11-Printed in U.S.A.