Lochinvar 401-751 User Manual

PUMP
Recommendation
PUMP RECOMMENDATION FOR
COPPER-FIN II 401-751 POOL HEATER
Pump Specifications
Part No. HorsePower Flanges Valute Material Flange Material Vendor Vendor Product Series Orientation
Installation Specifications
Recommended for Based on Pump Model Numbers Maximum GPM Installation Type
Copper-Fin II Pool Htr, CP(N,L) 401-751 55 GPM Single Pool Heater piped Primary/Secondary to Pool Loop ARM3044PABTE Based on Based on
Minimum Pipe Diameter Connecting piping
2" Maximum 45 feet straight pipe with 6-Elbows, 2-Unions and 2-Ball Valves
IMPORTANT: Read the Copper-fin II 500-2070 Pool Installation and Operation Manual. If the planned system exceeds the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps and pump curves.
20
15
10
5
TOTAL HEAD IN FEET
0
10
20
30 40 50 60
CAPACITY IN U.S. GALLONS PER MINUTE
12-1/2”
C
OIL PORT
B D
10”
15-3/4”
A
PUMP-Rec-08 Rev C
LS-45
80
90
70
100
110
1
PUMP
PUMP RECOMMENDATION FOR
COPPER-FIN II 0991-1441 POOL HEATER
Pump Specifications
Part No. HorsePower Flanges Valute Material Flange Material Vendor Vendor Product Series Orientation
ARM3024PABTE 1/2 2-1/2" Brass Brass Armstrong 2B1050 Vertical
Installation Specifications
Recommended for Based on Pump Model Numbers Maximum GPM Installation Type
Copper-Fin II Pool Htr, CP(N,L) 0991-1441 90 GPM Single Pool Heater piped Primary/Secondary to Pool Loop ARM3024PABTE Based on Based on
Minimum Pipe Diameter Connecting piping
2-1/2" Maximum 45 feet straight pipe with 6-Elbows, 2-Unions and 2-Ball Valves
IMPORTANT: Read the Copper-fin II 500-2070 Pool Installation and Operation Manual. If the planned system exceeds the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps and pump curves.
19-1/2”
A
16”
C
OIL PORT
B D
11-1/2”
Recommendation