Lobb Wa2700, Wa1, Wa2, Wa1700 Owner's Manual

INTRODUCTION
• LOBB Power Humidifiers are the most versatile, “common sense” designed humidifiers on the market today. They offer you, the homeowner, the most trouble-free, high capacity power humidifiers yet built. Based on the proven high efficiency of the rotating drum principle, these units deliver controlled pure water vapor into the home up to 18 gallons per day.
OPERATING PRINCIPLE: Evaporation takes place as the heated air from your furnace passes through the moisture laden evaporative pad. This pad, is wetted as it slowly rotates in a float controlled level of water. The moistened warm air is then passed on into the duct system.
• The operating principle is exactly the same on all LOBB Power Humidifier models. Your LOBB Humidifier housing is manufactured of the highest quality non-corrosive, easily cleaned fiberglass. All component parts, except pad and pan liner are warranted for two years.
2.
INSTALLATION INSTRUCTIONS FOR MODELS WA-2700 & WA-1700 POWER HUMIDIFIERS
1. Both Models WA-2700 and WA-1700 are designed to allow mounting on either the warm air plenum of the return air plenum. Select a location on either plenum that will allow easy access for cleaning and servicing. NOTE: When a cooling coil for central air conditioning is involved, caution should be taken to insure “tapping in” where there is any restriction of air-flow to the humidifier. (See Figure 1.)
PROPER APPLICATIONS OF MODEL WA-2700 & WA-1700
3. 4.
4. Model WA-2700 & WA-1700 are designed with a reversible side cover plate for the by-pass openings. Select the side to be used and insert one of the metal collars into opening and secure by bending tabs down. Side cover plates are installed in opposite opening.
5. Insert two (2) top mounting screws and hang main body of humidifier on plenum. -- DO NOT TIGHTEN.
6. Sighting along a level line, select a location for the connecting collar. Using the collar as a template, scribe a circle. Check diameter before cutting. (7” for Model WA-2700 and 6” for Model WA-1700.) Use same cutting procedure. Insert collar and secure by bending down tabs.
WATER SUPPLY
8. Select nearest water pipe. Mount saddle valve as illustrated in drawing (See Figure 4.) Two (2) brass ferrules and two (2) ¼” compression nuts are furnished to complete the connections at the saddle valve and the unit. The installer will furnish the necessary length of ¼” water inlet tubing.
IMPORTANT: It is the responsibility of the INSTALLER to insure that the installation is made in accordance with local codes, and in a manner that does not conflict with warranties on other equipment.
5. 6.
9. Insert the rotating drum. The LOBB WA-2700 and WA-1700 Humidifiers are designed to insert or remove the drum from either top or bottom of unit.
10. A. Attach water pan on WA-2700 with stainless steel pan clips. Clips are applied with dimpled side up into molded slot and locked in position by sliding ¼” toward back of unit.
10. B. Attach water pan on WA-1700 by inserting pan so that molded lips on rear of pan lock into rear bar on case – secure by use of brass holding screw in front.
3. Center punch the four (4) holes as indicated for model being installed, and drill 1/8” holes. Using a heavy screw driver or chisel and hammer, slash starting hole in the center of cutting line on template. Insert shears and cut to line and follow outline for opening. Remove remainder of template. (See Figure 2.)
WIRING – 24 VOLT
1. All wiring must comply with local codes and ordinances. See diagrams below. (Other optional diagrams are shown in humidistat instructions.)
NOTE: Necessary low voltage wire to be provided by installer.
®
Power Humidifiers
Installation and
Operation Instructions
11. Water Level Adjustment- If necessary With pan in place, open water supply saddle valve. To adjust water level, loosen turn thumb screw and adjust float arm up or down. Move float arm up to increase water level, or move it down to lower the water level. Tighten thumb screw after adjustment. Water level should be approximately ½” below the upper edge of the pan liner.
Do Not Overtighten Thumb Screw!
Water
Inlet Line
Pan
Liner
Water
Float
Float
Arm
Thumb
Screw
FIG. A. Typical wiring
diagram for system with single speed blower motor.
FIG. B. Typical wiring diagram for systems with multi-speed blower or when power source is external to furnace system.
WA-2700
Plenum Type
WA-1700
Plenum Type
Figure 5
NOTE: Air flow switch can be located ahead of transformer when electronic air cleaner is also to be controlled.
2. Set furnace controls so that fan is running. Turn humidistat to “ON” – Humidifier should run. Set furnace controls so that fan stops – Humidifier should stop.
3. Set furnace controls and humidistat to desired condition (35% is recommended). The humidifier will operate automatically.
723 S. Route 31 • West Dundee, IL 60118
(248)623-0222
Fax (248)623-0445