Installation instructions | LK Timer Thermostat SR 310
Holiday program
It is possible to select a so-called holiday program. In the holiday program you set the number
of days for which you want a reduced temperature plus the temperature level. The program
starts and ends at midnight.
• Press button briey.
In how many days is the holiday program to start?
• To set the number of days, press and hold
button d.
• Set the number of days using the
buttons.
How long is the holiday program to be active?
• To set the number of days, press and hold
button d.
• Set the number of days using the
buttons.
What temperature do you want during the
holiday program?
• Set the desired temperature using the
buttons.
• Save using the SET button.
Display of an activated function is performed
using the symbol.
• In the display 00:14 is displayed, for instance,
i.e. the number of days remaining. The program is terminated at midnight.
Cancel the holiday program before it has
terminated
• Press and hold button for two seconds.
This cancels the program.
Reset
On a reset the thermostat returns to its factory
settings. Any data that has been changed and
saved will be deleted. Any data that has been
changed and stored will return to the factory settings. After a reset, the time must be set; see the
section: Starting the thermostat for the rst time.
If no time is set after a reset, the thermostat will
keep the temperature constant at 21 °C. The timer
will stop and wait for input.
Calibration
Note. The adjustments below should be carried
out in consultation with an installer/expert
adviser
The timer thermostat has been calibrated before
leaving the factory. If the thermostat’s location turns
out to be unfavourable, e.g. on a cold outer wall, it
may be necessary to recalibrate the thermostat.
Correction for temperature deviation
A temperature deviation can be calibrated/corrected in a range from -3 °C to +3 °C.
Example: The temperature difference between
measured and checked temperature is +2 °C.
Correct the thermostat by -2 °C.
Correction in automatic operation
• Press and hold the SET button and the
button for approximately two seconds.
• Continue to hold the SET button.
• Correct the temperature using the
buttons.
• Save the correction by releasing the SET button and pressing SET again.
Setting of regulation accuracy
Regulation accuracy can be adjusted to ±0.5 K or
±1 K. The factory setting is ±1 K.
Adjustment of accuracy during automatic operation.
• Press and hold the SET and h button for
approximately two seconds.
• Release the h button (keep holding SET).
• Change the set value using the h button.
• Release the h button and save using the SET
button.
Technical data
Control type RS Type 1 according to
EN 60730-2-9
Regulation accuracy ±0.5 K or ±1 K (selectable)
Temperature range 0 °C– +55 °C
Battery type 2 x alkaline AA 1.5 V LR 6
Change-over contact,
volt-free 2 (1) A 250 V~ min. 1 mA, 5 V DC
Safety class Class II according to EN 60730-1
surface mounted
Protection Class IP 20 according to EN 60529
LK Art no. 336 00