LK Systems S1, S1 Dti, 241 72 86, S1 EXT, 241 72 90 Assembly Instructions Manual

1 (3)
The thermostat has a green LED-indication which is switched off when the set temperature is reached. The indicator also functions as a refe­rence point for the temperature scale of the ther­mostat dial.
Temperature range for self-modulation
Self modulation 0%
Self modulation 100%
Temperature range for self-modulation , cycle time 10 min.
Installation
The following must be observed during assembly:
• Assembly height ca. 1.5 m above oor level.
• Assembly should preferably be carried out on the inner wall.
• Ensure there is sufcient air circulation.
• Avoid secondary heat from other heat sour­ces such as sunlight, lighting etc.
Electrical connection
1. Remove the thermostat dial.
2. Remove the cover via the click fastener at the top-right hand corner of the case.
3. Carry out the electrical installation in accordance with the connection diagram (See below, or on the inside of the thermo­stat lid). NB! If LK Connection Box NC or LK Connection Box 1 is used then the con­nection diagram for the specic product should be used instead.
LK Room Thermostat S1 is an electronic room thermostat with triac output adapted to LK oor heating systems. The room thermostat is used together with electrothermal actuators with nor­mally closed function (NC). LK Room Thermo­stat S1 24V NC is available in three different de­signs, S1, S1 EXT and S1 Dti.
S1: Base thermostat for regulating room tempera­ture (Article no. 241 72 86).
S1 EXT: Thermostat for regulating of room tem­perature or for e.g. regulating oor temperature via external sensors (Article no. 241 72 90).
S1 Dti: Thermostat for regulating room tempe­rature with hidden temperature settings for e.g. public environment. There is also the possibility of regulating e.g. oor temperature via external
sensors (Article 241 72 88).
Accessories
• LK Pattress S1 (Article no. 241 72 92)
• LK External Sensor S1, suitable for S1 EXT respectively. S1 Dti (Article no. 241 72 94)
Features
• Self-modulating technology via signal pulses for optimum energy effectiveness.
• Discrete and extremely thin thermostat de­sign.
• Intended for direct mounting on walls, or alternatively to electrical installation boxes.
• Connection of external temperature sensors is possible for the models S1 EXT and S1 Dti.
• Temperature set back is possible via separate clock (clock not included).
• Soundless thermostat function.
• Simple function control via LED.
Function description
For optimum energy efciency the room thermo­stat operates with so-called self-modulation tech­nology via signal pulsing to the valve actuator. Self-modulation technology adjusts the indicated oor heating output in relation to the set tempe­rature. When the room temperature reaches the set temperature the output effect is reduced to avoid overheating.
LK Room Thermostat S1, 24V NC
EN.33.C.99.1703
Assembly instructions | LK Room Thermostat S1, 24V NC
2 (3)
EN.33.C.99.1703
Assembly instructions | LK Room Thermostat S1, 24V NC
Limitation of thermostat dial installation range
The thermostat dial installation range can be limi­ted. There are two plates beneath the dial which can be moved to restrict the installation range as per the diagram below.
Connection of LK External Sensor S1
LK External Sensor S1 is intended for use to­gether with LK Room Thermostat S1 EXT or LK Room Thermostat S1 Dti for regulating oor temperature. Connect the sensor as follows:
1. Connect the external sensor to terminals 11 and 12 in the thermostat, see connection diagram.
2. Change the switch on the circuit board from INT to EXT, for external sensor.
3. If necessary the external sensor can be extended up to 50 metres. Use the same cable area or bigger than the sensor when extending. NB! Avoid routing parallel close to mains cable.
Error indication: If the LED ashes, this indicates a broken contact with the external sensor, e.g. a cable break.
The external sensor is placed as follows:
Embedding in concrete
Place the sensor in a conduit approx. 2 meters into the room before embedding in concrete. Take into consideration that the placement is at a re­presentative point for the area that is going to be adjusted. The end of the sensor is to be placed bet­ween two oor heating pipes. Seal the end of the conduit with tape or similar to prevent concrete from getting into the conduit. Try to place the con­duit as high as possible since this gives a more op­timal adjustment of the oor surface temperature. The external sensor is slipped into the conduit be­fore pouring the concrete and is connected to the room thermostat as instructed above.
Click
Opening the cover.
24V~
1
4 2
5
LK Room Thermostat S1
24V~
EXT INT
1
4 2
5 11 12
LK Room Thermostat S1 EXT and S1 Dti with possibility for connection of LK External sensor S1.
3 (3)
EN.33.C.99.1703
Assembly instructions | LK Room Thermostat S1, 24V NC
Technical data
Voltage 24 V AC (20..30 V, 50/60 Hz) NC currentless closed
Switch effect max 15 W (625 mA)
Max 5 LK Actuator 24V NC per room thermostat
Temp. range 5-35°C
Input for temp. reduction -3K
Cycle time for self-modulation 10 min
Range for self-modulation 2K
Colour, white polished RAL 9010
Protection Class III
Degree of Protection IP30
Storage temperature -20 to +70°C
Relative humidity (storage) 95% non-condensing
Working temperature 0 to +40°C
External sensor, length 4m, type NTC 47kΩ (additional)
With connected sensor, built-in temp limited to 42 °C
Energy declaration in accordance with EU 811/2013
Temperature regulator class IV
Temperature regulator’s contribution to
seasonal space heating energy efciency
2%
Measurement
LK Room Thermostat S1.
4 m
ø 7
25
35
55
ø 5
LK External Sensor S1, length 4m.
ø 60
13,9
78
3,8
78,5
LK HeatFloor 22, LK EPS 30/50/70 or LK Silencio
Mill a slot on the upper side of the board. Place a conduit in the slot, end the conduit right between two heat distribution plates. Take into conside­ration that the placement is at a representative point for the area that is going to be adjusted. The external sensor is slipped into the conduit befo­re laying the oor and is connected to the room thermostat as instructed above.
Floor heating in secondary spaced boarding
Place a conduit right between two heat distribu­tion plates, attach the conduit on the edge of the secondary spaced boarding using a clip for con­duits. Take into consideration that the placement is at a representative point for the area that is going to be adjusted. The external sensor is slip­ped into the conduit before laying the oor and is connected to the room thermostat as instructed above.
LK EPS 16
Place a conduit along the long sides of the oor heating installation facing the nearest short end. Saw an approx. 2 meters long slot in the EPS­board and place the conduit in the slot. Take into consideration that the placement is at a re­presentative point for the area that is going to be adjusted. The external sensor is slipped into the conduit before laying the oor and is connected to the room thermostat as instructed above.
LK Clip Rail 8/LK Clip Rail 12
Place a conduit along the long sides of the oor heating installation facing the nearest short end. Place the conduit at the short end between two heating pipes and end it approx. 2 meters in. Seal the end of the conduit with tape or similar to pre­vent concrete from getting into the conduit. The external sensor is slipped into the conduit befo­re pouring the concrete and is connected to the room thermostat as instructed above.
LK Systems AB, Box 66, 161 26 Bromma, Sweden | www.lksystems.se