Livart L-2O92, L-2093C Operating Lnstructions

LIWT
Operating
lnstructions
ULTRASONIC
HUMIDIFIER
WARM & COOI
MIST
Thank
you
for choosing
the LIVART
Humidifier.
Please read
these
instructions
before using
the LIVART
Cool
Mist Ultrasonic
Humidifier and
keep them in a safe
place
for future
reference.
lf
you
pass
the
humidifier on
to anyone
else,
you
should
also
pass
on
the
instructions.
Remove all
packaging
before
using the
product,
but
keep
the
packaging
until
you
are
satisfied
that the
product
is operating correctly.
1.
Read the operating
instructions
carefully
before
using the humidifier
and
keep
them for later
reference.
2.
connect the unit
only to alternating
curent
with voltage
according
to
the
rating
label.
3. Only
use the humidifier
indoors.
lf
used for
a
purpose
it is not intended
it could
cause
serious danger
to
health
and life.
4.
Children cannot recognize
the
hazards
associated
with
the usage
of
electrical
appliances. For
this
reason,
always
supervise children when
they
are near
the humidifier.
5.
Person
who
are not familiar
with
the
operating
instructions, as
well
as
children
and
person
under the
influence
of medication,
alcohol,
or
drugs are
not
permitted
to operate
the
appliance,
or
are only
permitted
to
operate it
under
supervision.
6. Never
use the
appliance if
there
is
any damage
to the
appliance or
cable,
after
malfunction,
after
the appliance
has
been dropped or
damaged
in any
other
way.
7.
Only operate
the humidifier
when it
is completely
assembled.
8.
Repairs
of electrical
appliances
are
only to
be
made by
qualified
service
engineers.
lmproper
repair
work
can
cause
considerable
danger
to the
user.
9. Disconnect
the appliance
from
the mains
power
before
filling/emptying
the
water
tank,
before
cleaning/maintenance,iassembling/dismanfl
ing
of
individual
parts
and
before
moving
it.
10. Place
the humidifier
on
a dry,
level
surface.
11.
Do not
pour
water into
the ventilator
of the humidifier.
12. Do
not
put
any additives
in
the waler.
(e.9.
fragrances,
essential
oils, water
fresheners,
etc.)
13. Do not
submerse
the
main body
in water
or
other liquids.
N The
using of
tap
water
can
be
main cause
of breakage of
transducer
due
to,,
compounds
of calcium in
the
water. So
please
use a
scale
filter
atter
purchasing
it
additionally.
(lF
you
use
the
clean water, never
happen
scalec.r
transducer
and
vaporized
cleaning
vapor.)
Generol informqtion
A comfortable
atmosphere
indoors is reached
with a
relative
humidifier
level
between 40%
and
60%.
Water tank
Water-level
sensor
Reservoir
Power cord
Main body
3
A _ _ _
Finding the ideal location
lor
your
LIVART humidifier.
a
GAUTION
:ffuxi?!"li::lx;lllr;Slxlil;rm:ai:x'i:3,:':1x,f,:i:fi:ai'oorwirhf'|oorheatins'
I
Make
sure
that no foreign
objects
are in the water tank.
N-,
1
(D
plD
d6P
Fill the
tank
with clean,
cold water
from
the
tap
or
purifier.
(no
hotter
than
40"C).
.
lfyou
use clean
water,
you
can use the
appliance with
cleaning state
for
a long
time
and
lor
sanitary
reasons,
good
for
your
health.
Close the cap of the
water
tank
properly.
.
Wait until the reservoir in the
appliance is filled with
water.
rD
.\.-/
lnsert
the
plug
into
the socket.
.
lnsert
the
plug
into the
socket and switch on the appliance
using the onioff switch.
4
.
L-2092
r On-otf switch.
I
.
Turning the
right switch clockwise o
POWER
o
EMPTY
oFF6fr9x
,:'dH;":
iv.j
POWER
Regulation
of
vapor output.
.
Regulates the
vapor output
lrom low to high.
o
POWER
o
EMPTY
OFFAON
;'ffi;,
ltd,
POWER
.
[-2093C
t
On-Off
switch
and operation
with
WARM/COOL.
.
Turning the
POWER switch clockwise.
.
On selecting
WARM
is
preheated
to
60'C
before entering
the resevoir So
the vapor
will have the
pleasant
temperature
of 40"C.
This
provides
the advantage
that the
room
temperature
will not
fall, and additionally the
water
can be
kept essentially
cleaner.
(bacteria
are
killed.)
Regulation of
vapor output.
.
Regulates the
vapor output
from low to high
MED
@
MIST
o
POWER
o
EMPTY
cooL
oFFrtA\wARM
.'A*xL'.
,sil,
POWER
cooL
oFFZAWARM
:'5gi
is#j
POWER
MED
o
POWER
o
EMPTY
MIST
5
A
Caution
)
Switch off
the
appliance and unplug it from the socket before cleaning it.
)
Clean
the water tank
and the reservoir regularly.
\t->
6
Attention
.
lf
possible,
use clean water.
.
Make
sure that
no water
gets
into
the
lower
part
of the
main body.
.
Clean
the inner
parts
with
a soft cloth. Do
not use
any
solvents or aggressive
cleaning
agents to clean
the appliance.
.
Only
use the brush to clean the transducer,
this should be done
once a week.
ffie
I
2
?
Cleon
the humidifier
os
descriH eorlier ond
dry
it
thoroughly.
Avoid high temperolures.
Preferobly
store
the
opplionce
in ih
originol
box.
Problem Possible
couse Whot
to
do
,,Hitllidilhr,&es
:n0tiOp.$-t$e
.
Power cable not
plugged
in.
.
Humidifier not
switched on.
.
No water
in
the tank.
(Empty-light
flashing)
*
Plug in
power
cable.
*-
Push
pcrwerbutton.
:
Fill tank with water.
.
Water temperature is too low.
:
Set vapor output to maximum about
10 min. ln that
case, the
humidifier
will
work
properly
again.
Ito.vryor.aqlpUt
.fiQricl-e-aning
mtl
toea,
.
Mineraldeposits
on transducer.
*-
Clean
transducer
again.
L!30,* Li2093C""
&iirii$rnK.g!
120V
AC
/ 60Hz
40w 140W
(Cool
mist : 40W)
2.5
gal.l
day 3.5gal./day(Cool
mist:2.5)
1.7
gal.
14.8
x
7.8
x
15.2
in.
7.0lb.av.
PIease
contact
your
dealer
il,
despile
strict
quality
control,
your
humidifier becomes
defective.
This
product
is
warranted for 3 months and
you
must
present
the
receipt
when making a claim
under the
warranty.
-
LG-LIVART 2110
S. TUBEWAY AVE.
COMMERCE, CA 9OO4()
-
Toll
Free :1-877-260-4949