VCL-14 Series
Applications
Designed for automatic collection and removal of
•
condensate from air conditioning, refrigeration and
dehumidification equipment when gravity drainage
is not possible or practical. Also suitable for high
efficiency oil and gas-fired condensing furnace and
condensing boiler equipment.
Features
1 gallon collection tank
•
Vertical centrifugal pump design
•
Automatic start and stop operation
•
Includes float (solid polymer) activated switch for
•
automatic high level water detection
(safety overflow switch)
Safety overflow switch: dual function NO and NC
•
operation (set to NO from factory for equipment
shut down connection)
Safety overflow switch includes two 5” switch
•
lead wires
¼” NPT x 3/8” barbed discharge adapter (for use
•
with 3/8” I.D. vinyl tubing)*
*Optional ¼” NPT check valve adapter for 3/8”
•
vinyl tubing sold separately
(Part Number 599065)
*Optional ¼” NPT check valve for 3/8” copper
•
tube sold separately (Part Number 599063)
Two 1-1/8” diameter inlet openings
•
Thermally protected, fan cooled motor
•
Maximum water temperature: 120 ºF
•
6 ft, 3-conductor cable with grounded 3-prong plug
•
Wastewater • Water Systems • HVAC • Industrial • Engineered Products
Construction
Motor — 1/50 hp
•
Discharge — 3/8" O.D. barbed
•
Pump housing — ABS
•
Switch housing — ABS
•
Tank — ABS
•
Tank cover — Galvanized steel
•
Motor shaft — Stainless steel
•
Impeller — Polypropylene
•
Discharge adapter — Acetal
•

Engineering Data
"
"
1.40"
"
"
3.00"
"
"
"
Specications
Item
No.
553101 VCL-14ULS 3/8" OD Barbed 1/50 115 60 1.0 78 200 185 170 125 14 6.1 6 6.80
Model
No.
Discharge
Size HP Volts Hertz Amps Watts
Performance (GPH@Head) Shutoff
Cord
Length (ft)
Weight
(lbs)1' 3' 5' 9' Ft PSI
8.88"
Replacement Parts
Item Part Number
Tank 153502
Cover, volute 153110
Impeller 153132
Adapter, 3/8" 153300
Seal ring 924038
Switch, pump 950337
Switch, safety 950333
P.O. Box 12010
Oklahoma City, OK 73157-2010
Phone: 1.800.701.7894
Fax: 1.800.678.7867
www.LittleGiantPump.com
Performance Data
Flow - Liters/Hour
0 189 378 567 756 945
20
15
10
Head - Feet
5
0
0 50 100 150 200 250
Flow - Gallons/Hour
6
5
4
3
2
1
0
Form 995126 – 08/12
Head - Meters