Little Giant 1-T User Manual

In
dust
a
ri
#1 Series
l
Features
Oil-filled motor
7.4' maximum lift
70 watts
1/4" MNPT discharge
Thermal overload protection
(except 501003)
For submersible use only
Construction
MOTOR – 1/150 HP Oil Filled.
INTERMITTENT LIQUID TEMP.
UP TO — 120° F.
INTAKE – N/A.
DISCHARGE – 1/4" MNPT.
HOUSING – Epoxy coated cast aluminum
COVER – Epoxy coated cast aluminum
VOLUTE – Polypropylene
IMPELLER – Polypropylene
SHAFT SEAL – Nitrile
SCREEN – Polyethylene
Wastewater • Water Systems • HVAC • Industrial • Engineered Products
Dimensional Outline
Specifi cations
Model
No.
1 501003 1/4" MNPT UL 1/150 115 60 1.1 70 205 168 120 7.4 3.2 6 3.5
1 501500 1/4" MNPT 1/150 127 60 1.1 70 205 168 120 7.4 3.2 6 3.5
1-T 501086 1/4" MNPT UL/CSA 1/150 115 60 1.1 70 205 168 120 7.4 3.2 10 3.7
1-Y 501016 1/4" MNPT UR 1/150 230 50/60 .6/.4 70 205 168 120 7.4 3.2 12* 3.8
* NO PLUG
Item
No.
Discharge
Size
Listing HP Volts Hertz Amps Watts
Performance (GPM@Head) Shutoff
1' 3' 5' Ft. P.S.I.
Cord
Length (ft.)
Weight
(lbs.)
Replacement Parts Performance Data
Volute 101375
Impeller 101441
Screen 101376
Elbow 943470