Little Giant submersible 14S and 16S series sewage ejector
pumps and 14EH/16EH series effluent pumps are recommended
for use in basins or lift stations and are suitable for pumping
sewage, effluent, wastewater, and other non-explosive, noncorrosive liquids.
Little Giant offers a complete line of float switches and liquid level
control systems for automatic operation, along with a complete
line of alarms, basins, covers, and check valves.
EN
ENGLISH
This instruction sheet provides you with the information required
to safely own and operate your product. Retain these instructions
for future reference.
The product you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. This product has been carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your item(s) carefully to ensure that no damage
occurred during shipment. If damage has occurred, please
contact the place of purchase. They will assist you in replacement
or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE
YOUR PRODUCT. KNOW THE PRODUCT’S APPLICATION,
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH THESE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
SAFETY GUIDELINES
WARNING
READ ALL INSTRUCTIONS AND SAFETY GUIDELINES
THOROUGHLY. FAILURE TO FOLLOW THE GUIDELINES AND
THE INSTRUCTIONS COULD RESULT IN SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE.
WARNING: RISK OF ELECTRIC SHOCK. This pump is supplied
with a grounding conductor and/or grounding type attachment
plug. To reduce the risk of electric shock, connect it only to a
properly grounded, grounding-type receptacle.
If this pump is equipped with a 3-prong electrical plug, the third
prong grounds the pump to prevent possible electrical shock
hazard. Do not remove the third prong from the plug. A separate
branch circuit is recommended. Do not use an extension cord.
When the pump is in a basin, sump, lift station, etc., do not touch
the motor, pipes, or water until the pump is unplugged or shut off.
If your installation has water or moisture present, do not touch the
wet area until all power has been turned off. If the shut-off box is
not accessible, call the electric company to shut off service to the
Figure 1 - Dimensions
MODELLISTING HPVOLTS
14EH-CIMUL1/211512.5/1450NRNR604020
14EH-CIMUL1/2208-2405.7/1275NRNR604020
14S-CIMUL1/211511.6/110013010035
14S-CIMUL1/2208-2404.6/110013010035
16EH-CIMUL12309.0/2200NRNRNR9070503081'35.12082
16S-CIMUL123011.0/190018016010040
16S-CIMUL1200-208 11.0/200018016010040
NR: Not recommended. Operation at these heads or below will result in motor overload, reduced pump life, and/or motor failure/damage.
AMPS/
WATTS
GALLONS PER MINUTE @ FEET OF HEAD
----
----
--------
--------
------
------
50'21.62074
50'21.62074
25'10.82080
25'10.82080
35'15.12088
35'15.12088
POWER
CORD
(ft.)
WEIGHT
(lbs.)5'10'20'30'40'50'60'SHUT-OFF P.S.I.
1
Page 2
house, or call your local fire department for instructions. Failure to
follow this warning can result in fatal electrical shock.
Do not modify the power cord except to shorten it to fit into a
control panel. Any splice between the pump and the control panel
must be made within a junction box and mounted outside of the
basin, and comply with the National Electrical Code. Do not use
the power cord for lifting the pump.
The pump motor is equipped with an automatic-resetting, thermal
protector and may restart unexpectedly. Protector-tripping is an
indication of motor overloading as a result of operating the pump
at low heads (low discharge restriction), excessively high or low
voltage, inadequate wiring, incorrect motor connections, or a
defective motor or pump.
Do not use to pump flammable or explosive fluids such as
gasoline, fuel oil, kerosene, etc. Failure to follow this warning can
result in personal injury and/or property damage.
During normal operation the pump is immersed in water. Also,
during rain storms, water may be present in the surrounding area
of the pump. Use caution to prevent bodily injury when working
near the pump:
Remove the plug from the receptacle before touching, servicing,
or repairing the pump.
To minimize possible fatal electrical shock hazard, use extreme
care when changing fuses. Do not stand in water while changing
fuses or insert your fingers into the fuse socket.
Do not operate the pump in a dry basin. This will cause the
pump to become extremely hot, causing burns if touched and/or
damage to the pump.
Do not oil the motor. The pump housing is sealed. A high grade
dielectric oil devoid of water has been put into the motor housing
at the factory. Use of other oil could cause serious electric shock
and/or permanent damage to the pump.
Do not install the pump in locations classified as hazardous in
accordance with the National Electrical Code, ANSI/NFPA 70.
In any installation where property damage and/or personal injury
might result from inoperative or leaking pump due to power
outages, discharge line blockage, or any other reason, use a
backup system(s) and/or alarm.
SPECIFICATIONS
DISCHARGE: 14EH and 16EH – 2”, 14S – 2” or 3”, 16S – 3”
HANDLING CAPABILITIES: EH Series – 3/4” spherical solids,
S Series – 2” spherical solids
HOUSING: Cast iron
VOLUTE: Cast iron
IMPELLER: Non-clog, cast iron with pressure relief vanes
MOTOR: PSC, 3450 RPM (EH Series), 1625 RPM (S Series), with
automatic overload protection
HARDWARE: 300-series stainless steel
BEARING: Ball
SHAFT SEAL: Mechanical, spring-loaded, rotating carbon with
Nitrile boot and stationary ceramic seat, with secondary Nitrile
exclusion seal
COOLING: The motor housing contains oil to cool the motor
and to lubricate the bearings and seals. For the best cooling and
longest motor life, however, the level of the liquid being pumped
should be above the top of the motor housing.
INSTALLATION
WARNING
For automatic operation, plug or wire the pump into a float switch
or liquid level controller. Installation instructions are included with
all Little Giant switches and controllers and should be referred to
for installation.
The pump will run continuously when plugged directly into an
electrical outlet. Take care to prevent the pump from running in
a dry sump.
Install the pump in a suitable, gas-tight basin that is at least 18”
in diameter and 30” deep, and vented in accordance with local
plumbing codes.
Place the pump on a hard, level surface. Never place the pump
directly onto clay, earth, or gravel surfaces.
The pump can be installed with ABS, PVC, polyethylene, or
galvanized steel pipe. Proper adapters are required to connect
plastic pipe to the pump.
To facilitate pump removal (if necessary), install a union just
above the cover.
Use a check valve in the discharge line to prevent backflow of
liquid into the basin. This should be a free-flow valve that will easily
pass solids.
CAUTION: For best performance of check valves, when handling
solids install the valve horizontally or at an angle of no more than
45°. Do not install the valve vertically, as solids may settle in the
valve and prevent opening on start-up.
A gate valve should follow the check valve to allow periodic
cleaning of the check valve or removal of the pump.
The remainder of the discharge line should be as short as
possible with a minimum of turns to minimize friction head loss.
Do not restrict the discharge to sizes below 2”.
Sewage and effluent applications require a separate sump
vent. A connection is provided on top of the sump or cover.
This connection must be piped to the existing building vent or
extended outside with its own standpipe.
WIRING
WARNING
Check local electrical and building codes before installation. The
installation must be in accordance with their regulations as well as
the most recent National Electrical Code (NEC).
To conform to the National Electrical Code, all pumps must be
wired with 14 AWG or larger wire. For runs to 250 feet, 14 AWG
wire is sufficient. For longer runs, consult a qualified electrician
or the factory.
Connect or wire the pump to its own circuit, with no other outlets
or equipment in the circuit line. Fuses and circuit breaker should
be of ample capacity in the electrical circuit. See Table 1.
FUSE OR CIRCUIT
H.P.VOLTAGE
½, 111520
½, 123015
TABLE 1
BREAKER AMPS
2
Page 3
MAINTENANCE AND SERVICING
WARNING
WARNING: Before working on the pump or switch, unplug the
pump power cord, in addition to removing the fuse or shutting off
the circuit breaker.
If the pump does not operate properly, consult the Troubleshooting
table. If the trouble still cannot be found, consult your pump dealer
or take the pump to a Little Giant authorized service center.
CAUTION: DO NOT remove the socket head cap screws (item
#3, Figure 3). The motor section of your pump is permanently
lubricated with dielectric oil and is sealed at the factory. Removal
of these screws by anyone other than an authorized Little Giant
service center will break the seal and void the warranty.
1. Remove the 4 screws (item #18, Figure 3) that hold the
volute to the motor housing, then separate the volute from the
housing
2. Clean the impeller and volute passage.
3. Be sure impeller turns freely.
4. Attach the volute to the housing and secure it with the 4
screws.
Gate valve
Check valve
Discharge
Intake
Caulking hub
Air bleed hole
Union
Switch plug
(optional)
Pump plug
Vent
Pump on level
Pump off level
Float switch
(optional)
FIGURE 2 - TYPICAL INSTALLATION
3
Page 4
Figure 3
4
Page 5
MODEL/CATALOG NO.
ITEM
NO.
10903722SCREW, 7/16-14 x 1-1/4”222222222
11921104LOCK WASHER, 7/16”222222222
12114101FLANGE GASKET111111111
13114038VOLUTE, 14EH/16EH11
13114043VOLUTE, 14S/16S111111
14920004JAM NUT, 1/2” x 20111111111
15114054IMPELLER, 14EH11
15114044IMPELLER, 14S
15114056IMPELLER, 16EH
15114052IMPELLER, 16S
16926016V-SEAL, NITRILE111111111
17928033SEAL RING, 7.484” I.D.111111111
18903724SCREW, 5/16-18 x 1-1/4”444444444
19951972LEAD WIRE ASSY., RED111111111
20951971LEAD WIRE ASSY., BLACK111111111
21928034SEAL RING, 5.359” I.D.111111111
22951843
22951844
22951842
22951840
23921105LOCK WASHER, 5/16”444444444
PART
NO.DESCRIPTION
1114100WIRE HANDLE111111111
2114051COVER, HOUSING111111111
3903723SCREW, 1/4-20 x 3/4”444444444
4921103LOCK WASHER, 1/4”444444444
5902437SCREW, #8-32 x 1/4”333333333
6921059LOCK WASHER, #8333333333
950500/
7
950503
950501/
950503
7
950504/
950505
8950502BOOT, INSULATING111111111
9114004DISCH. FLANGE, 2” FNPT1111--1
9114009DISCH. FLANGE, 3” FNPT
CAPACITOR, 20mfd,
1.75” DIA/CLIP, 1.75” DIA.
CAPACITOR, 30mfd,
1.75” DIA/CLIP, 1.75” DIA.
or
———————————
CAPACITOR, 30mfd,
2.00” DIA/CLIP, 2.00” DIA.
14EH-CIM
514220
14EH-CIM
514221
14S-CIM
514320
----
11
111--111
------
--------
------
14S-CIM
514321
14S-CIM
514420
1
16EH-CIM
514520
16S-CIM
1
------
------
111
--
1
------
514620
16S-CIM
514625
16S-CIM
--------------
111
1
--
1
--
--------
1
1
--
1
--------
111
----------
------
111
--
1
WIRING HARNESS,
115V W/PLUG
WIRING HARNESS,
STRIPPED
WIRING HARNESS,
208-240V W/PLUG
WIRING HARNESS,
230V, 40’, 16/3
----
----------
------------
1
----------
--
----------------
514630
Table 2 - Replacement Parts
5
Page 6
PROBLEMPROBABLE CAUSESCORRECTIVE ACTION
Pump does not turn on.
NOTE: Before troubleshooting automatic
control, check to see that pump operates
on manual control. To do this, unplug from
in-line float switch plug. Plug pump power
cord into wall outlet. If pump works, proceed
to check switch; if not, fault is in pump or
power supply.
Pump will not shut off.
Pump runs but does not discharge liquid.
Pump does not deliver rated capacity.
Pump cycles continually.
TROUBLESHOOTING
Pump not plugged in.Plug in pump.
Circuit breaker shutoff or fuse removed.Turn on circuit breaker or replace fuse.
Accumulation of trash on mercury float switch.Clean float.
Mercury float switch obscruction.Check float path and provide clearance.
Defective switch.
Defective motor.Have pump serviced.
Mercury switch float obstruction.Check float path and provide clearance.
Loose connection in level control wiring.Check control wiring.
Check valve installed backwards.
Check valve stuck or plugged.Remove check valve and inspect for proper operation.
Lift too high for pump.Check rating table.
Inlet to impeller plugged.Pull pump and clean.
Pump is air locked.(See corrective action above.)
Lift too high for pump.Check rated pump performance.
Low voltage, speed too slow.
Impeller or discharge pipe is clogged.
Impeller wear due to abrasives.Replace worn impeller.
No check valve in long discharge pipe, allowing liquid
to drain back into basin.
Check valve leaking.Inspect check valve for correct operation.
Basin too small for inflow.Install larger basin.
Disconnect switch, check with ohmmeter:
Open=infinite resistance, closed=zero.
Shut power off for approximately 1 minute, then
restart. Repeat several times to clear air from pump.
If system includes a check valve, a 3/16” hole should
be drilled in discharge pipe approximately 2” above
discharge connections.
Disconnect switch, check with ohmmeter:
Open=infinite resistance, closed=zero.
Check flow indicating arrow on check valve body to
insure it is installed properly.
Check for proper supply voltage to make certain it
corresponds to nameplate voltage.
Pull pump and clean. Check pipe for scale or
corrosion.
Install a check valve in discharge line.
6
Page 7
LIMITED WARRANTY
SUMP, EFFLUENT & RESIDENTIAL SEWAGE
INTRODUCTION
Little Giant #8E, #9E, #1OE, #14EH, and #16EH Series
Submersible Effluent Pumps are recommended for use in sumps,
basins or lift stations and suitable for pumping basement drainage
water, effluent, wastewater and other non-explosive, non-corrosive,
non-abrasive liquids not above 140°F with up to 3/4" spherical
solids handling ability (NOT TO BE USED FOR SEWAGE WATER
EXCEPT TO PUMP SEPTIC TANK EFFLUENT)
Little Giant #9S, #10S, #14S and #16S Series Submersible
Sewage Ejector Pumps are recommended for use in sumps,
basins or lift stations and suitable for pumping sewage, effluent,
wastewater and other non-explosive, non-corrosive, non-abrasive
liquids not above 140°F with up to 2" spherical solids handling
ability.
Each of the above noted Little Giant products is guaranteed to be in
perfect condition when it leaves our factory. During the time periods
and subject to the conditions hereinafter set forth, LITTLE GIANT
PUMP COMPANY, subsidiary of Franklin Electric Company, Inc.,
will repair or replace to the original user or consumer any portion
of your new LITTLE GIANT product which proves defective due to
materials or workmanship of LITTLE GIANT. Contact your nearest
Authorized Little Giant Dealer for warranty service. At all times
LITTLE GIANT shall have and possess the sole right and option to
determine whether to repair or replace defective equipment, parts,
or components. Damage due to lightning or conditions beyond the
control of LITTLE GIANT is NOT COVERED BY THIS WARRANTY.
WARRANTY PERIOD
PUMPS: 24 months from date of purchase or 30 months from
date of manufacture, whichever occurs first.
LABOR, ETC. COSTS: LITTLE GIANT shall IN NO EVENT be
responsible or liable for the cost of field labor or other charges
incurred by any customer in removing and/or affixing any LITTLE
GIANT product, part or component thereof.
THIS WARRANTY WILL NOT APPLY:
1. to defects or malfunctions resulting from failure to properly
install, operate, or maintain the unit in accordance with printed
instructions provided
2. to failures resulting from abuse, accident or negligence
3. to normal maintenance services and the parts used in
connection with such service
4. to units which are not installed in accordance with applicable
local codes, ordinances and good trade practices
5. unit is used for purposes other than for what it was designed
and manufactured
6. if pump exposed to but not limited to the following: sand,
gravel, cement, grease, plaster, mud, tar, hydrocarbons, or
hydrocarbon derivatives (oil, gasoline, solvents, etc.) or
other abrasive or corrosive substances.
7. if pump has been used for continuous pumping of suitable
liquids above 140°F
8. if power cord has been cut or spliced
9. if pump has been dismantled by customer (Dealer only can
dismantle pump for field service.)
RETURN OR REPLACED COMPONENTS: Any item to be
replaced under the Warranty must be returned to LITTLE GIANT
at Oklahoma City, OK or such other place as LITTLE GIANT may
designate, freight prepaid.
PRODUCT IMPROVEMENTS: LITTLE GIANT reserves the right
to change or improve its products or any portions thereof without
being obligated to provide such a change or improvement for
units sold and/or shipped prior to such change or improvement.
DISCLAIMER: Any oral statements about the product made by the
seller, the manufacturer, the representatives or any other parties do
not constitute warranties, shall not be relied upon by the user, and
are not part of the contract for sale. Seller’s and manufacturer’s onIy
obligation, and buyer’s only remedy, shall be the replacement and/
or repair by the manufacturer of the product as described above.
Neither seller nor the manufacturer shall be liable for any injury,
loss or damage, direct, incidental or consequential (including, but
not limited to, incidental or consequential damages for lost profits,
lost sales, injury to person or property, or any other incidental or
consequentiaI loss), arising out of the use or the inability to use
the product, and the user agrees that no other remedy shall be
available to it. Before using, the user shalI determine the suitability
of the product for his intended use, and user assumes all risk
and liability whatsoever in connection therewith. The warranty
and remedy described in this limited warranty is an EXCLUSIVE
warranty and remedy and is IN LIEU OF any other warranty or
remedy, expressed or implied, which other warranties and
remedies are hereby expressly EXCLUDED, including but
not limited to any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some states do
not allow the exclusive or Imitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to
you. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state.
In the absence of other suitable proof of the purchase date,
the effective date of this warranty will be based upon the date of
manufacture plus 24 months. Direct all notices, etc., to: Service
Department, LITTLE GIANT PUMP COMPANY, 301 North MacArthur
Blvd., Oklahoma City, OK 73127-6616.
DETERMINATION OF UNIT DATE OF MANUFACTURE: (9-87)
month and year stamped on pump and/or serial number on pump
nameplate coded to indicate year of manufacture.
7
Page 8
For parts or repair, please contact . . . . . . . . . . . . . . . . . . . .1-888-572-9933