The new VL Series device provides reliable, noncycling
protection against overcharging and short circuits events
for rechargeable battery cells where resettable protection
is desired.
Features
• RoHS compliant and
lead–free
• Weldable Nickel terminals
• Slim, low profile design
Agency Approvals
AGENCYAGENCY FILE NUMBER
Applications
E183209
• Rechargeable battery cell
R50119583
protection
Electrical Characteristics
Maximum Time
d
Current
(A)
To Trip
Time
(Sec.)
Part Number
I
hold
(A)
I
(A)
V
trip
(Vdc)
max
I
(A)
max
P
max.
(W)
12VL1701.704.10121001.48.505.000.0180.0320.064
12VL175L1.754.20121001.48.755.000.0170.0310.062
12VL175XL1.754.20121001.48.755.000.0170.0310.062
12VL2302.305.00121001.510.005.000.0120.0180.036
I
= Hold current: maximum current device will pass without tripping in 20°C still air.
hold
= Trip current: minimum current at which the device will trip in 20°C still air.
I
trip
= Maximum voltage device can withstand without damage at rated current (I max)
V
max
= Maximum fault current device can withstand without damage at rated voltage (V
I
max
= Power dissipated from device when in the tripped state at 20°C still air.
P
d
= Minimum resistance of device in initial (un-soldered) state.
R
min
)
max
= Typical resistance of device in initial (un-soldered) state.
R
typ
= Maximum resistance of device at 20°C measured one hour after tripping or reflow
R
1max
soldering of 260°C for 20 sec.
Caution: Operation beyond the specified rating may result in damage and possible arcing
and flame.
Specifications are subject to change without notice.
Please refer to www.littelfuse.com/series/VL.html for current information.
125
Revised: June 4, 2010
VL Series
Page 2
POLYFUSE® Resettable PTCs
Axial Lead Battery Strap Type > VL Series
Temperature Rerating
Ambient Operation Temperature
-40°C-20°C0°C25°C40°C50°C60°C70°C
Part NumberHold Current (A)
12VL1703.52.92.41.701.21.00.70.3
12VL175L3.52.92.41.751.31.00.80.3
12VL175XL3.52.92.41.751.31.00.80.3
12VL2305.0 4.2 3.42.301.71.30.9 0.4
Average Time Current Curves
1.70 A
2.30 A
1.75 A
10
1
Time in Seconds
0.1
0.01
1.0
101001000
Current in Amperes
VL
Temperature Rerating Curve
220%
190%
170%
150%
130%
110%
90%
70%
50%
Percentage of Rated Current
30%
10%
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80
Temperature (°C)
The average time current curves and Temperature Rerating curve performance is affected
by a number or variables, and these curves provided as guidance only. Customer must
verify the performance in their application.