POWR-GARD
®
Fuseblocks
powr-bloks™
Distribution/Splicer Blocks and Covers
Description
POWR- BLOKSTM power distribution blocks offer a safe,
convenient way of splicing cables, providing a fixed junction
tap- off point or splitting primary power into secondary
circuits. Lx2xxx-DIN series offers integral DIN-Rail mount
and an optional hinged safety cover.
Optional power distribution block covers provide protection
against accidental shorting between poles caused by
loose wires, tools, or other conductive material. They also
protect personnel from accidentally contacting energized
connectors. To order protective covers, match the number
of poles for the block to the cover.
Hinged Plastic Covers
Catalog/system
number
LCH132-1 0LCH1321Z LD2xxx-1DIN / LS2xxx-1DIN 1
LCH132-2 0LCH1322Z LD2xxx-2DIN / LS2xxx-2DIN 2
LCH132-3 0LCH1323Z LD2xxx-3DIN / LS2xxx-3DIN 3
Note: Optional hinged covers snap on to blocks.
Distribution/spliCer bloCk no.
For use with
poles
Applications
Typical applications include heating, air conditioning and
refrigeration systems, el e va tor systems, material handling
equipment, control panels, motor controls, switchgear, and
anywhere power needs to be distributed to more than one load.
Connectors
Box lug connectors are designed for use with a single, solid
or class B or C stranded conductor. Use of more than one
con ductor per connector opening or use of extra-flexible,
fine-stranded conductors, such as welding cable, voids the
UL Listing and may cause overheating. Manufacturers of cable
ter minations can furnish crimp-on sleeves for fine stranded
conductors which permit these conductors to be used
with box lugs.
Ampere Ratings
The ampere rating per pole for power distribution blocks is
based on the line ampacity of 75°C insulated conductors per
®
NEC
Table 310.16. If 60°C insulated conductors are used, load
must not exceed the ampacity of 60°C conductors. Use of
conductors rated in excess of 75°C is permitted (for example
90°C), however, load must not exceed the ampacity of 75°C
conductors.
Specifications
Voltage Rating: 600 V
Current Rating: Based on NEC Table 310.16, using 75°C copper wire
Material: Phenolic rated at 150°C and Thermoplastic
rated at 125°C (LD1400 and LS1300 series only)
Connector: Standard: Highly con duc tive aluminum, tin plated
Copper: Highly conductive copper, tin plated
Flammability Rating: UL94 V-0
Approvals: UL Recognized (File No. E171395)
CSA Certified (File No. LR700111)
Clear Plastic Covers
Catalog/system
number
LPBC0-2 LPBC02 LD0xxx-2 / LS0xxx-2 2
LPBC0-3 LPBC03 LD0xxx-3 / LS0xxx-3 3
LPBC2-1 LPBC21 LD2xxx-1 / LS2xxx-1 1
LPBC2-2 LPBC22 LD2xxx-2 / LS2xxx-2 2
LPBC2-3 LPBC23 LD2xxx-3 / LS2xxx-3 3
LPBC3-1 LPBC31 LD3xxx-1 / LS3xxx-1 1
LPBC3-2 LPBC32 LD3xxx-2 / LS3xxx-2 2
LPBC3-3 LPBC33 LD3xxx-3 / LS3xxx-3 3
LPBC4-1 LPBC41 LD4xxx-1 / LS4xxx-1 1
LPBC4-2 LPBC42 LD4xxx-2 / LS4xxx-2 2
LPBC4-3 LPBC43 LD4xxx-3 / LS4xxx-3 3
LPBC5-1 LPBC51 LD5xxx-1 / LS5xxx-1 1
LPBC5-2 LPBC52 LD5xxx-2 / LS5xxx-2 2
LPBC5-3 LPBC53 LD5xxx-3 / LS5xxx-3 3
Note: For installation of optional clear plastic covers, use the screws provided with each
cove r.
Distribution/spliCer bloCk no.
For use with
poles
Ordering Information
Distribution Block
Example Part No.
Note: Aluminum blocks can use copper or aluminum wire;
copper blocks can only use copper wire.
Splicer Block
Example Part No.
Web Resources
For more information, visit: www.littelfuse.com/powr-bloks
1
© JUNE 2011 Littelfuse POWR-GARD Productswww.littelfuse.com
POWR-GARD
®
Fuseblocks
Distribution/spliCer bloCks anD Covers
Distribution Block Selection Guide
ConneCtor
ConFiguration
material line loaD
AL
AL
AL
AL
AL
CU
AL
AL
AL
CU
CU
AL
AL
AL
AL
AL
AL
AL=Aluminum, CU= Copper
amp
rating
per
pole
115 1 #2 - #14 1 #10 - #18 4 2 LD1400-1 0LD14001Z
115 2 #2 - #14 1 #10 - #18 4 2 LD1400-2 0LD14002Z
115 3 #2 - #14 1 #10 - #18 4 2 LD1400-3 0LD14003Z
115 4 #2 - #14 1 #10 - #18 4 2 LD1400-4 0LD14004Z
175 2 2⁄0 - #14 1 #4 - #14 6 1 LD0401-2 0LD04012Z
175 3 2⁄0 - #14 1 #4 - #14 6 1 LD0401-3 0LD04013Z
175 2 2⁄0 - #14 1 #4 - #14 4 1 LD0402-2 0LD04022Z
175 3 2⁄0 - #14 1 #4 - #14 4 1 LD0402-3 0LD04023Z
310 2 350mcm - #6 1 #4 - #14 6 1 LD0404-2 0LD04042Z
310 3 350mcm - #6 1 #4 - #14 6 1 LD0404-3 0LD04043Z
175 1 2⁄0 - #14 1 #4 - #14 4 3 LD2570-1 0LD25701Z
175 2 2⁄0 - #14 1 #4 - #14 4 3 LD2570-2 0LD25702Z
175 3 2⁄0 - #14 1 #4 - #14 4 3 LD2570-3 0LD25703Z
175 1 2⁄0 - #14 1 #4 - #14 4 3 LD2970-1 0LD29701Z
175 2 2⁄0 - #14 1 #4 - #14 4 3 LD2970-2 0LD29702Z
175 3 2⁄0 - #14 1 #4 - #14 4 3 LD2970-3 0LD29703Z
335 1 400mcm - #6 1 #2 - #14 4 5 LD3552-1 0LD35521Z
335 2 400mcm - #6 1 #2 - #14 4 5 LD3552-2 0LD35522Z
335 3 400mcm - #6 1 #2 - #14 4 5 LD3552-3 0LD35523Z
335 1 400mcm - #6 1 #2 - #14 6 5 LD3553-1 0LD35531Z
335 2 400mcm - #6 1 #2 - #14 6 5 LD3553-2 0LD35532Z
335 3 400mcm - #6 1 #2 - #14 6 5 LD3553-3 0LD35533Z
350 1 2⁄0 - #14 2 #4 - #14 6 5 LD3555-1 0LD35551Z
350 2 2⁄0 - #14 2 #4 - #14 6 5 LD3555-2 0LD35552Z
350 3 2⁄0 - #14 2 #4 - #14 6 5 LD3555-3 0LD35553Z
380 1 500mcm - #4 1 #2 - #14 6 5 LD3953-1 0LD39531Z
380 2 500mcm - #4 1 #2 - #14 6 5 LD3953-2 0LD39532Z
380 3 500mcm - #4 1 #2 - #14 6 5 LD3953-3 0LD39533Z
350 1 2⁄0 - #14 2 #4 - #14 6 5 LD3955-1 0LD39551Z
350 2 2⁄0 - #14 2 #4 - #14 6 5 LD3955-2 0LD39552Z
350 3 2⁄0 - #14 2 #4 - #14 6 5 LD3955-3 0LD39553Z
380 1 500mcm - #4 1 #2 - #14 6 6 LD4551-1 0LD45511Z
380 2 500mcm - #4 1 #2 - #14 6 6 LD4551-2 0LD45512Z
380 3 500mcm - #4 1 #2 - #14 6 6 LD4551-3 0LD45513Z
335 1 400mcm - #6 1 #2 - #14 8 6 LD4560-1 0LD45601Z
335 2 400mcm - #6 1 #2 - #14 8 6 LD4560-2 0LD45602Z
335 3 400mcm - #6 1 #2 - #14 8 6 LD4560-3 0LD45603Z
380 1 500mcm - #4 1 #2 - #14 12 7 LD5552-1 0LD55521Z
380 2 500mcm - #4 1 #2 - #14 12 7 LD5552-2 0LD55522Z
380 3 500mcm - #4
380 1 500mcm - #4 1 2⁄0 - #14 6 7 LD5579-1 0LD55791Z
380 2 500mcm - #4 1 2⁄0 - #14 6 7 LD5579-2 0LD55792Z
380 3 500mcm - #4 1 2⁄0 - #14 6 7 LD5579-3 0LD55793Z
760 1 500mcm - #4 2 2⁄0 - #14 8 7 LD5586-1 0LD55861Z
760 2 500mcm - #4 2 2⁄0 - #14 8 7 LD5586-2 0LD55862Z
760 3 500mcm - #4 2 2⁄0 - #14 8 7 LD5586-3 0LD55863Z
665 1
665 2
665 3
poles
500mcm - #4 1
350mcm - #6 1
500mcm - #4 1
350mcm - #6 1
500mcm - #4 1
350mcm - #6 1
line loaD
wire
range
openings
per pole
1 #2 - #14 12 7 LD5552-3 0LD55523Z
wire
range
2⁄0 - #14 4 7 LD5587-1 0LD55871Z
2⁄0 - #14 4 7 LD5587-2 0LD55872Z
2⁄0 - #14 4 7 LD5587-3 0LD55873Z
openings
per pole
outline
Drawing
Figure
Catalog/system
number
2
© JUNE 2011 Littelfuse POWR-GARD Productswww.littelfuse.com
POWR-GARD
®
Fuseblocks
Distribution/spliCer bloCks anD Covers
Distribution Block Selection Guide
ConneCtor ConFiguration
material line loaD
AL
AL
CU
CU
AL
AL
CU
amp
rating
per
pole
760 1 500mcm-#4 2 #4 - #14 12 7 LD5592-1 0LD55921Z
760 2 500mcm-#4 2 #4 - #14 12 7 LD5592-2 0LD55922Z
760 3 500mcm-#4 2 #4 - #14 12 7 LD5592-3 0LD55923Z
380 1 500mcm-#4 1 #2 - #14 8 7 LD5594-1 0LD55941Z
380 2 500mcm-#4 1 #2 - #14 8 7 LD5594-2 0LD55942Z
380 3 500mcm-#4 1 #2 - #14 8 7 LD5594-3 0LD55943Z
760 1 500mcm-#4 2 2⁄0 - #14 8 7 LD5986-1 0LD59861Z
760 2 500mcm-#4 2 2⁄0 - #14 8 7 LD5986-2 0LD59862Z
760 3 500mcm-#4 2 2⁄0 - #14 8 7 LD5986-3 0LD59863Z
760 1 500mcm-#4 2 #2 - #14 12 7 LD5992-1 0LD59921Z
760 2 500mcm-#4 2 #2 - #14 12 7 LD5992-2 0LD59922Z
760 3 500mcm-#4 2 #2 - #14 12 7 LD5992-3 0LD59923Z
175 1 2⁄0 - #14 1 #4 - #14 4 4 LD2570-1DIN 0LD25701ZXDIN
175 2 2⁄0 - #14 1 #4 - #14 4 4 LD2570-2DIN 0LD25702ZXDIN
175 3 2⁄0 - #14 1 #4 - #14 4 4 LD2570-3DIN 0LD25703ZXDIN
175 Adder 2⁄0 - #14 1 #4 - #14 4 4 LD2570-ADIN 0LD2570AZXDIN
175 1 2⁄0 - #14 1 #4 - #14 6 4 LD2580-1DIN 0LD25801ZXDIN
175 2 2⁄0 - #14 1 #4 - #14 6 4 LD2580-2DIN 0LD25802ZXDIN
175 3 2⁄0 - #14 1 #4 - #14 6 4 LD2580-3DIN 0LD25803ZXDIN
175 Adder 2⁄0 - #14 1 #4 - #14 6 4 LD2580-ADIN 0LD2580AZXDIN
175 1 2⁄0 - #14 1 #4 - #14 4 4 LD2970-1DIN 0LD29701ZXDIN
175 2 2⁄0 - #14 1 #4 - #14 4 4 LD2970-2DIN 0LD29702ZXDIN
175 3 2⁄0 - #14 1 #4 - #14 4 4 LD2970-3DIN 0LD29703ZXDIN
175 Adder 2⁄0 - #14 1 #4 - #14 4 4 LD2970-ADIN 0LD2970AZXDIN
poles
line loaD
wire
range
openings
per pole
wire
range
openings
per pole
outline
Drawing
Figure
Catalog/system
number
AL=Aluminum, CU= Copper
Hinged Plastic Covers
Clear Plastic Covers
3
© JUNE 2011 Littelfuse POWR-GARD Productswww.littelfuse.com