Engine Control
Basic
M2000 SERIES
Engine Control
Wiring Diagram
LOCAL
1
START
AUTO
2
START
MODE
3
4
INPUTS
15
M2000
ENGINE CONTROLLER
CIRCUIT
16
CHECK
+
28
24 V
–
17
27
30
31
3229
OUTPUTS
Description
The M2000 Engine Control controls start and stop of the
engine, monitors and protects the engine during start and
operation, and simultaneously indicates the engine and alarm
status on the front of the unit. It has 9 shutdown/alarm inputs.
It is controlling the cranking, fuel valve and stop solenoid of
the engine. It is possible to configure the unit to perform up
to 6 start attempts, with user configurable crank and rest
periods. When the engine fires, cranking will be disconnected
by activating the crank disconnect input from a tacho relay or
from a direct measurement from a magnetic pick up. When
stopping the engine, a generator circuit breaker trip is available
for genset applications. A stop delay can be configured for
cooling down the engine before stop. M2000 includes cable
check of all sensor inputs. Basic configuration can be set by
dip-switches on the rear of the unit.
Extended configuration is possible using a PC. Easy installation
is ensured by means of clamping fittings, and plug-in
connection terminals. The M2000 includes an RS485 interface
enabling MODBUS RTU communication. The M2000 has been
designed and tested for use in harsh environments.
Features & Benefits
FEATURES BENEFITS
8 Alarm/shutdown
inputs
Cable monitoring on
sensor inputs
Speed detection from
magnetic pick-up
Type-approved by marine
classification societies
RS485 Modbus RTU Communication with HMI and SCADA systems
Monitoring of e.g. oil pressure, coolant
temperature and engine speed
Fail safe s ystem
No tacho relay required
Applicable in marine control and alarm systems
Accessories
M0500 Tacho Detector
Reads engine speed from frequency of the
generator output voltage. The reading is
converted to a square wave signal and this
signal is provided on a dedicated output.
K3452 RS232 Cable
For configuration from PC.
Ordering Information
ORDERING NUMBER CONTROL POWER
M2000.0130 12 V–24 Vdc, IP54 at front.
ACCESSORIES REQUIREMENT
M0500 Optional
K3452 Optional
Specifications
Voltage Supply 12-24 Vdc±30% (8-32 Vdc)
Consumption Max. 180 mA
Inputs 7 normally open contacts; 1 tacho voltage;1 pick-up
Tacho Input Square or sine wave between 0 Vdc and
supply voltage
Pick-up Input Square or sine wave, range 2.5 Vac to 33 Vac
Tolerance, Freq. Meas. ±2%
Frequency Range 50 Hz to 10 kHz
Outputs 11 open collector outputs, max. 150 mA per channel
Siren Relay Contact 230 Vac/2 A; 30 Vdc/2 A, 30 W
Tolerance, Delays ± 2%
LED Flash Frequency Slow flashing light: 1.25 Hz ±10%
Quick Flashing Light 5 Hz ±10%
Programming 16 dip-switches or via RS232 inter face
Communication RS485 interface
Protocol MODBUS-RTU
Baud Rate 1200, 2400, 4800, 9600
Parit y None
Data Bits 8
Stop Bits 1
Operating Temp. –20°C to +70°C
Humidity 95% RH at 20°C
Vibration Test 4 g RMS according to IEC 60068-2-64
Approvals Certified by major marine classification societies
Burn-in 50 hours before final test
Weight 0.4 kg
Dimensions H 144 mm (5.7”); W 144 mm (5.7”); D 35 mm (1.4”)
Panel Cut-out H 138 mm (5.4”); W 138 mm (5.4”)
Protection Degree-Front IP54 or IP32 (see Type Description)
© 2013 Littelfuse Protection Relays & Controls
www.littelfuse.com/m2000
Rev: 4-A-050313