Littelfuse CB Boxed User Manual

16 CIRCUIT BREAKERS
Type I – Automatic Reset
Cycles or continuously resets until the fault is corrected.Type I circuit breakers are typically used to protect circuits which occasionally experience momentary overloads such as wiper motor and headlamp circuits where a self resetting device is preferred.
Type II – Modified Reset
Non-cycling, remains in open position while there is power to the circuit. Resets when ignition is turned off.Type II circuit breakers are typically used in applica­tions where fuse replacement is objectionable, such as power window, seat and sunroof circuits.
Type III – Manual Reset
Manually resettable circuit breakers remain in the open position until a button, lever or other external reset device is manually depressed.Type III circuit breakers are typically used in applications where a manual reset is desired for safe diagnosis of a circuit fault.
Bulk
Part No.
MMB 15 MMB 20
MNB 10 MNB 15 MNB 20 MNB 25
MNB 30
US
Carded No.
MMB 15 BP MMB 20 BP
MNB 10 BP MNB 15 BP MNB 20 BP MNB 25 BP
MNB 30 BP
Amp
Rating
15 20
10 15 20 25
30
Typical Application
Heavy Truck Headlamp Automotive Headlamp
Heavy Duty Truck Heavy Duty Truck Automotive/Heavy Truck Automotive/Heavy Truck
Automotive/Heavy Truck
OEM No.
GM# 12135171 GM# 12135072
GM# 12135162 GM# 12135164 GM# 12077861 GM# 12077862 GM# 12088575 GM# 12077863
Wide Mini Footprint Circuit Breakers:
Direct factory replacement for many domestic OEM applications.Designed to fit either in an ATO
®
or MINI®Blade fuse block or panel.Their blade configuration is of the MINI design and fit in a standard ATO fuse slot or across two MINIslots. Available in either SAE Type I cycling or SAE Type II non-cycling used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J553C standard.
Bulk
Part No.
MIB 5 MIB 10 MIB 15 MIB 20 MIB 25 MIB 30
US & Canadian
Carded No.
MIB 5 BP MIB 10 BP MIB 15 BP MIB 20 BP MIB 25 BP MIB 30 BP
Amp
Rating
5 10 15 20 25 30
MINI®Circuit Breakers
Standard Mini Footprint Circuit Breakers:
Designed to fit in a MINI
®
Blade fuse block or panel.SAE Type II used primarily as a wiring
harness protector in 12 volt DC automotive systems.Conforms to SAE J553C standard.
Cycling Design – Type I
Non-Cycling Design – Type II
Bulk
Part No.
ACB 20 ACB 30
FCB 20 CCB 25
US
Carded No.
ACB 20 BP ACB 30 BP
FCB 20 BP CCB 25 BP
Canadian
Carded No.
ACB 20 CABP ACB 30 CABP
FCB 20 CABP CCB 25 CABP
Amp
Rating
20 30
20 25
Typical Application
Automotive Headlamp Power Windows , & Locks Power Windows
Headlamps, Power Windows, Seats & Locks
OEM No.
GM# 12040816 GM# 01252240 Chrysler# 83507005 Ford# D9AB-14526-BA
Chrysler# 4527053
Breaker
Type
Type I
Type II Type II
Type I
Specialty OEM Circuit Breakers
Direct factory replacement for many domestic OEM vehicles.SAE Type I and Type II modified reset used primarily as a wiring harness protector in 12 volt DC automotive systems. Conforms to SAE J553C standard. Designed to mount in ATO style fuse blocks and panels.
CIRCUIT
BREAKERS
ACB FCB
MNB
MMB
CCB
MIB
Loading...