Industrial High Energy Terminal Varistors > BA/BB Series
BA/BB Varistor Series
BB Series
Agency Approvals
AgencyAgency File Number
E320116 - for BA Series only.
BA Series
RoHS
Description
The BA and BB Series transient surge suppressors are
heavy-duty industrial Metal-Oxide Varistors (MOVs)
designed to provide surge protection for motor
controls and power supplies used in oil-drilling, mining,
transportation equipment and other heavy industrial AC line
applications.
These UL– recognized varistors have similar package
construction but differ in size and ratings. The BA models
are rated from 130 to 880V
to 2800V
M(AC)
.
. The BB models from 1100
M(AC)
Both the BA and BB Series feature improved creep and
strike capability to minimize breakdown along the package
surface, a package design that provides complete electrical
isolation of the disc subassembly, and rigid terminals to
ensure secure wire contacts.
See BA/BB Series Device Ratings and Specifications Table
for part number and brand information.
Features
• High energy absorption
capability W
TM
BA Series 3200J
BB Series 10,000J
• Wide operating voltage
range V
M(AC)RMS
BA Series 130V to 880V
BB Series 1100V to 2800V
• Rigid terminals for
secure wire contact
• Case design provides
complete electrical
isolation of disc
subassembly
• Littelfuse largest
packaged disc
60mm diameter
• No derating up to
85ºC ambient
RoHS compliant
•
Absolute Maximum Ratings
• For ratings of individual members of a series, see Device Ratings and Specifications chart
ContinuousBA SeriesBB SeriesUnits
Steady State Applied Voltage:
AC Voltage Range (V
DC Voltage Range (V
Transients:
Peak Pulse Current (ITM)
For 8/20μs Current Wave (See Figure 2)50,000 to 70,00070,000A
Single Pulse Energy Range
For 2ms Current Squarewave (W
Operating Ambient Temperature Range (T
Storage Temperature Range (T
Temperature Coefficient (a
)-55 to +125-55 to +125
STG
V
) of Clamping Voltage (VC) at Specified Test Current<0.01<0.01%/OC
Hi-Pot Encapsulation (COATING Isolation Voltage Capability)
(Dielectric must withstand indicated DC voltage for one minute per MIL–STD–202, Method 301)
COATING Insulation Resistance10001000MΩ
CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only
rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is
not implied.
Industrial High Energy Terminal Varistors > BA/BB Series
Power Dissipation Ratings
100
90
80
70
60
50
40
30
20
PERCENT OF RATED VALUE
10
0
-55 50 60 70 80 90 100 110 120 130 140 150
Figure 1Figure 2
AMBIENT TEMPERATURE (
o
C)
Peak Pulse Current Test Waveform
Should transients occur in rapid succession, the average power
dissipation required is simply the energy (watt-seconds) per pulse
times the number of pulses per second. The power so developed
must be within the specifications shown on the Device Ratings
and Characteristics Table for the specific device. Furthermore,
the operating values need to be derated at high temperatures as
shown in the above diagram. Because varistors can only dissipate
a relatively small amount of average power they are, therefore, not
suitable for repetitive applications that involve substantial amounts
of average power dissipation.
100
90
50
10
PERCENT OF PEAK VALUE
O
1
T
T
1
T
2
TIME
01 = Virtual Origin of Wave
T = Time from 10% to 90% of Peak
T1 = Rise Time = 1.25 x T
T2 = Decay Time
Example - For an 8/20 μs Current Waveform:
8μs = T1 = Rise Time
20μs = T2 = Decay Time
Stand by Power Dissipation vs Applied V
Temperatures
TYPICAL TEMPERATURE COEFFICIENT
OF POWER DISSIPATION = 2.2%/
1. 0
MAX AT TA = 85oC
0.8
0.6
0.4
RMS
MAX AT TA = 25oC
0.2
0.1
OF RATED V
TYP AT TA = 25oC
0.08
0.06
POWER DISSIPATION (W) PER kV
0.04
8090100110
PERCENTAGE OF MAXIMUM RATED V
o
C
at Varied
Rms
RMS
(%)
Typical Stability of Standby Power Dissipation at Rated
V
Industrial High Energy Terminal Varistors > BA/BB Series
Maximum Clamping Voltage BA Series
V131BA60 - V881BA60
6,000
MAX CLAMPING VOLTAGE
5,000
DISC SIZE 60mm
4,000
130 TO 880V
3,000
= -55oC TO 85oC
T
A
2,000
V881BA60
V751BA60
V661BA60
V571BA60
1,000
900
800
700
V321BA60
600
V271BA60
500
V251BA60
MAXIMUM PEAK VOLTS (V)
400
V151BA60
300
V131BA60
200
-210-1
10
Figure 5Figure 6
RATING
M(AC)
10010110210310410
PEAK AMPERES (A)
V511BA60
V481BA60
V421BA60
Repetitive Surge Capability BA Series
V131BA60 - V321BA60
50,000
20,000
10,000
5,000
2,000
1,000
SURGE CURRENT (A)
Figure 7Figure 8
500
200
100
50
20
10
10
10
10
10
10
6
10
INDEFINITE
20
1
2
3
4
5
2
100
IMPULSE DURATION (μs)
DISC SIZE 60mm
V131BA60 - V321BA60
1,00010,000
Maximum Clamping Voltage BB Series
V112BB60 - V282BB60
Repetitive Surge Capability BB Series
V421BA60 - V282BB60
30,000
MAX CLAMPING VOLTAGE
DISC SIZE 60mm
1100 TO 2800V
20,000
T
= -55oC TO 85oC
A
10,000
9,000
8,000
7,000
6,000
V282BB60
5,000
V242BB60
V202BB60
4,000
MAX PEAK VOLTS (V)
V172BB60
3,000
V142BB60
V112BB60
2,000
-210-1
10
100,000
1
50,000
20,000
10
10,000
SURGE CURRENT (A)
2
5,000
10
3
10
2,000
4
1,000
10
500
5
10
200
6
100
10
50
20
10
INDEFINITE
201001,00010,000
RATING
M(AC)
10010110210310410
PEAK AMPERES (A)
DISC SIZE 60mm
V421BA60 - V282BB60
2
IMPULSE DURATION (μs)
5
NOTE: If pulse ratings are exceeded, a shift of VN(DC) (at specified current) of more than +/-10% could result.This type of shift, which normally results in a decrease of VN(DC), may result in
the device not meeting the original published specifications, but it does not prevent the device from continuing to function, and to provide ample protection.