Littelfuse 370 User Manual

Radial Lead Fuses
TR5® > Fast-Acting > 370 Series
370 Series, TR5®, Fast-Acting Fuse
Agency Approvals
Agency Agency File Number Ampere Range
License number: 5007679-1170-0001/82438
License number: 5007679-1170-0001/97059 5007679-1170-0009/97069 5007679-1170-0002/82443
Certificate number: 1012264
File number: E67006
JET0381-31007-2003 1A - 5A
2007010207240347 50mA - 5A
100mA - 5A
50mA - 80mA
50mA - 6.3A
40mA - 6.3A
40mA
6.3A
Description
The 370 Series are TR5®,sub-miniature,fast-acting type, 250V rated fuses, designed in accordance to IEC 60127-3.
Features
• ReducedPCBspace
requirements
• Directsolderableor plug-in versions
• Internationallyapproved
• Vibrationresistant
• Halogenfree
• Lead-free
• Availablefrom40mA
to 6.3A
• Lowinternalresistance
• Shocksafecasing
Applications
• BatteryChargers
• ConsumerElectronics
• Powersupplies
• IndustrialControllers
Additional Information
Datasheet
Resources
Samples
Electrical Characteristics
% of Ampere
Rating
150% 1 Hour, Min.
210% 30 Minutes, Max.
275% 10 ms, Min. ; 3 Sec., Max.
400% 3 ms, Min. ; 300 ms, Max.
1000% 20 ms, Max.
© 2013 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 12/19/13
Opening Time
Electrical Characteristics
Radial Lead Fuses
TR5® > Fast-Acting > 370 Series
Amp
Code
Rated
Current
Voltage
Rating
0040 40mA 250V
Breaking Capacity
Voltage
Drop
1.0×I
N
max. (mV)
Power
Dissipation
1.5×I
N
max. (mW)
900 100 0.0002
Melting Integral
10×I
max. (A
0050 50mA 250V 320 80 0.00035 0063 63mA 250V 350 100 0.0005 0080 80mA 250V 370 120 0.0014
0100 100mA 250V 600 130 0.0038 0125 125mA 250V 550 172 0.0066
0160 160mA 250V 500 165 0.014 0200 200mA 250V 465 190 0.03 0250 250mA 250V 400 250 0.051 0315 315mA 250V 380 250 0.1 0400 400mA 250V 120 135 0.025
35 A/ 250VAC
50-60 Hz cos ϕ = 1.0
1
0500 500mA 250V 120 155 0.042 0630 630mA 250V 115 200 0.076 0800 800mA 250V 120 310 0.12
110 0 1.00A 250V 110 310 0.2
112 5 1.25A 250V 100 360 0.31
116 0 1.60A 250V 100 600 0.53 1200 2.00A 250V 85 500 0.98 1250 2.50A 250V 80 660 1.8 1315 3.15A 250V 90 950 3.1 1400 4.00A 250V 40 A / 250 VAC 80 920 6.7 1500 5.00A 250V 50 A / 250 VAC 80 1000 12.00 1630 6.30A* 250V 63 A / 250 VAC 70 1200 24.00
1 Per UL, approved breaking capacity is 50 A at 250 V. * Conducting path min. 0.2 mm G = Expert Report pending Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand.
2
Agency Approvals
N
2
s)
G X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X G X X
140
120
100
80
60
40
PERCENTOF RATING
20
0
-40-20 020406080
23°C
AMBIENTTEMPERATURE(°C)
Average Time Current CurvesTemperature Rerating Curve
100000
100000
10000
10000
1000
1000
100
100
10
10
TIME IN SECONDS
TIME IN SECONDS
1
1
0.100
0.100
0.010
0.010
0.001
0.001
0.080A
0.080A
0.040A
0.125A
0.040A
0.125A
0.050A
0.063A
0.100A
0.050A
0.063A
0.100A
0.100 1 10 1000.02
0.100 1 10 1000.02
0.630A
1.60A
0.630A
0.160A
0.200A
0.250A
0.315A
0.400A
0.160A
0.200A
0.250A
0.315A
0.400A
CURRENT IN AMPERES
CURRENT IN AMPERES
1.60A
0.500A
0.800A
0.500A
0.800A
1.00A
1.25A
1.00A
1.25A
3.15A
4.00A
5.00A
6.30A
3.15A
4.00A
5.00A
6.30A
2.00A
2.50A
2.00A
2.50A
Specifications are subject to change without notice.
© 2013 Littelfuse, Inc.
Revised: 12/19/13
Loading...