Axial Lead & Cartridge Fuses
3AB > Fast-Acting > 314/324 Series
314/324 Series Lead-free 3AB, Fast-Acting Fuse
PS
E
Description
The 3AB Fast-Acting Fuse with ceramic body construction
permits higher interrupting ratings and voltage ratings. Ideal
for applications where high current loads are expected.
Features
• InaccordancewithUL
Standard 248-14
• RoHScompliantand
Lead-free
• Availableincartridge
and axial lead format
and with various forming
dimensions
Agency Approvals
Agency Agency File Number Ampere Range
E10480 375mA - 15A
LR 29862 375mA - 20A
E10480 15A* - 40A
PS
E
NBK 030805 - E10480A-F
NBK 260106 - JP1021A/B
SU05001 -
6001/6002/6003/7006/8002/8003
375mA - 30A
375mA - 30A
375mA - 30A
Applications
Used as supplementary protection in appliance or
utilization equipment to provide individual protection for
components or internal circuits.
Electrical Characteristics for Series
% of Ampere
Rating
100% 1/8 - 40 4 hours, Minimum
135% 1/8 - 30 1 hour, Maximum
200%
250% 40 30 secs., Maximum
Ampere Rating Opening Time
1/8 - 12 15 secs., Maximum
15 - 30 30 secs., Maximum
Electrical Specification by Item
Agency Approvals
x x
AC
DC
AC
DC
AC
DC
DC
AC
DC
DC
AC
AC
AC
AC
Nominal
Cold
Resistance
(Ohms)
0.820 0.050
0.189 0.690
0.0470 10.4 x x x x x
AC
0.00355 631 x x x x x
0.00235 1450 x x x x
AC
0.0014 22925 x x
Nominal
Melting
2
t (A2 sec)
I
x x x
x x x
x x x
x x x x
x x x x
Ampere
Amp
Code
.375 0.375 250
.500 0.5 250 0.500 0.115
.750 0.75 250 0.250 0.466
0 01. 1 250
002. 2 250 0.0700 11.0
003. 3 250 0.0432 14.6 x x x x x
004. 4 250
005. 5 250 0.0300 26.0 x x x x x
006. 6 250 0.0240 45.0 x x x x x
0 0 7. 7 250 0.0187 71.0 x x x x x
008. 8 250 0.0153 105 x x x x x
010. 10 250 0.0105 206 x x x x x
012. 12 250 0.00760 570 x x x x x
015. 15 250 0.00505 292 x x x x x
015.* 15 280 0.00505 292
020. 20 250
020.* 20 280 0.00355 631 x x
025. 25 250
025.** 25 280 0.00235 1450 x x
030. 30 250 0.00182 2490 x x x x
040. 40 250
Rating
(A)
Voltage
Rating
(V)
Interrupting
Rating
35 A @ 250 VAC
10 kA @ 125 VAC
10 kA @ 125 VDC
100 A @ 250 V
10
kA
@ 125 V
10
kA
@ 125 V
750 A @ 250 V
10
kA
@ 125 V
10
kA
@ 125 V
1000 A @ 250 V
200 A @ 300 V
10
kA
@ 125 V
10
kA
@ 125 V
100 A @ 250 V
1000A @ 75 V
400A @ 125 V
400 A @ 125 V
1000 A @ 250 V
400 A @ 150 V
* 350A@280VAC interrupting rating available for 15A and 20A. ** 50A@280VAC for 25A. Add suffix ’280’. Example: 0324020.MX280P.
I2t test at 10x rated current
© 2013 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised: 12/19/13

Axial Lead & Cartridge Fuses
Temperature (°C) - Measured on bottom side of board
3AB > Fast-Acting > 314/324 Series
Temperature Rerating Curve
Average Time Current Curves
.375A
.500A
1000
100
10
TIME IN SECONDS
1
0.1
0.01
0.1 110100 1000
.750A1A2A3A4A5A6A7A8A
CURRENT IN AMPERES
10A
12A
15A
20A
25A
30A
40A
Soldering Parameters - Wave Soldering
280
260
240
220
200
180
160
140
120
100
80
60
40
20
0
0
102030405060708090
Time (Seconds)
Preheat Time
100
110
120
130
140
150
160
170
180
190
200
210
220
Dwell Time
Cooling Time
Recommended Process Parameters:
Wave Parameter Lead-Free Recommendation
Preheat:
(Depends on Flux Activation Temperature)
Temperature Minimum:
Temperature Maximum:
Preheat Time: 60-180 seconds
Solder Pot Temperature:
Solder Dwell Time: 2-5 seconds
230
Recommended Hand-Solder Parameters:
Solder Iron Temperature: 350° C +/- 5°C
Heating Time: 5 seconds max.
(Typical Industry Recommendation)
100
° C
150
° C
260
° C Maximum
Note: These devices are not recommended for IR or
Convection Reflow process.
Specifications are subject to change without notice.
© 2013 Littelfuse, Inc.
Revised: 12/19/13