Safe-T-Plus Fuse 259 Series
Agency Agency File Number Ampere Range
Baseefa
Baseef02ATEX0071U IECEx BAS 10.0098U
E10480 62mA - 5A
62mA - 5A
Baseefa
Description
The Safe-T-Plus 259 Series offers a range of encapsulated fuses designed to enable greater safety for operating electronic equipment within potentially explosive environments. Originally designed to serve the needs of gas plants, petrochemical and processing industries, these fuses are certitifed for use within intrinsically safe apparatus ATEx (EN 60079-0:2009 & EN 60079­11:2007), IECEx) IEC 60079-0:2007 & IEC 60079-11:2006).
The fuse design and its encapsulant are suitable for use in intrinsically safe appartatus for voltage not exceeding 125V rms (190V peak).
Features
• Hermeticallysealed
62mA - 5A range options
•
• Designedtooperate
within environments where there is danger of gas explosion from faulty circuits
• Meetcerticationfor
use within intrinsically safe apparatus for applications such as gas plants, petrochemical and processing industries
Applications
Electrical Characteristics for Series
• Testing,measuringor
% of Ampere
Rating
100% 4 Hours, Minimum
200% 5 Seconds, Maximum
Opening Time
processing electronic and electrical equipment
Additional Information
Datasheet
Resources
Samples
Electrical Specifications by Items
Ampere
Rating
(A)
0.062 .062
0.125 .125 1.70 0.0012 1.30 x x
0.250 .250 0.67 0.0095 0.83 x x
0.375 .375 0.395 0.025 0.81 x x
0.500 .500 0.302 0.0598 0.78 x x
0.750 .750 0.175 0.153 0.23 x x
1. 0 0 . 001 0.128 0.256 0.24 x x
3.00 .003 0.275 1.27 0.131 x x
5.00 .005
Schedule of limitations:
1) The fuse must be so mounted that creepage and clearance distances aren’t impaired in any way.
2) The fuse is suitable for use in intrinsically safe equipment for voltages not exceeding 190V peak.
3) Maximum surface temperature rise at 170% rated current ≤750mA=40ºC, 1A=55ºC, 3A=118ºC and 5A=135ºC.
Amp
Code
Interrupting
Rating
50A @ 125 VAC
300A @ 125 VDC
50A @ 125 VAC
300A @ 63 VDC
Nominal
Cold Resistance
(Ohms)
7. 0 0 0.00016 2.10 x x
0.0158 4.14 0.110 x x
Nominal Melting
2
t (A2 Sec.)
I
Nom
Voltage
Drop (mV)
Agency Approvals
Baseefa
© 2013 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 12/19/13
Special Application Fuses
259 Series
259 Series Safe-T-Plus Fuse
Product Characteristics
Operating Temperature – 55°C to 90°C
Thermal Shock
Withstands 5 cycles of – 55°C to 125°C
Vibration Per MIL-STD-202F
Insulation Resistance (After Opening)
Greater than 10,000 ohms
Soldering Parameters
Wave Soldering 260°C, 10 seconds max.
Dimensions
(.512")
13
mm
(.315")
8
mm
(.197")
(.025")
.635
mm
5
mm
(.394")
10
mm
Average Time Current Curves
.062 A
100
10
1
TIME IN SECONDS
0.1
0.01
0.001
0.1
.500 A
.375 A
.250 A
.125 A
1
CURRENT IN AMPERES
3.15 A
1 A
.750 A
Part Numbering System
0259.062M
5 A
10
100
1000
SERIES
AMP Code
The dot is poisitioned before the Packaging Suffix with whole ratings and within the numbering sequence for fractional ratings. Refer to Amp Code column in the Electrical Speci­fications table.
PACKAGING Code
M = Bulk pack, 1000 pcs T = Bulk pack, 10 pcs
Example:
1 amp product is
0259001. M (.062 amp product shown).
Specifications are subject to change without notice.
© 2013 Littelfuse, Inc.