Lithonia Lighting TWP-LED Installation Manual

Page 1
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
· To reduce the risk of death, personal injury or property damage from re, electric shock, falling parts, cuts/ abrasions, and other hazards please read all warnings and instructions included with and on the xture box and all xture labels.
· Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
· Installation and service of luminaires should be performed by a qualied licensed electrician.
· It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
· DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to conrm. Any part damaged or broken during or after assembly should be replaced.
· Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
· These instructions do not purport to cover all details or variations in equipment nor to provide every possible
contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered suciently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
Disconnect or turn o power before installation or
servicing.
Verify that supply voltage is correct by comparing it with
the luminaire label information.
Make all electrical and grounded connections in
accordance with the National Electrical Code (NEC) and any applicable local code requirements.
All wiring connections should be capped with UL approved
recognized wire connectors.
CAUTION
RISK OF INJURY
Wear gloves and safety glasses at all times when removing
luminaire from carton, installing, servicing or performing maintenance.
Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF BURN
Allow lamp/xture to cool before handling. Do not touch
enclosure or light source.
Do not exceed maximum wattage marked on luminaire
label.
Follow all manufacturer’s warnings, recommendations
and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF FIRE
Keep combustible and other materials that can burn,
away from lamp/lens.
Do not operate in close proximity to persons, combustible
materials or substances aected by heat or drying.
Page 2
Please see product specic installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Our Brands Indoor/Outdoor Indoor Lighting Outdoor Lighting Controls Daylighting
Lithonia Lighting Gotham American Electric Lighting DARK TO LIGHT SunOptics
Carandini Mark Architectural Lighting Antique Street Lamps LC&D Holophane Peerless Hydrel ROAM
RELOC Renaissance Lighng Tersen Sensor Switch Light Concepts Winona Lighting Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
Page 3
Installation Instructions TWP-LED
DELIVERY: Upon receipt of xture and accessories (packed separately), thoroughly inspect for any freight damage. All damage should be reported to the delivery carrier. Compare the catalog description listed on the packing slip with the xture label on the inside of the housing to be sure you have received the correct merchandise.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
5 year limited warranty
Outlet box mounting:
1. Loosen the 2 captive screws in the front housing and remove front cover from xture.
2. Remove electrical splice compartment cover. Keep (2) 8-32 screws for reinstallation.
3. Remove center knock out and feed wires through.
4. Mount xture using dimensions shown in Figure A. 4a. If provided with an ALO device, adjust the dial to the required lumen level (use ALO table as reference), by turning it using a small at head screwdriver.
5. Make supply connections. Reinstall the (2) 8-32 screws and electrical splice component cover removed in step 2, making sure no wires are pinched.
6. Replace front cover.
7. Tighten the 2 captive screws (30-35in lbs). Do not over tighten. Over tightening will cause stripping and void all warranties.
15-3/4”
Electrical splice compartment cover
Condulet Tee mounting:
1. Loosen the 2 captive screws in the front housing and remove front cover from xture.
2. Remove electrical splice compartment cover and driver cover. Keep (2) 8-32 and (2) 10-24 screws for reinstallation.
3. Remove top conduit cover disc.
4. Mount xture using dimensions shown in Figure A. Thread conduit into xture.
5. Make supply connections. Reinstall both compartment cover and driver cover using (2) 8-32 and (2) 10-24 screws removed in step 2, making sure no wires are pinched.
6. Replace front cover.
7. Tighten the 2 captive screws. Do not over tighten. Over tightening will cause stripping and void all warranties.
15-1/4”
3/8” KO (3)
1-13/16”
4-1/4”
7/8” KO
2-1/2”
Conduit cover disc
5”
2-7/8”
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
Phone: 800-279-8041 • Fax: 770.918.1209 • www.lithonia.com
© 2011 Acuity Brands Lighting, Inc. All rights reserved.
Part Number: RJ521354 REV C
Revision Date: 11-28-18
Page 4
Installation Instructions TWP-LED
FIXTURE MOUNT:
Figure D
Figure E
1. Drill xture per drilling detail (Figure D). NOTE: Remove photo­electric cell (when provided) before drilling for xture mounted wire
1”from wall
guard.
2. Place wire guard over xture.
7 1/2”
3. Secure in place with two (2) 10­24 fasteners, washers, and spacers (provided) as shown (Figure E).
Troubleshooting: If this xture fails to operate properly, check to make sure: • The xture is wired correctly. • The xture is grounded correctly. • The line voltage at the xture is correct. If all these variables have been checked and the xture still does not operate as specied, contact your local Lithonia Lighting distributor.