INTENDED USE — Provides a minimum of 90 minutes illumination for the rated wattage upon loss of
AC power to meet and exceed code required emergency lighting. Ideal for applications requiring attractive
LED unit equipment with quick installation and unparalleled performance for lower mounting heights.
Certain airborne contaminants can diminish the integrity of acrylic and/or polycarbonate.
Click here for Acrylic-Polycarbonate Compatibility table for suitable uses.
CONSTRUCTION — The housing is a standard white (black optional) thermoplastic with a compact and
low-profile contemporary design. It is 5VA flame rated, impact-resistant, scratch-resistant and corrosion
proof. The UV-stable resin resists discoloration from natural and man-made light sources. There is a
low-profile, integrated and back-lit test switch with an easily visible multi-color LED status indicator. The
back-plate contains a universal j-box mounting pattern to facilitate ease of installation on a wide variety of
j-boxes and the front housing allows tool-less access for ease of maintenance. US Patents Pending.
ELM2LF: Fixed lamp head arrangement for ease of installation and maximum path of egress aiming
coverage with no aiming required for wall mount applications.
ELM2L: Unique track and swivel arrangement permits full range of direction for lamp head adjustment.
OPTICS — Both the ELM2L and ELM2LF feature two, high performance LEDs with acrylic lens’ rated at 1.2
watts each and delivering a total of 220 lumens in a linear pattern (LP220L). The typical life of an LED is 10
years. The LED light sources typically never need to be replaced under normal conditions for normal
off applications.
ELECTRICAL — CCT: 5000K. Orderable in multiple voltages (see ordering tree for specific voltages).
Current-limiting charger maximizes battery life and minimizes energy consumption to meet California
Energy Commission Title 20 requirements for small battery charger systems and provides low
operating costs.
Regulated charge voltage maintains constant-charge voltage over a wide range of line voltages.
Prevents over/undercharging that shortens battery life and reduces capacity. Filtered charger input
minimizes charge voltage ripple and extends battery life.
BATTERY: Sealed, maintenance-free nickel-cadmium or Lithium Iron Phosphate.
Lithium Iron Phosphate battery powers both on board LEDs and up to 2.4W additional LED remote lamp
heads simultaneously or offers extended run-time up to 3 hours.
SELF-DIAGNOSTICS and REMOTE TEST (SDRT option):
Automatic 24-hour recharge after a 90-minute discharge.
Advanced electrical design provides constant light output throughout the entire discharge period.
Brownout protection is automatically switched to emergency mode when supply voltage drops below
approximately 80 percent nominal of 120, 220, 277 or 347. Other input voltages may vary.
AC/LVD reset allows battery connection before AC power is applied and prevents battery damage from
deep discharge.
Self-Diagnostics: Continuously monitors AC functionality. Test switch and remote tester (ELA LRT accessory)
provides manual activation of 30-second diagnostic testing for on-demand visual inspection. Standard
derangement monitoring will indicate disconnected battery, charger failure and displays green flashing
indicator light while in emergency mode. Single multi-chromatic LED indicator to display two-state
charging, test activation and three-state self-diagnostics.
Self-diagnostic testing: Five minutes every 30 days and 90 minutes annually. Diagnostic evaluation of
lamps, AC to DC transfer, battery charging and condition of microprocessor. Automatic test is easily postponed for eight hours by activating manual test switch or use of remote tester (ELA LRT accessory).
INSTALLATION — Wall mount and ceiling mount standard for ELM2L. Wall mount only for ELM2LF.
Blind-mate connector ensures easy installation and safe maintenance. 7/8" entrance provision at top of
unit for standard 1/2" conduit entry. Tool-less removal of front cover from back-plate for ease of installation
and maintenance.
LISTINGS — UL damp location listed standard and wet location listed when used with the WPVS
accessory, all at 50-104°F (10-40°C). Meets or exceeds all applicable requirements for UL 924, NFPA 101
(current Life Safety Code), NFPA 70 (NEC), NOM (Norma Oficial Mexicana), California Energy Commission
Title 20 section 1605.3 (W)(4), FCC and OSHA. List and labeled to comply with Canadian Standards
C22.2 No. 141-10.
WARRANTY — 5-year limited warranty. Complete warranty terms located at:
NOTE: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Specifications subject to change without notice.
Type
Contemporary Commercial LED Emergency Light
MOUNTING AND SPECIFICATIONS
All dimensions are inches (centimeters) unless otherwise indicated.
9.72 [24.69]
3.10 [7.87]
3.10 [7.87]
9.15 [23.24]
4.68 [11.88]
3.10 [7.87]
1.89 [4.80]
ELM2L
Aimable Optics
ELM2LF
Fixed Optics
LITHIUM IRON PHOSPHATE
Nickel Cadmium
4.68 [11.88]
ELM2L Specifications
Length: 9.72 (24.69)
Depth: 3.10 (7.87)
Height: 4.68 (11.88)
Weight: 1.31lbs (0.59kg)
3.10 [7.87]
ELM2LF Specifications
Length: 9.22 (23.42)
Depth: 3.10 (7.87)
Height: 4.68 (11.88)
Weight: 1.25lbs (0.57kg)
9.22 [23.42]
EMERGENCY ELM2LF_ELM2L
Pg. 1 of 3
Page 2
ELM2L_ELM2LF Quantum® Contemporary Commercial LED Emergency Light
1 Exte nded run-ti me or remote cap acity is st andard. New ELM RE style rem otes are compa tible with bo th SDRT and non-SD RT versions (se e page 3).
2 SDRT not co mpatible to ru n previous gen eration ELA s tyle remot es (see page 3).
3 WPVS brea ks out and ship s separately a nd color will ma tch (ex: WPVS SML B). Must b e ordered whe n using for wet lo cation appl ications. D ecreases de livered lumen s up to 20%. See sp ec sheet WPVS for more information.
SPACING GUIDELINES
*Note: To see co mplete photo metric repo rt or downlo ad the .ies file fo r this produc t,
visit Lithonia Lighting ELM2L or ELM2LF home page.
33'
1 FC average
3'
1 FC average
28'
Exampl e of single ELM2L illumin ating a 3' path of egres s.
7.5'
* Applic ation image ex amples are usi ng LP220L lamp.
3'
Example of multiple
ELM2L lumina ires
illuminat ing a 3' path
of egress.
Maximum Spacing Guidelines — ELM2LF
Single Luminaire
Mounting
Notes:
1. Also mee ts the additio nal illuminatio n requirement s of NFPA 101: .1FC minimum and ma x/min ration
Illumination
Height
7.5 '1FC Avg
10'1FC Avg
of 40:1.
Level
1
1
Coverage
3' Path of
Egress
6' Path of
Egress
32'20 '35'28'
20'NA27'24'
Multiple Luminaire
Spacing
3' Path of
Egress
6' Path of
Egress
Application
Notes
100' Corri dor,
8' wide, and
12' high with
80/50/20
reflectances
Maximum Spacing Guidelines — ELM2L
Single Luminaire
Mounting
Notes:
1. Also mee ts the additio nal illuminatio n requirement s of NFPA 101: .1FC minimum and ma x/min ration
Illumination
Height
7.5 '1FC Avg
10'1FC Avg
of 4 0:1.
Level
1
1
Coverage
3' Path of
Egress
6' Path of
Egress
28'20'33'27'
20'14'27 '23'
Multiple Luminaire
Spacing
3' Path of
Egress
6' Path of
Egress
Application
Notes
100' Corri dor,
8' wide, and
12' high with
80/50/20
reflectances
Other Accessories: Order as separate catal og number.
WPVS SML WWet pr otective vanda l shield (must be used fo r wet location app lications)
WPVS SML BWet p rotective van dal shield, black (must b e used for wet loca tion application s)
ELA WG1
ELA LRTRemote te st (laser) for dist ances up to 30'
Wireguar d, 15" W x 13-1/2" H x 6" D (see spec sheet EL A-WG)
ELM2L mount ed inside the WPVS (whit e)ELM2LF moun ted inside WPVS (white)
ELM2L_ELM2LF Quantum® Contemporary Commercial LED Emergency Light
INDOOR/ DAMP LOCATION REMOTES
ELMRE Compatible Remotes
LTP Compatible Remote Accessories: Order as separate cata log number.
ELMRE LP220L S GLSingle LED In door remote head, wh ite.
ELMRE LP220L TTwin LED Indo or remote heads, whi te.
ELMRE LP220L F XOTwin LED Indoor remo te heads, fixed lamps, w hite.
Notes
1 Compatible with SDRT and non-SDRT versions.
2 Order th e WPVS accesso ry for wet loc ation listi ng and vandal pro tection.
BATTER Y CAPACITY AN D LOADNG ELMRE RE MOTES
Battery OptionTotal CapacityMaxi mum # of Remote La mp heads
2- ELMRE LP220L S GL M12
LTP4.8W
* In additi on to the lamp heads o n the producto f 40:1.
1 - ELMRE LP220 L T M12
1 - ELMRE LP220 L FXO
OUTDOOR / WET LOCATION REMOTES
ELA Compatible Remotes (Non-SDRT versions on ly)
1
ELMRE LP220L S GL
ELMRE LP220L F XO
ELMRE LP220L T
ELMRE LP220L T w ith WPVS SML W
(order separately)
LTP Compatible Remote Accessories3: Order as separate cata log number.
ELA QWP L0309
Single LED wea ther-proof remote h ead, gray. See spec shee t ELA-Q-LED.
ELA LED WP M12S ingle LED Weather proo f remote lamp. See spec s heet ELA LED (Contractor Select
LED Remotes).
ELA LED T WP M12 Twin L ED Weather proof remo te lamp. See spec shee t ELA LED (Contractor Select
* These ar e in addition to t he lamp heads on t he product .
1 - ELA QWP L0309
1 - ELA LED T WP M12
SPECIFICATIONS
ELECTRICAL
Primary Circuit
Typ eVoltsInput ampsWatts
Nicad
Lithium I ron
Phosphate
LTP EXTENDED RUNTIMES
ProductsTotal Run-time with no remotes
ELM2L LTP3 hours
ELM2LF LTP3 hours
1200.0 181. 09
3470.0121.34
1200.0221.35
3470.0141.64
ELA QWP
ELA LED WP
ELA LED T WP
BATT ERY
Nicad (6V)
Typical Shelf life1Typical life
1
Maintenance
2
Temperature Range
3,4
3 years7-9 yearsnone50°-104°F (10-40°C)
Lithium Iron Phosphate (9.6V)
Typical Shelf life1Typical life
1
Maintenance
2
Temperature Range
3,4
1 years7-9 yearsnone50°-104°F (10-40°C)
Notes
1 At 77°F (25°C) ambient temperature, charge/discharge cycles and prolonged full discharge may reduce useful life.
2 All life s afety equi pment, inclu ding emergen cy lighting f or path of egre ss must be tes ted in accorda nce with all
Nationa l Fire Protec tion Assoc iation (NFPA) and loc al codes. Failu re to perfor m the require d testing cou ld jeopardi ze
the safe ty of occup ants and will voi d all warrant ies.
3 Ambient t emperature r ange where un it will provid e capacity f or 90 minutes . Higher and lowe r temperatur es affect
life and c apacity.
4 Batte ry life is neg atively impac ted by many var iables inclu ding tempera ture, chargin g rates, numbe r of cycles an d
deep dis charges due to l ong periods o f time withou t AC power.