SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
· To reduce the risk of death, personal injury or property damage from re, electric shock, falling parts, cuts/
abrasions, and other hazards please read all warnings and instructions included with and on the xture box and all
xture labels.
· Before installing, servicing, or performing routine maintenance upon this equipment, follow these general
precautions.
· Installation and service of luminaires should be performed by a qualied licensed electrician.
· Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and
operation and any hazards involved. Regular xture maintenance programs are recommended.
· It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on
ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a
solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry.
Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing
damaged gaskets as necessary.
· DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have
been damaged during transit. Inspect to conrm. Any part damaged or broken during or after assembly should be
replaced.
· Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
·These instructions do not purport to cover all details or variations in equipment nor to provide every possible
contingency to meet in connection with installation, operation, or maintenance. Should further information be
desired or should particular problems arise which are not covered suciently for the purchaser’s or owner’s
purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
Disconnect or turn o power before installation or
servicing.
Verify that supply voltage is correct by comparing it with
the luminaire label information.
Make all electrical and grounded connections in
accordance with the National Electrical Code (NEC) and
any applicable local code requirements.
All wiring connections should be capped with UL approved
recognized wire connectors.
CAUTION
RISK OF INJURY
Wear gloves and safety glasses at all times when removing
luminaire from carton, installing, servicing or performing
maintenance.
Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF BURN
Allow lamp/xture to cool before handling. Do not touch
enclosure or light source.
Do not exceed maximum wattage marked on luminaire
label.
Follow all manufacturer’s warnings, recommendations
and restrictions for: driver type, burning position,
mounting locations/methods, replacement and recycling.
CAUTION
RISK OF FIRE
Keep combustible and other materials that can burn,
away from lamp/lens.
Do not operate in close proximity to persons, combustible
materials or substances aected by heat or drying.
Page 2
Never connect components under load.
Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the
luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be
powered directly off a switched circuit.
Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some
volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that
will prevent convection or conduction cooling.
Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient
temperature.
Only use fixture in its intended location.
LED products are Polarity Sensitive. Ensure proper Polarity before installation.
Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn
during all installation or servicing of the unit.
Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter
performance.
Some components inside the fixture may not be serviceable. In the unlikely event your unit may require
service, stop using the unit immediately and contact an ABL representative for assistance.
Always read the fixtures complete installation instructions prior to installation for any additional fixture
specific warnings.
Always ensure that the electrical distribution system is up to NEC (and any applicable local code)
requirements.
Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture
failure and may void warranty.
CAUTION: RISK OF PRODUCT DAMAGE
Please see product specic installation instructions for additional warnings or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
DELIVERY: Upon receipt of xture and accessories (packed separately), thoroughly inspect for any freight damage. All damage should be reported to the delivery carrier. Compare the catalog description listed on the packing slip with the xture label on the inside of the housing to
be sure you have received the correct merchandise.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Prior to Installation--Read carefully before installing light xtures. If you do not understand these instructions, please contact your local Lithonia Lighting
distributor before installing.
NOTE: Horizontal mounting of a xture with the photocontrol receptacle option (PER)-- Section C136.10 ANSI, 4.5.2--The seat of the receptacle shall be
mounted as close to horizontal as possible. If it deviates more than 45° from horizontal, the integrity of the seal may be aected when a control device is
installed.
Tools Required: 9/64” and 3/16” hex key. 1/4" and 5/16” hex socket, regular screwdriver
1. Mounting
Threaded Knuckle Mount (THK): DSXF1 and DSXF2 Knuckle (1/2" NPT threaded nipple) or DSXF3 (3/4" NPT threaded nipple) mount directly to compatible NPTF apparatus. Secure the knuckle to desired mounting apparatus by tightening the locknut (not included). To adjust the tilt angle of the xture,
loosen the 3/16” hex key screw. Adjust as necessary and retighten to 75 in-lbs. Supply leads exit the knuckle mount to make connections in wiring
compartment (not provided).
Yoke Mount (YK):
For the center hole, it is recommended to use a 5/8” bolt with corresponding lock washer and nut. For the outer two holes or slots, it is recommended
to use ½” bolts with corresponding lock washers and nuts. NOTE: Mounting hardware is not included and it is up to the installer to determine the most
appropriate hardware for the desired mounting location. To adjust the tilt angle of the xture, loosen the hex socket screw on each side of the yoke.
While holding weight of xture, remove hexhead set screw, adjust as necessary and reinstall in appropriate matching hole. If a non-standard angle is
desired, adjust to angle and center punch inside yoke bracket and drill a .147in(#26) hole. Drive self-tapping hexhead set screw into new hole. Once the
appropriate angle is set, tighten hex socket set screws to 75in-lbs. Make the supply connections to the 16-3 cord supplied.
DSXF1
DSXF2 YOKE
2.25"
1.25"
4.76"
0.56
2.50"
Yoke Mounting Plate Templates
Note: This drawing is NOT to
scale and should be used for
0.75
0.56
2.00
dimensional purpose only.
0.51"
(2 plcs)
0.63"
thickness
0.13"
1.25
2.50
DSXF3
YOKE
DSXF1 with yoke
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012
DSXF1/DSXF2/DSXF3 (ships installed): Remove the access cover plate to the integral wiring compartment using a 1/4" hex socket or regular screwdriver.
Slip integral sliptter onto tenon ensuring that the wires are pulled through the integral wiring compartment without pinching. Secure the sliptter to the
tenon by tightening the 3/16” hex socket set screws to 12 ft-lbs. To adjust the tilt angle of the xture, loosen the 5/16” hex socket screw above the integral
wiring compartment. Adjust as necessary and retighten to 75 in-lbs. Make supply connections through the integral wiring compartment. There are two
wiring compartment cover plates, one without through hole and one that includes 7/8" through hole. If supply wires are coming through inside of tenon,
use the cover plate without through hole. Use the plate with through hole if supply wires are being routed from a source outside of the tenon, such as
surface or exible conduit. When using the plate with through hole, use connectors rated for liquid tight sealing. Push wires into compartment. Re-install
the access cover plate.
Shielding Options:
Attach with the 8-32 thread forming screws (provided) using the
pre-drilled holes in the doorframe. Should the doorframe holes need
be cleared for any reason, drill no deeper than 1/4" with a .147" (#26)
diameter drill.
UBV
UPPER or BOTTOM
VISOR
DSXF1 UV or BV
DSXF2 UV or BV
FV
FULL VISOR
DSXF1 FV
DSXF2 FVDSXF2 VG
VANDAL
VG
GUARD
DSXF1 VG
WG
WIRE GUARD
(DSXF3 only)
N/A
N/A
Tenon Sliptter (DSXF1/2TS) Installation
(for use with THK mounting option):
1/2-14 NPS
Attach DSXF1/2TS to xture’s threaded
1/2" knuckle.
2-1/2"
Secure to the top end of 1-1/4” to 2”
pipe by tightening set screws to 12 ft.lbs and lock down with jam nuts.
5/16-18 NPT
(3 places)
3-7/16"
nLight AIR rIO: Only available in DSXF2
1. Remove antenna tape and discard. (g 1)
2. Fasten female end of antenna to protruding male connector on
the cover plate. (g 2)
3. Fasten antenna torque to 3.5 in-lbs.
g 1
g 2
DSXF3 UV or BVDSXF3 FV
DSXF3 VG
DSXF3 WG
Troubleshooting: If this xture fails to operate properly, check to make sure: • The xture is wired correctly. • The xture is grounded correctly. • The
line voltage at the xture is correct. If all these variables have been checked and the xture still does not operate as specied, contact your local Lithonia Lighting distributor.
Lithonia Lighting Outdoor • One Lithonia Way • Conyers, Georgia 30012