WARRANTY
All fiber optic transmission systems, products and accessories manufactured by Liteway, Inc. and it’s subsidiaries are fully tested prior to shipment and are warranted against defective materials and workmanship for a period of five full years from the date of the original shipment. Should a problem occur, a Return Material Authorization Number (RMA) must be obtained from Liteway Inc. at (516) 931-2800 and the item returned to Liteway, Inc. 166 Haverford Road, Hicksville, NY 11801, USA, prepaid. Liteway Inc. will then, at its option repair or replace the defective item.
Liteway, Inc. maximum liability under this warranty is limited to the cost of the defective item only. No contingent liabilities of any kind are either assumed or implied.
Any items returned to Liteway, Inc. that have been misused, abused, damaged, modified, connected or adjusted in any way contrary to the instructions furnished by Liteway, Inc. or repaired by unauthorized personnel will not be covered by this warranty. Any non-warranty repairs required will be quoted at the current rate for such services.
!
CAUTION ! AVOID DIRECT EXPOSURE TO BEAM.
All -7,-8, and -9 Models use laser diodes. These solid-state laser diodes are located in the optical ports of these units. Laser diodes produce invisible radiation that may be harmful to human eyes. Never look directly into the optical port of any fiber optic unit designed to operate with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or accessories for use in critical life support systems or applications of any kind.
© Copyright 2017 Liteway, Inc. 106117 Rev G
Important Notices
OPERATING INSTRUCTIONS
Fiber Optic Video & Audio
Transmission System
Model VAT-1001, VAR-1001
The VAT/VAR-1001 system consists of the VAT-1001 transmitter and VAR-1001 receiver and will transmit high quality baseband video in accordance with NTSC, PAL and SECAM specifications as well as two line level audio channels over a single optical fiber.
Technical Specifications
Video Bandwidth 8 MHz Video In / Out 1 volt peak to peak , 75 Ohms, BNC In / Out Signal Level 1 volt peak to peak Signal / Noise Ratio 60 dB/min Differential Gain 3% max Differential Phase 3º max Audio Bandwidth 15 Khz Audio In / Out 1V RMS, 600 Ohms, ( 5 Pin terminal block) Optical Output -16 dBm typical Optical Loss Budget 0 – 13 dB Operating Wavelength 850 (-1), 1300 (-3,-7), 1550 (-9)
Fibers Accommodated Temperature Range -35º to +75ºC
Power Requirements 11-24 VAC/DC @150 mA (3 pin term. block) Physical Size (mm) 5.0”(127)L x 1.0” (25.4)W x 3.0”(7)D
All specifications measured with 1Km of 62.5u multimode fiber. All specifications are subject to change without prior notice.
1 multimode fiber, ST connector (-1,-3), or 1 single-mode fiber, FC/PC connector (-7,-9)
Installation Instructions
A
A
A
A
A
A
The diagram below shows the typical installation of the VAT-1001 and VAR-1001 fiber optic video/audio transmission units. Both should be connected as shown and a video signal applied to the transmitter. To compensate for the unique fiber optic losses of your installation there is a level adjustment on the VAR-1001. The receiver video Level adjustment should then be set for a 1 Volt pp video output signal, or for an acceptable picture. The range of the receiver level control is adequate to allow the full 0-13dB optical path loss range to be accommodated. The audio channels do not require any adjustments.
Link
larm Switch
Power
udio Input
Video Input
Indicator Lights
Indicator Lights when
Pwr Proper power is present. Alrm
Vat Internal circuitry is OK. Var A fiber optic link is present
Video A Video signal is being transmitted or received.
Power Terminal Block Connections
Pin Function
Alarm output for use with optional Alarm Sensing Unit
1
2 +11 to 24 DC or AC Volts input 3 AC or DC return (Common to Housing)
Be certain to check all connections, settings and voltages before applying power 106117 Rev G
ALM-1000. No other connections should be made to this terminal
larm
VAT-1002- VAR-1002-
Power
larm Switch
Fiber Optic Cable
LevelAdjustVideo
Power
Video
Link
larm
Power
Video Output
udio Output
The loss of video alarm is activated and there is no video present
Audio Removable Terminal Block Connections
Pin Function
1 Signal Channel 1 + 2 Signal Channel 1 -­3 Ground (common to housing) 4 Signal Channel 2 -­5 Signal Channel 2 +
The audio input and output are transformer coupled and may be used in either a balanced or an unbalanced configuration.
Balanced input or output:
Connect audio to Pin 1 and 2. (4 & 5 for channel 2) Pin 3 is then used as a shield or unconnected.
Unbalanced input or output:
Connect audio signal to Pin 1 (5 for channel 2). Connect audio return (and/or shield) to Pin 2 (4 for channel 2). Connect jump Pin 2 (4 for channel 2) to Pin 3 (ground).
In both cases be certain that the audio input level does not exceed 1­Volt RMS (3 volts peak-to-peak) or distortion and/or clipping will occur.
Alarm Switch
The Alarm is used to turn the video alarm function on and off. This is utilized when the Alarm sensing unit, ALM-1000 is being utilized.
Mic(line level)
Camera
Fiber Optic Cable
VAR-1000VAT-1000
Monitor
Audio
line-level
ALM-1000
Alarm
Contacts
Typical Fiber Optic CCTV System
Note that when there is a loss of signal carrier, usually due to broken fiber or excessive optical path loss, the Alarm indicator will light and the Link indicator will go off. The alarm switch cannot disable the function of the indicator lights.