WARRANTY
All fiber optic transmission systems, products and accessories
manufactured by Liteway, Inc. and it’s subsidiaries are fully tested
prior to shipment and are warranted against defective materials
and workmanship for a period of five full years from the date of the
original shipment. Should a problem occur, a Return Material
Authorization Number (RMA) must be obtained from Liteway Inc.
at (516) 931-2800 and the item returned to Liteway, Inc. 166
Haverford Road, Hicksville, NY 11801, USA, prepaid. Liteway Inc.
will then, at its option repair or replace the defective item.
Liteway, Inc. maximum liability under this warranty is limited to the
cost of the defective item only. No contingent liabilities of any kind
are either assumed or implied.
Any items returned to Liteway, Inc. that have been misused,
abused, damaged, modified, connected or adjusted in any way
contrary to the instructions furnished by Liteway, Inc. or repaired
by unauthorized personnel will not be covered by this warranty.
Any non-warranty repairs required will be quoted at the current
rate for such services.
!
CAUTION ! AVOID DIRECT EXPOSURE TO BEAM.
All –5, -7, -8, and -9 Models use laser diodes. These solid-state
laser diodes are located in the optical ports of these units. Laser
diodes produce invisible radiation that may be harmful to human
eyes. Never look directly into the optical port of any fiber optic
unit designed to operate with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or
accessories for use in critical life support systems or applications
of any kind.
© Copyright 2017 Liteway, Inc. 108515 Rev E
Important Notices
OPERATING INSTRUCTIONS
Redundant Signal
Switch
Model RSW-1002
The RSW-1002 is a two input single output automatic switch
designed to implement a redundant, fail-safe signal transmission
Technical Specifications
Video Bandwidth DC to 100 MHz
In/Out Impedance 75 ohms
In/Out Signal Level 3 volt peak to peak
Signal/Noise Ratio 75 dB/min
Differential Gain 0.5% max
Differential Phase 0.3º max
Field Tilt 1% max
Indicator Lights Pwr, Input 1, Input 2, Fault, Alarm
Signal Connectors BNC
Temperature Range -35º to +75ºC
Power Requirements 11-24 VAC/DC @150 mA
Physical Size (mm) 5.0”(127)L x 1.0” (25.4)W x 3.0”(7)D
All specifications are subject to change without prior notice.

Installation Instructions
The diagram below shows the typical installation of the RSW-1002
with VT-1001 and VR-1001 fiber optic video transmission units.
VT-1001
Camera
Camera
Typical Redundant Fiber Optic CCTV System
Upon loss of the primary video signal, the RSW-1002 will
automatically switch the remaining secondary (backup) video signal to
the output as well as activate the front panel alarm “Alm” indicator
and ALM-1000 Alarm Sensing Unit if used.
Fiber Optic Cable
VT-1001
Fiber Optic Cable
VR-1001 ALM-1000
VR-1001
Power Terminal Block Connections
Pin Function
Alarm output for use with optional Alarm Sensing Unit
1
ALM-1000. No other connections should be made to this
terminal
2 +11 to 24 DC or AC Volts input
3 AC or DC return (Common to Housing)
Be certain to check all connections, settings and voltages before
applying power
RSW-1002
Alarm
Contacts
Monitor
108515 Rev E
Mode Switch
Setting Function
Pri Forces Primary feed to common output
Auto mode;
If there is no signal on primary feed, but a signal
Auto
Sec Forces Secondary feed to common output
on the secondary feed, the secondary feed is
connected to common output. Otherwise,
Primary feed connects to common output.
Indicator Lights
Indicator Lights when
Pwr Proper power is present.
Alrm* One or both video input signals are not present
Pri A signal is present at Primary input
Sec A signal is present at Secondary input.
The loss of the signal at Input 1 (Primary) has
Fault
* Note that if the alarm “Alm” indicator is enabled the output for the
optional ALM-1000 Alarm Sensing Unit will also be enabled.
occurred and the video signal at Input 2 (Backup)
has been routed to the output.
5 Pin Control Terminal Block Connector Block
Pin Function
Relay contacts (2 Amp dry contact)
1 Normally Open Contact
2 Common Contact
3 Normally Closed Contact
External control of Mode (valid only when in Auto mode)
4 Ground to Force Primary output
5 Ground to Force Secondary output