WARRANTY
All fiber optic transmission systems, products and accessories manufactured by Liteway, Inc. and it’s subsidiaries are fully tested prior to shipment and are warranted against defective materials and workmanship for a period of five full years from the date of the original shipment. Should a problem occur, a Return Material Authorization Number (RMA) must be obtained from Liteway Inc. at (516) 931-2800 and the item returned to Liteway, Inc. 166 Haverford Road, Hicksville, NY 11801, USA, prepaid. Liteway Inc. will then, at its option repair or replace the defective item.
Liteway, Inc. maximum liability under this warranty is limited to the cost of the defective item only. No contingent liabilities of any kind are either assumed or implied.
Any items returned to Liteway, Inc. that have been misused, abused, damaged, modified, connected or adjusted in any way contrary to the instructions furnished by Liteway, Inc. or repaired by unauthorized personnel will not be covered by this warranty. Any non-warranty repairs required will be quoted at the current rate for such services.
!
CAUTION ! AVOID DIRECT EXPOSURE TO BEAM.
All –5, -7, -8, and -9 Models use laser diodes. These solid-state laser diodes are located in the optical ports of these units. Laser diodes produce invisible radiation that may be harmful to human eyes. Never look directly into the optical port of any fiber optic unit designed to operate with single-mode optical fiber.
NOT FOR LIFE SUPPORT SYSTEMS
Liteway, Inc. does not authorize or warrant any of its products or accessories for use in critical life support systems or applications of any kind.
© Copyright 2017 Liteway, Inc. 108515 Rev E
Important Notices
OPERATING INSTRUCTIONS
Redundant Signal Switch Model RSW-1002
The RSW-1002 is a two input single output automatic switch designed to implement a redundant, fail-safe signal transmission
Technical Specifications
Video Bandwidth DC to 100 MHz In/Out Impedance 75 ohms In/Out Signal Level 3 volt peak to peak Signal/Noise Ratio 75 dB/min Differential Gain 0.5% max Differential Phase 0.3º max Field Tilt 1% max Indicator Lights Pwr, Input 1, Input 2, Fault, Alarm Signal Connectors BNC Temperature Range -35º to +75ºC Power Requirements 11-24 VAC/DC @150 mA Physical Size (mm) 5.0”(127)L x 1.0” (25.4)W x 3.0”(7)D
All specifications are subject to change without prior notice.
Installation Instructions
The diagram below shows the typical installation of the RSW-1002 with VT-1001 and VR-1001 fiber optic video transmission units.
VT-1001
Camera
Camera
Typical Redundant Fiber Optic CCTV System
Upon loss of the primary video signal, the RSW-1002 will automatically switch the remaining secondary (backup) video signal to the output as well as activate the front panel alarm “Alm” indicator and ALM-1000 Alarm Sensing Unit if used.
Fiber Optic Cable
VT-1001
Fiber Optic Cable
VR-1001 ALM-1000
VR-1001
Power Terminal Block Connections
Pin Function
Alarm output for use with optional Alarm Sensing Unit
1
ALM-1000. No other connections should be made to this
terminal 2 +11 to 24 DC or AC Volts input 3 AC or DC return (Common to Housing)
Be certain to check all connections, settings and voltages before applying power
RSW-1002
Alarm
Contacts
Monitor
108515 Rev E
Mode Switch
Setting Function
Pri Forces Primary feed to common output
Auto mode;
If there is no signal on primary feed, but a signal
Auto
Sec Forces Secondary feed to common output
on the secondary feed, the secondary feed is connected to common output. Otherwise, Primary feed connects to common output.
Indicator Lights
Indicator Lights when
Pwr Proper power is present.
Alrm* One or both video input signals are not present
Pri A signal is present at Primary input
Sec A signal is present at Secondary input.
The loss of the signal at Input 1 (Primary) has
Fault
* Note that if the alarm “Alm” indicator is enabled the output for the optional ALM-1000 Alarm Sensing Unit will also be enabled.
occurred and the video signal at Input 2 (Backup) has been routed to the output.
5 Pin Control Terminal Block Connector Block
Pin Function
Relay contacts (2 Amp dry contact)
1 Normally Open Contact 2 Common Contact 3 Normally Closed Contact
External control of Mode (valid only when in Auto mode)
4 Ground to Force Primary output 5 Ground to Force Secondary output