Listo TH765-M, THA61-M, TH865-M, TH465-M User Manual

Page 1
TH Series Touch Screen USER MANUAL
TH465-M TH765-M TH865-M THA61-M
4.3 inch, TFT True Colour Display, 480x272 Pixels, 8MB Memory, 2 RS232/485 Serial Ports, 3 USB Ports
7 inch, TFT True Colour Display, 800x448 Pixels, 128MB Memory, 2 RS232/485 Serial Ports, 3 USB Ports
8 inch, TFT True Colour Display, 800x600 Pixels, 128MB Memory, 2 RS232/485 Serial Ports, 3 USB Ports
10.4 inch, TFT True Colour Display, 640x480 Pixels, 128MB Memory, 2 RS232/485 Serial Ports, 3 USB Ports
Doc Ref: LMAN018_R2V2
Page 2
TH series Touch Screen User Manual Page 2 of 80 LMAN018_R2V2
TH Series Touch Screen USER MANUAL
Index Page
Chapter 1 Summarize
1-1 Performancecharacteristics 4
1-1-1 Display 4 1-1-2 Control 5 1-1-3 Communication 5
1-2
Workflow 5
Chapter 2 General Specifications
2-1 TH465M 7 2-2
TH475‐M 8
2-3
TH485‐M 9
2-4
THA61‐M 10
Chapter 3 Hardware
3-1 Hardwarestructure 12 3-2
Dimensions 13
3-3
Installationandusingenvironment 14
Chapter 4 Interface and switch
4-1 Introduction 17 4-2
DIPswitch 18
4-3
COM1port 18
4-3-1 Download function 18 4-3-2 Forced download 20 4-3-3 Communication function 20
4-4
COM2port 22
4-5
USB‐Aport 24
4-6
USB‐Bport 25
Chapter 5 Touchwin software
5-1 Preparation 27 5-2 The construction of Touchwin 28
5-2-1 Screen 29 5-2-2 Project bar 29 5-2-2-1 File 30 5-2-2-2 Edit 35 5-2-2-3 View 35 5-2-2-4 Part 36 5-2-2-5 Tool 36 5-2-2-6 Window 37 5-2-2-7 Help 37 5-2-2-8 Screen 37
5-3 Tool bar 39
Chapter 6 Create a simple project
6-1 Buildanewproject 42 6-2 Makeasimpleproject 44 6-3 Simulateoffline 46 6-4 Simulateonline 47 6-5 Downloadingtheproject 48
Page 3
TH series Touch Screen User Manual Page 3 of 80 LMAN018_R2V2
Chapter 7 Application
7-1 Adjustthetoucharea 50 7-2 Photoapplication 52 7-3 Debuganddownload 55 7-4 Databackup 56
7-4-1 Data export 57 7-4-2 Import the CSV data 69
Chapter 8 TH series touchscreen interior objects 77
                                    
Page 4
TH series Touch Screen User Manual Page 4 of 80 LMAN018_R2V2
1 Summarize
Xinje new touch screen TH series are based on TP series products. It not only has the language, characters editing, data display, monitor and alarm functions but also has 65536 true color LCD which can bring you brand-new vision enjoyment. It has the advantage of large capability for data duplication and friendly user interface. It provides perfect humanized solution for industrial system, make it easy to control the system.
The function compare between TP and TH:
Series
Function compare
Colours
Font setting
3D pictur e librar y
Adju st the touc h area
Animation Password
Two ports communicat e-on independent ly
USB data downlo ad
USB data duplicate
-on
TP
256
TH
65536
   
1-1-1 Display
Various models: product size from 4.7’’ to 10.4’’. Rich colours: 65536 TFT true colour, support BMP, JPG format, display more lively. Adjust function for touch screen. Support multinational language: simple/traditional Chinese, English, Japanese, Korean.
Define the font as you like, support underline, italic, bold, shadow and other art words.
Large picture library, with preloading mode, no delay for screen motion.
1-1 Performance and characteristics
1-1 Performance and characteristics
1-2 Work flow
Page 5
TH series Touch Screen User Manual Page 5 of 80 LMAN018_R2V2
1-1-2 Control
Switch control, dynamic monitor and display data, bar map, real time trend map, time trend
map, XY trend map, discrete/continue column map, real time alarm, history alarm record…
User-defined data collection and saving function Set user’s authority, 9 levels password protection Simulate online/offline, upload/download data, configuration function USB port inside, connect flash disk to realize data duplication function, speed 480Mbps Special USB-B port for data download, make the data transfer faster User-defined animation track design
1-1-3 Communication
Two ports communication independently, can connect two different devices at the same time Drive the panel printer directly, economical and flexible Support free format communication, user edits the driver program
The work flow of using TH:
Note:
Please use TouchWin V2.C and later version to edit your TH project.
1-2 Work flow
Edit your project
Download project in TH
Do simulate offline Simulate the TH action in the software.
Do simulate online Connect the PC with TH, simulate the action in your PC
Install edit software TouchWin
Connect PC and TH, power on
Connect TH with other devices
Realize communication and data
Page 6
TH series Touch Screen User Manual Page 6 of 80 LMAN018_R2V2
2 General specifications
This chapter will introduce the specification of TH series touch screen. TH series touch screen contains TH465-M, TH765-M, TH856-M and THA61-M.
Series Types
TH
TH465-M TH765-M TH865-M THA61-M
 
2-1 TH465-M
2-2 TH565-M
2-3 TH665-M
2-4 THA61-M
Page 7
TH series Touch Screen User Manual Page 7 of 80 LMAN018_R2V2
2-1 TH465-M

Item
TH465-M
Electrical
Input voltage DC20-DC28V
Consumption current
130mA
Momentary power off allowance
Less than 10ms
Withstand voltage AC1000V-10mA 1 minute ( signal and time )
Insulated impedance
DC500V- about 10M ( signal and time )
Interface
COM1 Support RS-232/RS-485 COM2 Support RS-232/RS422/RS485 USB1 USB-A ( accord with USB2.0 ) USB2 USB-A ( accord with USB2.0 ) USB3 USB-B ( accord with USB2.0 )
Environment
Operation temperature
050
Reserve temperature
-20-60
Environment temperature
20-85% ( no condensation )
Withstand oscillation 10-25Hz ( X, Y, Z each direction 30 minutes
2G )
Anti-jamming Voltage noise: 1000Vp-p, pulse 1us, 1
minute
Surrounding air No corrosive gas
Protection construction
IP65
Screen specification
Type 65536 true colours Screen size 4.3 inch
Use life More than 50000 hours, 24 hours running
when surrounding temperature is 25
Resolution 80*272
Contrast Non-adjustable Character Chinese, English, Korean, Japanese… Character size Any size and font
Touch panel 4-wire resistance mode
Memory
Screen 8MB
Construction
Cooling method Natural air cooling Exterior dimension 150.0*100.0*41.0mm
Mounting dimension 144.0*94.0mm
Page 8
TH series Touch Screen User Manual Page 8 of 80 LMAN018_R2V2
Item
TH765-M
Electrical
Input voltage DC20-DC28V
Consumption current 250mA Momentary power off allowance
Less than 10ms
Withstand voltage AC1000V-10mA 1 minute ( signal and time ) Insulated impedance DC500V- about 10M ( signal and time )
Interface
COM1 Support RS-232/RS-485 COM2 Support RS-232/RS422/RS485 USB1 USB-A ( accord with USB2.0 ) USB2 USB-A ( accord with USB2.0 ) USB3 USB-B ( accord with USB2.0 )
Environment
Operation temperature
050
Reserve temperature
-20-60
Environment temperature
20-85% ( no condensation )
Withstand oscillation 10-25Hz ( X, Y, Z each direction 30 minutes 2G ) Anti-jamming Voltage noise: 1000Vp-p, pulse 1us, 1 minute Surrounding air No corrosive gas
Protection construction
IP65
Screen specification
Type 65536 true colors Screen size 7 inch
Use life More than 50000 hours, 24 hours running when
surrounding temperature is 25
Resolution 800*448
Contrast Non-adjustable Character Chinese, English, Korean, Japanese… Character size Any size and font
Touch panel 4-wire resistance mode
Memory
Screen 128MB
Construction
Cooling method Natural air cooling Exterior dimension 205.0*151.5*48.9mm
Mounting dimension 192.0*138.5mm
2-2 TH765-M
Page 9
TH series Touch Screen User Manual Page 9 of 80 LMAN018_R2V2
Item
TH865-M
Electrical
Input voltage DC20-DC28V
Consumption current 260mA Momentary power off allowance
Less than 10ms
Withstand voltage AC1000V-10mA 1 minute ( signal and time ) Insulated impedance DC500V- about 10M ( signal and time )
Interface
COM1 Support RS-232/RS-485 COM2 Support RS-232/RS422/RS485 USB1 USB-A ( accord with USB2.0 ) USB2 USB-A ( accord with USB2.0 ) USB3 USB-B ( accord with USB2.0 )
Environment
Operation temperature
050
Reserve temperature
-20-60
Environment temperature
20-85% ( no condensation )
Withstand oscillation 10-25Hz ( X, Y, Z each direction 30 minutes 2G ) Anti-jamming Voltage noise: 1000Vp-p, pulse 1us, 1 minute Surrounding air No corrosive gas
Protection construction
IP65
Screen specification
Type 65536 true colors Screen size 8 inch
Use life More than 50000 hours, 24 hours running when
surrounding temperature is 25
Resolution 800*600
Contrast Non-adjustable Character Chinese, English, Korean, Japanese… Character size Any size and font
Touch panel 4-wire resistance mode
Memory
Screen 128MB
Construction
Cooling method Natural air cooling Exterior dimension 224.4*170.8*45.5mm
Mounting dimension 211.4*157.8mm
2-3 TH865-M
Page 10
TH series Touch Screen User Manual Page 10 of 80 LMAN018_R2V2
Item
THA61-M
Electrical
Input voltage DC20-DC28V
Consumption current 630mA Momentary power off allowance
Less than 10ms
Withstand voltage AC1000V-10mA 1 minute ( signal and time ) Insulated impedance DC500V- about 10M ( signal and time )
Interface
COM1 Support RS-232/RS-485 COM2 Support RS-232/RS422/RS485 USB1 USB-A ( accord with USB2.0 ) USB2 USB-A ( accord with USB2.0 ) USB3 USB-B ( accord with USB2.0 )
Environment
Operation temperature
050
Reserve temperature
-20-60
Environment temperature
20-85% ( no condensation )
Withstand oscillation 10-25Hz ( X, Y, Z each direction 30 minutes 2G
) Anti-jamming Voltage noise: 1000Vp-p, pulse 1us, 1 minute Surrounding air No corrosive gas
Protection construction
IP65
Screen specification
Type 65536 true colors Screen size 10.4 inch
Use life More than 50000 hours, 24 hours running when
surrounding temperature is 25 Resolution 640*480
Contrast Non-adjustable Character Chinese, English, Korean, Japanese… Character size Any size and font
Touch panel 4-wire resistance mode
Memory
Screen 128MB
Construction
Cooling method Natural air cooling Exterior dimension 311.0*234.0*48.0mm
Mounting dimension 302.0*225.0mm
2-4 THA61-M
Page 11
TH series Touch Screen User Manual Page 11 of 80 LMAN018_R2V2
3 Hardware
3-1 Hardware structure
3-2 Dimensions
3-2 Installation and using environment
Page 12
TH series Touch Screen User Manual Page 12 of 80 LMAN018_R2V2
The hardware structure of TH series touch screen includes front and back side. Take TH465-M as an example to explain the structure.
Touch area
Power LED
USB-A port
Label
Power Plug
DIP switch
COM1 port
COM2 port
USB-A port
USB-B port
3-1 Hardware structure
Page 13
TH series Touch Screen User Manual Page 13 of 80 LMAN018_R2V2
1. TH465-M exterior dimension:150.0mm×100.0mm×41.0mm, mounting dimension:
144.0mm×94.0mm.
2. TH765-M exterior dimension:205.0mm×151.5mm×48.9mm, mounting dimension:
192.0mm×138.5mm.
3-2 Dimensions
24V 0V FG
1234
92. 0
142. 0
41. 0
150. 0
100. 0
COM1COM2
144.
0
94. 0
48. 9
12. 0
136. 5
190. 0
1234
24V0V FG
1234
COM1COM2
205. 0
151. 5
138.
5
192. 0
Page 14
TH series Touch Screen User Manual Page 14 of 80 LMAN018_R2V2
3. TH865-M exterior dimension: 224.4mm×170.8mm×45.5mm, mounting dimension:
211.4mm×157.8mm.
4. THA61-M exterior dimension: 311.0mm×234.0mm×48.0mm, mounting dimension:
302.0mm×225.0mm.
302. 0
225. 0
+24V 0V FG
311. 0
234. 0
48. 0
223. 0
43. 1
300. 0
1234
+24V 0V FG
COM1COM2
211. 4
157. 8
1234
1234
Download
PLC
24V0V FG
224. 4
170. 8
38. 0
45. 5
155. 8
209. 4
Page 15
TH series Touch Screen User Manual Page 15 of 80 LMAN018_R2V2
Installation requirements:
1. TH has four ferric mounting racks when out of factory, there are two square holes on the up, down side of TH, use mounting rack to fix the TH with control cabinet. In order to avoid TH temperature too high after long time working, please keep 10cm space on the up/down and 5cm on the left/right side of the TH when installing.
2. Installation steps: a) Refer to the dimension in the former chapter to open a rectangle mounting hole in the control cabinet
b) Add airproof circles in the airproof slot when installing c) Insert the bottom of TH into the mounting hole of control cabinet d) Insert the install rack into the fix hole of TH then tighten the screw
e) Connect TH and PLC with communication cable
Note:
The communication cable can be offered by the supplier or made by user according to the connection map, input +24V DC power to start working
3. Environment
Please use TH series touch screen indoors. Do not use TH in below environments: Inflammable gas, steam, dust, fast vary temperature, high humidity (it may cause moisture inside TH).
4. Power supply requirements:
TH series touch screen use DC +24V power supply only. The permitted voltage range is 20V~28V. The connection is as below:
Besides, if connect high voltage or AC power supply with TH, the TH may be damaged and cause electric shock to human body.
Note:
If use the DC +24V output of PLC to drive the TH, make sure the PLC has enough current to drive the TH.
Install panel
3-3 Installation and using environment
+24V
0 V
+ DC-
Page 16
TH series Touch Screen User Manual Page 16 of 80 LMAN018_R2V2
5. Maintenance and cleaning
Maintenance:
Please do not open the back cover by yourself. Please do not analyse or change TH by yourself Please cut off all the power supply while observing the TH. Please do not touch terminals after power on, otherwise it may cause electric shock. Do not hot plug the cable or pull the cable when communicating, it may destroy the cable. Please periodic check installation and screws to avoid falling off. Please use TH series touch screen in the certain conditions according to instructions. Keep the cleanness of touch area, in order to keep touch sensitivity.
Cleaning
Please use clean cloths with little detergent or alcohol to clean the screen. Neutral detergent, without acid, alkali is recommended. Keep the TH away from thrill or strong corrosive gas Never use spray detergent. Avoid damage to the screen, please do not touch the screen too hard while wiping.
Disposal
Please dispose the TH as industry waste.
Caution
Caution
Caution
Page 17
TH series Touch Screen User Manual Page 17 of 80 LMAN018_R2V2
4 Interface and switch
TH series touch screen has 1 group of DIP switch and 5 communication ports.
1: DIP switch 4: USB-A port1 2: COM1 port 5: USB-A port2 3:COM2 port 6: USB-B port3
4-1 Introduction
4-1 Introduction
4-2 Dip switch
4-3 COM1 port
4-4 COM2 port
12 3
4
4-5 USB-A port
4-6 USB-B port
Page 18
TH series Touch Screen User Manual Page 18 of 80 LMAN018_R2V2
TH has one group of DIP switch at the back side; they can set the function of COM1 port.
Switch Switch1 Switch2 Switch3 Switch4 Function
State
ON OFF OFF OFF Undefined
OFF ON OFF OFF Forced download mode of COM1
OFF OFF ON OFF Adjust mode of touch area
OFF OFF OFF ON
Interior check mode ( not recommend to use)
4-3-1 Download function
TH series touch screen COM1 port has these functions:
Communication function: connect with PLC, printer, frequency inverter, used as
communication port.
Download function: connect with PC, used to download data and screens.
COM1 port pins definition
123
4
5
6
7
89
The following terms should be done when using download function:
1. Turn on switch 2 in DIP switch group to make the COM1 in download mode.
2. Please use the cable provided by Xinje company.
4-2 Dip switch
4-3 COM1 port
Pin Name Meaning
1 NC Unused terminal 2 RXD RS232 receive 3 TXD RS232 send 4 A RS485 + signal 5 GND Signal ground 6 NC Unused terminal 7 B RS485 – signal 8 NC Unused terminal 9 NC Unused terminal
Page 19
TH series Touch Screen User Manual Page 19 of 80 LMAN018_R2V2
Step:
Make sure your PC has serial port or USB port ( use USB converter tool), connect it with COM1, then
click
in the software to download data. The pins definition is shown as below:
PC serial port TH COM1 port
1. Turn on switch2 when TH power supply is cut off
2. Power on TH, connect TH with PC via Xinje download cable to download project
3. After the download process is over, cut off the power of TH, then turn off the switch2
4. Power on the TH again, the project will run normally
PC
TH
Xinje download cable
Page 20
TH series Touch Screen User Manual Page 20 of 80 LMAN018_R2V2
4-3-2 Forced download
1234
ON
OF
F
Note:
About the TH download details, please refer to the chapter “build a simple project---project download”.
4-3-3 Communication function
COM1 port has strong communication functions. The default mode of COM1 is communication mode.
The COM1 default mode is Communication mode, you can realize the communication function by
setting the correct communication parameters and device
After the download is completed. if the TH cannot display the screen normally, you can try
the forced download mode to update the system.
Step:
1. Cut the power of TH, turn on switch2
2. Power on the TH, connect the cable then download the project
3. After the download is completed, turn off switch2 then power on the TH again.
Send data
Response
TH
COM1 port
Frequency inverter
PLC
Other
Page 21
TH series Touch Screen User Manual Page 21 of 80 LMAN018_R2V2
COM1 port communication parameter COM1 port communication device
Page 22
TH series Touch Screen User Manual Page 22 of 80 LMAN018_R2V2
COM2 port has below functions:
1. Communicate with industry devices, such as PLC, inverter, meters…
COM2 port pins definition
2. Communicate with PLC
TH can communicates with most mainstream PLC.
Select the correct PLC type in the list and set the communication parameters:
4-4 COM2 port
Pins Name Meaning
1 TD+ RS422 send + 2 RXD RS232 receive 3 TXD RS232 send 4 A RS485 + 5 GND Signal ground 6 TD- RS422 send ­7 B RS485 ­8 RDD- RS422 receive ­9 RDD+ RS422 receive +
1
2
345
67
8
9
Data
transfer
OmronPLC…
COM2
TH series
Panasonic
SIEMENS PLC
Page 23
TH series Touch Screen User Manual Page 23 of 80 LMAN018_R2V2
Note:
Please refer to “TP connect with PLC” for the details of TH communicate with PLC.
3. Communicate with frequency inverter
TH can communicate with various brands of frequency inverters. For the brands which are not in the list, user can select Modbus protocol or user-defined protocol.
Note:
Please refer to “TP series touch screen application examples” for the details of TH communicating with frequency inverter.
4. Communicate with meters About the communication between TH and meters, users can select user-defined protocol or Modbus protocol.
Note:
Please refer to “TP series touch screen application examples” for the details of TH communicating with meters.
COM2
TH
Mitsubishi FR series inverter
Inovance MD series inverter
BoschRexrothIndracontrol L40
Page 24
TH series Touch Screen User Manual Page 24 of 80 LMAN018_R2V2
TH has two USB-A ports ( accord with USB2.0 ). The functions are show as below:
1. Duplicate data, data import and export, transmission speed can be 480Mbps.
USB-A port definition
2. Connect U-disk and other USB port devices
USB‐A
USBcable
THfrontside
USBmobile harddisk
USB-
A
USB-A por
t
4-5 USB-A port
Pins Name Meaning
1 +5V +5V voltage signal 2 DATA+ Data signal + 3 DATA- Data signal ­4 -5V -5V voltage signal
Page 25
TH series Touch Screen User Manual Page 25 of 80 LMAN018_R2V2
TH has one USB-B port ( accord with USB2.0 ), located in the back side of TH, the functions are shown as below:
To download the data, the speed can up to 480Mbps.
USB-B port definition:
Please use the USB cable sold in the market when connecting PC with USB-B port, then click in the software to download your project in TH.
USBcable
THbackside
4-6 USB-B port
Pins Name Meaning
1 +5V +5V voltage signal 2 DATA+ Data signal + 3 DATA- Data signal ­4 GND Ground signal
PC
Page 26
TH series Touch Screen User Manual Page 26 of 80 LMAN018_R2V2
5 Touchwin software
5-1 Preparation
5-2 The construction of Touchwin
5-2 Tool Bar
Page 27
TH series Touch Screen User Manual Page 27 of 80 LMAN018_R2V2
1. Software version: V2.C and later versions.
2. Software source: visit Xinje website www.xinje.com
to obtain the software or get from the products
CD.
3. OS requirements: Windows98/2000/XP/ME
4. Install steps:
5-1 Title
Click “next” until show below window
Enter the information in the space: serial number is
ThingetTouchWin.
Click tousethesoftware.
Click“next”tofinishyourinstallation.
Open setup.exe
Page 28
TH series Touch Screen User Manual Page 28 of 80 LMAN018_R2V2
5-2-1 Screen
Double click the Touchwin software, build a new project, then you can see the following screen:
Project bar: build, delete, copy, cut operation of the screen and window Screen edit area: make the project in this area Menu: it includes file, edit, view, tool, part, window and help. Element bar: it includes standard, part, panel, operate, status, zoom, draw and align. Status bar: it includes HMI type, PLC port device and download port device.
5-2 The construction of Touchwin
Projectbar Screeneditarea Menu Toolbar
Statusbar
Page 29
TH series Touch Screen User Manual Page 29 of 80 LMAN018_R2V2
5-2-2 Project bar
Project bar contains the operation of screen and window.
1. Screen operation
Build a new screen
Method 1: click
in the element bar.
Method 2: right click the screen in the project bar, then click insert.
It shows the following window:
Screen cut, copy and delete
Select the screen in the project bar, right click and choose cut, copy or delete.
Window operation
1. Right-click the window/insert in the project bar. Input the window ID, name and message.
2.
ID: The number of the screen
Name: The name of the screen Message: The description of the
screen
Click
to modify the screen
property.
Page 30
TH series Touch Screen User Manual Page 30 of 80 LMAN018_R2V2
3. window cut, copy, delete select the window in the project bar, right click to select cut, copy or delete window.
5-2-2-1 File
The file menu is shown as the following:
1. New: Build a new file
2. Open: Open a file
3. Close: Close a file
4. Save: Save a file
5. Save as: Save a file as another name and path
6. Download:
to download project into TH
7. Run-online: Connect PLC and TH, Simulate online
in
TH software.
8. Run-offline: Simulate offline
, simulate the touch
screen action in the software.
Page 31
TH series Touch Screen User Manual Page 31 of 80 LMAN018_R2V2
PFW set:
Step1: Set the PFW register range, click “Add” to add the register in the list.
Change the range then click “Modify”, it will show below message, click ‘Yes” to confirm the modify.
Step2: Set the value in the range Double click the PFW range, it will show data setting window:
Step3: Download the project into TH.
Note:
PFW0~PFW256 are occupied by the TH system, please select register start from PFW257.
1. Display number can select decimal or hex.
2. Set FF: set all the data to FFFF.
3. Reset 0: set all the data to 0.
Page 32
TH series Touch Screen User Manual Page 32 of 80 LMAN018_R2V2
Setting:
Para tab:
Screen:
Select the start screen number when TH is power on. Password: there are 9 levels password, the level 9 password has the highest priority. The higher level password can used to all the elements of lower level password. The password is used to protect the element or screen, when input the correct password, the button or screen can be used.
Screen save:
To protect the LCD. After certain time, the background light will be off or jump to certain screen.
Alternation tab:
1. Change screen control:
2. Change the screen ID according to the value of the register.
3. Report current screen ID:
4. The current screen ID will show in the register.
5. For example, change screen control D0=1, TH displays No.1 screen, report current screen ID D1=1.
Page 33
TH series Touch Screen User Manual Page 33 of 80 LMAN018_R2V2
Clock tab:
Panel tab:
Device tab:
1. Export the current time to the register.
2. For example, object D0, so the real time will save in D0~D5. D0=year, D1=month, D2=day, D3=hour, D4=minute, D5=second.
Please note the export time is hex number.
1. The TH type you are using now.
2. Set parameter:
3. Modify the quantity of PFW and PSW registers.
1. Set the PFW register quantity
2. Set the PSB register quantity
3. VisPSW Num: the PSW quantity in data input, data display area.
4. PriPSW Num: the PSW quantity in history trend map, real time trend map area.
5. Cache Num: PFW register quantity
1. Single, host net, slave net: TH communication mode.
2. PLC port: TH PLC port connects device type,
change the communication parameters by
3. Download port: TH download port connects device type, change the communication
parameters by
Page 34
TH series Touch Screen User Manual Page 34 of 80 LMAN018_R2V2
Font:
Project tab:
Build SCADA
It realizes the SCADA function in windows. Build the SCADA file, and double click it to simulate online.
Note:
Please refer to the chapter “ make a project/simulate online “.
Last
The latest files operated by the user.
Exit
Quit the Touchwin software.
Set the font of the letter in the screen.
Record the project name, author and remark.
Page 35
TH series Touch Screen User Manual Page 35 of 80 LMAN018_R2V2
5-2-2-2 Edit
1. Cut, copy, paste, undo
These operations are used to the elements in the screen.
2. Replace
3. Public unit
Select one element in the screen, click public unit, this element will be added in all the screens.
4. Private unit
After select one element as public unit, click private unit to delete this element in other screens.
5-2-3-3 View
Cut, copy, paste, undo
Public unit, private unit
1. Replace register or coil
2. Find what: the object you want to replace
3. Replace with: the new object
4. Object Num: the quantity you want to replace
5. Replace in: replace the object in current screen or all the screens.
1. Display all the tool bars. Advance and advance2 is grey colour.
2. Only when open the advance function of software, these items can be used.
3. All the items with tick are displayed in the software menu.
Page 36
TH series Touch Screen User Manual Page 36 of 80 LMAN018_R2V2
5-2-2-4 Part
5-2-2-5 Tool
Option:
The “part” is used to edit the TH project, it is the same as the tool bar in the software.
Tool menu is the same as the following tool bar.
Grid size:
1. Move Grid: set the min pixel when moving the element.
2. Grid radio: the grid density, the smaller the value is, the denser the grid is.
3. Auto save: auto save the project at the time you set.
4. Download: select the project download com port.
5. Download all: when you want to upload the data, please select this item before you download the data into TH.
6.Displaymousecursor:displaythe mouseconnectedtoTHUSBport.
Page 37
TH series Touch Screen User Manual Page 37 of 80 LMAN018_R2V2
5-2-2-6 Window
5-2-2-7 Help
5-2-2-8 Screen
1. New: build a new window
2. Cascade: show all of the window in cascade mode.
3. Tile: show all the window in tiled mode.
4. Arrange icon: arrange all the icons again.
ShowtheTouchwinsoftwareversionand copyright.
1.Zoomin,zoomoutthescreen:
zoomout, zoomin
showthegridinthescreen.
Page 38
TH series Touch Screen User Manual Page 38 of 80 LMAN018_R2V2
5-2-3 Tool bar
Icon Name Function
New Build a new project Open Open the file Save Save the file Cut Cut the element
Copy Copy the element
Paste Paste the element
Undo Undo the operation
Help Check the software version information
Text Input static text
Dynamic text
Display the text according to the value of register, support 16 texts, set register value as 0~15
Variation text
Display the text according to the value of register, set register value as user need
Lamp Display the ON/OFF state of switch
Button ON/OFF the bit element
Lamp button Combine the function of lamp and button
Screen jump Jump to object screen
Digital display Display the register value
Alarm display
Set the upper/lower limit of register value, when exceeding the range, twinkle display
Text display Display characters in multi-registers
Digital input Input the data in the register
Text input Input characters in the register
Set data Set data and used in arithmetic
Digital keyboard Digital input keyboard
ASCII keyboard Character input keyboard
User input One input button of keyboard
Bar Display the register value in bar picture
Dynamic map
Display the map according to the register value, support 16 maps, the register value is 0~15
Call window
Call window according to the value in the coil or register
Window button Control the open, close of the window
Download recipe Download the recipe into object device
Upload recipe Upload the recipe into TH register
Function button Realize multi-functions with this button
Function field
Similar to function button, but the trigger condition is different.
Discrete column map Display the data in discrete column map
Continue column map Display the data in continue column map
Line Draw lines
Page 39
TH series Touch Screen User Manual Page 39 of 80 LMAN018_R2V2
Arc Draw arc
Rectangle Draw rectangle
Ellipse Draw ellipse
Fold/polygon Draw fold and polygon
Polygon block Similar to container
Frame Draw 3D rectangle
Map Add jpg or bmp format pictures
Move animation make the movement animation of object
Rotate animation Switch the picture
Material library The picture library
Date Display the date
Clock Display the time
Buzzer Control the buzzer by the coil
LCD light control Control the background light by the coil
Scale Display the value in scale
Instrument Display the value in the meter
Valve Simulate the state of valve
Pipe Simulate the liquid state in the pipe
Pump Simulate the pump running
Auto wind Simulate the auto wind
Motor Simulate the motor running
Retort Simulate the retort running
Inverter alarm information
Display the inverter alarm information
Scroll text Display the text in scroll mode
Real time map Display the current value in curve
History data map Display the current and history value in curve
XY curve Display two curve in X, Y direction
XY curve Ex Display the value in line, point and line-point.
Time trend control Display value in certain time space
Event button
Use with event, curve, realize flip, confirm and clear operation
Alarm list Show the inverter alarm information in the list
Display real time event
Display real time alarm information, when the alarm is free, the event will be deleted automatically
Display history event
Display many alarm information and event happen time
Common grid control Display a group of register in the table
Data grid control
Display a group of register in the table, support time information table
Sample save
To collect the object data, no limit for the sample quantity and time, save the data in TH registers
Sample export
Save the data in TH register and export to object device as CSV format file
Page 40
TH series Touch Screen User Manual Page 40 of 80 LMAN018_R2V2
Align left Align left the objects
Align centre Align centre the objects
Align right Align right the objects
Align top Align top the objects
Align middle Align middle the objects
Align bottom Align bottom the objects
Zoom out Zoom out the screen
Zoom percent Zoom percent
Zoom in Zoom in the screen
Grid Display grid in the screen
State change Switch button state display
Dynamic picture state selection
Switch dynamic picture state display
Public unit Use the unit in all the screens
Private unit Use the unit in appointed screen
New Build a new screen
Property Screen name, author, remark…
Delete Delete the current screen
Simulate offline Simulate the project in the TH
Simulate online Connect PLC and TH, simulate the project in TH online
Download Download the project in the TH
Upload Upload the project from TH to PC
Debug download Debug download
Page 41
TH series Touch Screen User Manual Page 41 of 80 LMAN018_R2V2
6 Create a simple project
In this chapter, make a switch to control the PLC output, in order to explain how to make TH project.
Note:
Please make sure of the TH type and communication device type. It is important for the project download and device communication.
6-1 Build a new project
6-2 Make a simple project
6-3 Simulate offline
6-4 Simulate online
6-5 Download the project
Page 42
TH series Touch Screen User Manual Page 42 of 80 LMAN018_R2V2
1. Open the Touchwin version 2.C.2 or above software.
2. Click File/New or
to build a new project.
3. Select the correct TH type and com port device type
TH type COM port device type
4. Set the com port device communication parameters according to PLC port device
5. When download port (COM1) is not used as communication port, please select unuse download
port.
When use COM1 as com port, please select communication device.
6-1 Build a new Project
Page 43
TH series Touch Screen User Manual Page 43 of 80 LMAN018_R2V2
6. Finish the building process.
7. Click
to save the project in the PC.
Page 44
TH series Touch Screen User Manual Page 44 of 80 LMAN018_R2V2
Make a button on the screen, to control the Y0 output of Xinje XC series PLC.
1. Make a button:
Click
, put the button on the screen. Change the object to Y0.
Select operate tab, change the button operate to reverse.
Select button tab, change the text to reverse
PLCoutput
La
But
La
But
TH
PLCCOM
Y
Y
PLC
Set
Set
Y
Y
6-2 Make a simple project
Page 45
TH series Touch Screen User Manual Page 45 of 80 LMAN018_R2V2
Select the colour tab, change the button colours
2. Make the lamp
Click , put it on the screen, change the object to Y0.
Select the lamp tab, change the aspect of the lamp.
Select the twinkle tab, change the lamp state to stop twinkle.
Page 46
TH series Touch Screen User Manual Page 46 of 80 LMAN018_R2V2
Colour and position tab are similar to the button.
Do not have to download the project into the TH, you can simulate the project in the touchwin software. It can save debug time and easy to edit.
1. Click
to enter simulate offline screen.
2. Click the reverse button to see the ON/OFF switching of the lamp.
Turn off the reverse button Turn on the reverse button
Thus, the simulate operation is finished.
6-4 Simulate online
6-3 Simulate offline
Page 47
TH series Touch Screen User Manual Page 47 of 80 LMAN018_R2V2
By connecting the PLC and PC, it can read the data from PLC, simulate the operate of TH in Touchwin software. Do not have to download the project into TH, you can control the PLC in your PC. Make sure the connection is correct between PLC and PC, the com port setting is right.
Note:
Only Xinje PLC support the simulate online function with TH.
1. Connect Xinje PLC with the PC via serial port.
2. Click the
to enter simulate online. It will show below message:
This means that the simulate online is not registered, you can only use it for 2 hours. If you want to use it for longer, please contact Xinje company to get register number.
3. Click ok to enter simulate online screen. Right click the screen to show below menu:
Log: log on time and history record About: the version information of autowin Com port: the serial port number of your PC which is connected with PLC. Register: register to get user right. Exit: exit the autowin.
If showing the following message, it means the connection between PLC and PC is not good, or the serial port number is wrong.
In this example, we use TH PLC port and PC serial com port3, so select PLC port com 3.
Page 48
TH series Touch Screen User Manual Page 48 of 80 LMAN018_R2V2
1. Click the button to see the lamp is ON/OFF.
Turn off the reverse button turn on the reverse button
Upon clicking the reverse button, the PLC output Y0 will switch ON/OFF at the same time.
There are two modes to download the project into the TH:
1. USB port and USB cable
USB port downloading:
Connect TH USB-B port and PC with USB cable, power on the TH, click
to download the
project.
2. COM1 port and Xinje special cable
COM1 port downloading
Change COM1 to download mode, please refer to chapter 4.3, power on the TH, click
to
download the project.
6-5 Downloading the project
Page 49
TH series Touch Screen User Manual Page 49 of 80 LMAN018_R2V2
7 Application
7-1 Adjust the touch area
7-2 Photo application
7-3 Debug and download
7-4 Data backup (based on Touchwin V2.C.3)
Page 50
TH series Touch Screen User Manual Page 50 of 80 LMAN018_R2V2
The touch area adjustment function can make the component touch more precise.
The adjustment steps:
Step 1: Turn on the DIP switch 3, then power on the TH again, it will show the following screen:
Step2: After clicking the cross centre, the adjust cross will jump to the second position. Keep on click the cross until the cross jump to the last position 5.
Calibrate the touch panel
Repeat as the target moves around the screen
Adjust cross
7-1 Adjust the touch screen
Calibrate the touch panel
Repeat as the target moves around the screen
1
2
3
4
5
OF
F
ON
2134
Turn on switch 3
Click the centre of the adjust cross
Page 51
TH series Touch Screen User Manual Page 51 of 80 LMAN018_R2V2
Step 3: Please see the detailed motion:
Step 4: When finished the adjustment, the result is as the following;
Note:
If the adjustment process is end, please turn off the power of TH, then turn off the DIP switch 3, then turn on the power again. Now you can use TH normally.
A
djustment process is failed. Please do
again.
Calibrate the touch panel
Repeat as the target moves around the screen
Calibrate the touch panel
Repeat as the target moves around the screen
Calibrate the touch panel
Repeat as the target moves around the screen
Calibrate the touch panel
Repeat as the target moves around the screen
Calibrate the touch panel
Repeat as the target moves around the screen
1. Click the centre of the cross
2. Click the centre of the cross on the top left
3. Click the centre of the cross on the left bottom
4. Click the centre of the cross on the right bottom
5. Click the centre of the cross on the top right to finish the adjust
Adjustment process is end.
Repeat as the target moves around the screen
Calibrate the touch panel
Repeat as the target moves around the screen
Calibrate the touch panel
Page 52
TH series Touch Screen User Manual Page 52 of 80 LMAN018_R2V2
TH series LCD are 65536 true colours, it can make your photo display more vividly. This example will make the photo moving in parallel.
Step1: Select the photo
Click
button in the tool bar to open the material library:
Select the photo you want, and click “open”. The photo will be added on the screen.
Step2: Design the motion track
Click the
button in the tool bar, drag your mouse to draw the motion track, double click the
mouse to finish the drawing. Please see the drawing:
7-2 Photo application
Page 53
TH series Touch Screen User Manual Page 53 of 80 LMAN018_R2V2
Step3: Combine the photo with the motion track
Drag your mouse to select the photo and the motion track, then right click the mouse, select “group”.
Step4: Simulate offline
Click
to simulate offline your project. You can see the photo motion track.
Step5:
Change the animation property Right-click the photo and select “animal prop”
Page 54
TH series Touch Screen User Manual Page 54 of 80 LMAN018_R2V2
The animation property includes coordinate and control.
1. Coordinate
X: the position on X axis Y: the position on Y axis Escape time: the time that the photo moves from (X1,Y1) to (X2,Y2) Key point X,Y: the coordinate of every motion position
You can click the X, Y position and the escape time in the list and modify them.
2. Control
Enable: control the animation by bit signal. When the rising edge of the signal is coming, the
animation will be activated.
Reset: control the end of the animation by bit signal. When the rising edge of the signal is
coming, the animation will end.
Repeat: repeat the motion of the animation.
Page 55
TH series Touch Screen User Manual Page 55 of 80 LMAN018_R2V2
TH series touch screen support debug download function. This function can be used when you are debugging your project in order to save your time.
Compared with normal download function, this function has the following advantages:
1. This function only can be used when debugging the project.
2. The data transfer speed is faster than normal download, save time and cost.
Click
button in the tool bar to debug download the project into your TH.
7-3 Debug and download
Page 56
TH series Touch Screen User Manual Page 56 of 80 LMAN018_R2V2
Data backup includes the following contents:
1. Data collection and export, store the data of TH series HMI into USB device or SD card, produce
CSV data base file.
2. Import CSV data, transfer the data of USB device or SD card to TH series HMI.
About CSV file:
The CSV file is based on Excel, the format is as the following:
To build CSV file
Open Microsoft Excel, input the data as the up format, then save as .CSV file.
Temperature Pressure Hydraulic
pressure
D
ate
Ti
me
30 35 40 2
009­8-10
12:
10:10
Data
Date Time
Data
7-4 Data backup
Title
Page 57
TH series Touch Screen User Manual Page 57 of 80 LMAN018_R2V2
7-4-1 Data export
Export the data from TH to other device. Step1:
Click function button
or function field , select “export CSV data” and add it.
When using function button, please select “pressing” or “releasing” as the trigger condition.
When using function field, please select the trigger condition as you need.
Page 58
TH series Touch Screen User Manual Page 58 of 80 LMAN018_R2V2
Step 2: Double click “export CSV data”, it shows the following window: This window includes destination, import, save and date time tab.
1. Destination tab
Lengt h Wi dt h Hei ght Qty
20 30 40 12 32 41 37 13
Fix name file
Lengt h Width Height Qty
20 30 40 12
Lengt h Width Height Qty
32413
71
3
Fix name and re-export title file
Name add automatic: It exports a new file when collect the data each time. The new file name will increase automatically. For example, file 1 is TH001.csv, file 2 will be TH002.csv.
Please see the following picture:
Add number after name: add the number after the file name. For example, input 001
,
the file name is TH001.csv.
Dynamic set: set the number in D register. For example, If D0=20, the file name is TH020, D0=23, the file name is TH023.
Device ID: set the object device number which you want to export data, “dynamic set” can connect the D register with the device ID.
Path/File: the name of the CSV file
Fix name: the data collected each time will be saved in the same file.
Re-export title: export the title when collect the data each time Please see the following examples.
Page 59
TH series Touch Screen User Manual Page 59 of 80 LMAN018_R2V2
When “add number after name” and “dynamic set” are both selected, “dynamic set” has priority.
Named by date: the file name is added the date. When exporting the data several times at the same day, it will add the data title in the file automatically.
For example:
2. Data tab
3. Save tab
Export the data the first time on 8/18/2009
Lengt h Width Height Qty
20 30 40 12
Lengt h Width Height Qty
32413
71
3
Register capacity: import register quantity
Register mode: Loop: use with “real trend map”, “history data map”, “time trend control”, “sample save”… Line: export the data in the registers to CSV file. It is used to the recipe and data arrays.
Add, delete, move up, move down: Add the data titles, select the export data format and type.
Save the data in touch screen internal registers.
Export the data the second time on 8/18/2009
Page 60
TH series Touch Screen User Manual Page 60 of 80 LMAN018_R2V2
Process:
4. Control tab
This tab is used to control the export.
Execute status: To show if it is in exporting state via bit state. If the bit is ON, TH is exporting data. Execute result: Show the export result state via the register state.
export failed export target device does not exist the memory is not enough file path error reading / writing file failed
Execute process: Show the exporting process via register, 100 means the exporting process is succeed.
5. Date time
EXAMPLE: This chapter will introduce the data export examples in loop and line mode.
<A> Data export in loop mode
Purpose: collect the data via history data map, export the data to moveable device and save as CSV file.
Please see the whole process:
To add the date in the CSV file.
Please select the data format and time format in the pull down menu.
Produce data source
Data collection
Data export
Export the data
Collect data by history data map
PSW300 value increase 10 every 1 second, use function field to realize it.
Save the data in the registers start from PSW400
Produce CSV file
Collect object is PSW300
Page 61
TH series Touch Screen User Manual Page 61 of 80 LMAN018_R2V2
Next, we will introduce the each process:
1. Produce the data source: PSW300=PSW300+10 every 1 second:
Open the Touchwin software, click
Time
1. Collect data in loop mode
2. Data source: PSW300
3. Save object: registers start from PSW400
Data export to the registers start from PSW400
Produce CSV format file
Value
Select time: 1 second
History data map
Function filed
1. Data change every 1 second PSW300=PSW300+10
2. PSW data change process: 1 second:PSW300=0; 2 second: PSW300=10 3 second:PSW300=20; 4 second:PSW300=30
Page 62
TH series Touch Screen User Manual Page 62 of 80 LMAN018_R2V2
Note:
Please see the TP touch screen manual for this content.
2. Data collect: use history data map to collect the data every 1 second, use PSB300 to control if it is
need to collect.
Click
,add it in the screen, change the “trend source” tab.
Next, change the display tab: page data is 5, control is PSB300.
Add the arithmetic PSW300=PSW300+10
Page 63
TH series Touch Screen User Manual Page 63 of 80 LMAN018_R2V2
Change the save tab: save the data in the registers start from PSW400.
Add a button, to control the stop and start of the collection process. The button is related to PSB300.
3. Data export
Realize the data export function by function button. Click
in the tool bar.
Add it on the screen, set the button as the following:
PSW300+10every second
PSB300, to control the ON/OFF of data collection
Page data:5, show 5 numbers each screen
Total data:10, it can collect 2 screens data
Pick period: 1 second, collect the data every 1 second.
Control:PSB300, control the ON/OFF of the data collection by PSB300
Page 64
TH series Touch Screen User Manual Page 64 of 80 LMAN018_R2V2
Double click the “export CSV file” to continue the setting:
Data tab
Device ID: 1, there is one U disk device.
Path/File: name the file to SJDC.csv, re­export the title.
Register capacity: 10
Register mode: loop, to correspond to the history trend map
Format: decimal
Page 65
TH series Touch Screen User Manual Page 65 of 80 LMAN018_R2V2
Save tab
Date time tab
Now the data export has been done.
Via the
simulate offline, you can monitor
the data change and operate the button.
The operation steps: Step 1: Make sure the TH is connected to object device. Step 2: Click ON/OFF button to start the data collection in history data map Step 3: Click the data export button, the U disk device LED starts to flickering, it means the CSV file is being produced, if the LED ends flicker, the export process has been finished.
The CSV data is shown as below:
Turn on the button to start the history data map
Click the button to export the data into U disk
Save the data in PSW400
Date time: export the date and time to the .csv file.
Page 66
TH series Touch Screen User Manual Page 66 of 80 LMAN018_R2V2
<B> Data export in line mode
In industry system, HMI is seemed as control and monitor terminal. It can be used to set all kinds of parameters directly. In order to check the history data, use data export function to complete the data management.
Example: Using data export function to complete the parameters recording. Purpose: realize parameters setting by data input button, and data export by data export button. The process is shown as below:
Next, we will introduce how to make the project in two parts:
Part 1: Input the parameters
Put the data input button
on the screen, change the address as the following:
PSW500 PSW501 PSW502 PSW503 PSW504
Note:
About the data input button, please refer to TP series HMI manual.
Part 2: about data export button
Click
function button, then set as the following:
Realize by data input button
Data input 4
Data input 5
Data input 1
PSW500
Data input 2
PSW501
Data input 3
PSW502
PSW503
PSW504
Data export
Save in CSV format file
Set the head address to PSW500.
Realize by function button/export CSV data
Page 67
TH series Touch Screen User Manual Page 67 of 80 LMAN018_R2V2
Each group of parameters includes 5 values, export 1 group parameter each time, so the register capacity is 1.
Register mode is line.
Add the title, make it correspond to the parameters.
Double click the export CSV data to change the parameters: Destination tab:
Data tab:
Device ID: 1 is the U disk number
Change the file name to SJDX.csv, export the data to this file.
Page 68
TH series Touch Screen User Manual Page 68 of 80 LMAN018_R2V2
Excel file: SJDX.csv
Save tab:
Example: It has not referred to date and time, so do not have to set them. The screen has been done, please see the following picture:
Run the project, and you will see the following result:
Set the export object to PSW500, make it the same as the data input button address.
Data input
Data export
Page 69
TH series Touch Screen User Manual Page 69 of 80 LMAN018_R2V2
Device ID: the device number of import device
Dynamic set: set the device ID in D register. Import control: control the import process by M coil, when M is ON, the import process starts.
Path/File: the CSV file name
Fix name: the import data are from the same source file Add ID after name: set the import file name by the input value or the value in D
7-4-2 Import the C SV data
The purpose is to import the data from the SD card or U disk to TH register.
Step1:
Use function button
or function field , select import CSV data function.
Step2: Double click import CSV data, change the parameters as the following:
1. Source path tab
Please see the following picture: the import data when select start ID to 5 and 10.
Page 70
TH series Touch Screen User Manual Page 70 of 80 LMAN018_R2V2
When start ID is 5, import these data.
When start ID is 10, import these data.
There are 4 items in the title list.
There are four items in the CSV file.
When the start ID is 0 or 1, the import data is the first group.
2. Data tab
Please note the title list items must be the same as the CSV file items.
Register capacity: the import data group quantity
Register mode: Loop: the data will be stored in the object registers in loop mode, so the original data will be covered. Line: the data import to the object register one after another.
Add, delete, move up, move down, title….: Add the data title in the list, and select the data format, type, bit length,etc.
Page 71
TH series Touch Screen User Manual Page 71 of 80 LMAN018_R2V2
Add the date and time in the CSV file. Select the date and time format via the pull down menu.
3. Save tab:
4. Control tab:
Execute status: to show if it is in importing state via bit state. If the bit is ON, TH is importing data. Execute result: show the import result state via the register state. 0- import failed 0- import target device does not exist 1- the memory is not enough 2- file path error 3- reading / writing file failed
Execute process: show the importing process via register, 100 means the importing process is succeed.
5. Date time tab
Example: Purpose: import the data from object device to TH touch screen, select the import data group by input the start ID.
The CSV file in the SD card is SJDR.csv.
The import registers address.
Page 72
TH series Touch Screen User Manual Page 72 of 80 LMAN018_R2V2
In TH touch screen, the data store address starts from PSW400. The realize steps:
Step1: use function button
or function field . Set as the following:
Step2: build the import data group selection button.
Put a data input button on the screen-----
, change the parameters:
Change the object to PSW500 and be constant with the following import data dynamic appoint address.
Page 73
TH series Touch Screen User Manual Page 73 of 80 LMAN018_R2V2
Step3: double click “import CSV data”.
Import tab:
Save tab:
Control tab:
Device ID: 1
Path/File: SJDR.csv, must be the same as the object import file.
Fix name means importing from the same file.
Start ID: dynamic appoint PSW500.
Register capacity: 10, it means 10 groups of data
Register mode: line
Add the title: there are 4 rows of data.
Object: save the data of mobile device into TH register starts from PSW400.
Execute status: PSB300 to show the importing state Execute result: PSW256 to show the importing result Execute process: PSW257 to show the importing process
Page 74
TH series Touch Screen User Manual Page 74 of 80 LMAN018_R2V2
Date/time tab:
Step4: show the import data start from PSW400 in “data table”
.
Change the parameters:
Object tab:
Because the import data has time and date, select this item.
The object is PSW400, the same to the data import address.
Page 75
TH series Touch Screen User Manual Page 75 of 80 LMAN018_R2V2
Common tab:
Column tab:
The data table is finished, please see the following screen:
Set the all records, page records as the left window.
Add the text as the left window.
Set the date time item to time format.
Page 76
TH series Touch Screen User Manual Page 76 of 80 LMAN018_R2V2
Step5: Connect the mobile device and TH, click the import data button, monitor the data in “data table”.
NO Name Length Width Height Qty Date time
0 Group 1 60 12 10 25
2009-08-10 21:10:10
1 Group 2 60 20 8 35
2009-08-10 22:10:10
2 Group 3 65 10 10 20
2009-08-10 23:10:10
3 Group 4 65 12 5 15
2009-08-10 00:10:10
4 Group 5 65 18 15 15
2009-08-10 10:10:10
5 Group 6 65 20 8 30
2009-08-10 00:10:10
6 Group 7 70 8 8 18
2009-08-10 03:10:10
7 Group 8 70 16 10 18
2009-08-10 04:10:10
NO Name Length Width Height Qty Date time
0 Group 1 0 8 10 15
2009-08-10 12:10:10
1 Group 2 40 10 10 18
2009-08-10 13:10:10
2 Group 3 40 15 10 30
2009-08-10 14:10:10
3 Group 4 45 8 6 25
2009-08-10 15:10:10
4 Group 5 45 10 8 20
2009-08-10 16:10:10
5 Group 6 50 10 8 20
2009-08-10 17:10:10
6 Group 7 55 12 10 15
2009-08-10 18:10:10
7 Group 8 55 14 10 30
2009-08-10 19:10:10
When the import data No = 10, the data table is shown as up.
When the import data No = 0 or 1, the data table is shown as up.
Page 77
TH series Touch Screen User Manual Page 77 of 80 LMAN018_R2V2
8 TH series interior objects
This chapter will introduce the interior objects of the TH. The interior objects contain PSB(bit register), PSW(word register), PFW(word register).
Note:
1. Only when the advanced function is opened, the special interior objects can be used.
2. PSB0~PSB255, PSW0~PSW255, PFW0~PFW255 are occupied by system.
Bit register PSB
Register Function Remark
PSB0 Normally closed coil PSB1 Normally open coil PSB2 Turn on during the first scan period
PSB3 100ms pulse signal
ON OFF
50ms
50ms
PSB4 1s pulse signal
ON OFF
500ms
500ms
PSB5 1minute pulse signal
ON OFF
30s
30s
PSB6 300ms pulse signal
ON OFF
150ms
150ms
PSB15 Communication failure 0: successful 1: failed PSB16 Succeed to scan the screen once PSB30 First scan after download PSB31 First scan after power on PSB39 Turn off the touch screen PSB60 Level 1 password flag (1: password is opened, 0: password is closed ) PSB61 Level 2 password flag (1: password is opened, 0: password is closed ) PSB62 Level 3 password flag (1: password is opened, 0: password is closed ) PSB63 Level 4 password flag (1: password is opened, 0: password is closed ) PSB64 Level 5 password flag (1: password is opened, 0: password is closed ) PSB65 Level 6 password flag (1: password is opened, 0: password is closed ) PSB66 Level 7 password flag (1: password is opened, 0: password is closed ) PSB67 Level 8 password flag (1: password is opened, 0: password is closed ) PSB68 Level 9 password flag (1: password is opened, 0: password is closed )
Page 78
TH series Touch Screen User Manual Page 78 of 80 LMAN018_R2V2
Word register PSW
Register Function Remark
PSW0 Start screen No. PSW1 Current screen No. PSW20 Screen width ( read only ) PSW21 Screen height ( read only ) PSW26 PSB amounts ( read only ) PSW27 PSW amounts ( read only ) PSW28 PFW amounts
Occupy PSW28PSW29 ( read only ) PSW30 Year ( Hex) ( read only ) PSW31 Month ( Hex) ( read only ) PSW32 Day ( Hex) ( read only ) PSW33 Hour ( Hex) ( read only ) PSW34 Minute ( Hex) ( read only ) PSW35 Second ( Hex) ( read only ) PSW36 Week ( Hex) ( read only ) PSW40 Recipe index PSW54 The device quantity PSW60 COM1 communicate successful time PSW61 COM1 communicate failure time PSW62 COM1 communicate overtime time PSW63 COM1 communicate data error time PSW64 COM1 device version PSW65 COM1 device type PSW70 COM2 communicate successful time PSW71 COM2 communicate failure time PSW72 COM2 communicate overtime time PSW73 COM2 communicate data error time PSW74 COM2 device version PSW75 COM2 device type
Page 79
TH series Touch Screen User Manual Page 79 of 80 LMAN018_R2V2
Word register PFW
Register Function Remark
PFW1 The screen No. after power on PFW2 Background colour setting PFW10 Screen saver start time PFW11 The screen number of screen saver PFW20 COM1 baud rate
480096001920038400115200187500
PFW21 COM1 data bit
78 PFW22 COM1 stop bit 0-1 bit, 1-1.5 bits, 2-2 bits PFW23 COM1 CRC 0-None, 1-Odd, 2-Even PFW24 COM1 station NO. PFW25 COM2 send delay Unit : ms PFW30 COM2 baud rate
480096001920038400115200187500 PFW31 COM2 data bit
78 PFW32 COM2 stop bit 0-1 bit, 1-1.5 bits, 2-2 bits PFW33 COM2 CRC 0-None, 1-Odd, 2-Even PFW34 COM2 station NO. PFW35 COM2 send delay Unit: ms PFW60 Level 1 password
PFW60PFW61 PFW62 Level 2 password
PFW62PFW63 PFW64 Level 3 password
PFW64PFW65 PFW66 Level 4 password
PFW66PFW67 PFW68 Level 5 password
PFW68PFW69 PFW70 Level 6 password
PFW70PFW71 PFW72 Level 7 password
PFW72PFW73 PFW74 Level 8 password
PFW74PFW75 PFW76 Level 9 password
PFW76PFW77
Page 80
TH series Touch Screen User Manual Page 80 of 80 LMAN018_R2V2
For help and support regarding your XINJE products visit the online Support Centre or contact us on: support@listo-ltd.com.
www.listo-ltd.com
www.xinje-support-centre-listo.com
International partners with:
Documentation Reference
Document Number Revision Date
LMAN 018 R2 V2 18/07/2012
XINJE IS A REGISTERED TRADEMARK OF XINJE ELECTRICAL CO.LTD.
REPLICATION OF THE INFORMATION CONTAINED WITHIN THIS DOCUMENT
WITHOUT PRIOR NOTIFICATION AND AGREEMENT IS PROHIBITED.
Page 81
Contact us
Listo Ltd.
46a Derrymore Road Gawley’s Gate Co Armagh Northern Ireland BT67 0BW
0843 557 2130
info@listo-ltd.com
www.xinje-support-centre-listo.com
UK & Ireland Distributors for
Loading...