Listen Technologies RP 6004 User Manual

Page 1
DCS 6000
User Manual
Digital Conference System
RP 6004 Repeater
Danish Interpretation Systems DIS
Page 2
Danish Interpretation Systems User Manual
Copyright © 2003 Danish Interpretation Systems No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
Page 3
Danish Interpretation Systems User Manual
List of Contents
List of Contents................................................. 3
Document version ..........................................3
Important ......................................................... 4
Compliancy................................................... 4
Installation precautions ................................. 4
Cleaning ........................................................ 4
Repacking...................................................... 4
Warranty....................................................... 4
Description of the DCS 6000 system.................. 5
Features......................................................... 5
System components ....................................... 6
Central equipment .........................................6
Interpreter equipment....................................6
Conference equipment and channel selectors ..6
Operating instructions ...................................... 7
RP 6004 Repeater........................................... 7
General description ....................................... 7
Features.......................................................7
User Controls, indications & connectors........7
System design ..............................................8
System Setup ...................................................10
General guidelines........................................ 10
Built into 19” Racks ..................................... 10
Typical schematics ....................................... 11
Large sized conference microphone system.. 11 Various configurations with RP 6004 Repeater
and PS 6000 Power Supply ......................... 12
Technical appendix ......................................... 13
Cabling...................................................... 13
Accessories (not supplied) .......................... 13
Technical specifications................................ 13
Document version
Printed: 17-10-2004 Version: C Name: RP6004-REV-C.DOC
Copyright © 2003 Danish Interpretation Systems No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the
publisher.
Page 4
Danish Interpretation Systems User Manual
4
Important
Compliancy
The equipment has been tested and found to comply with the limits of the following standards for digital devices:
EN55103-1 (Emission)
EN55103-2 (Immunity)
FCC rules part 15, class A (Emission)
This de vice complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial or light industrial environment. The equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the user manual it may cause harmful interference to radio communications.
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
exposed to direct sunlight, excessive dust or humidity, mechanical vibration or shock.
To avoid moisture condensations do not install the unit where the temperature may rise rapidly.
Cleaning
To keep the cabinet in its original condition, peri odically clean it with a soft cloth. Stubborn stains may be removed with a cloth lightly dampened with a mild detergent solution. Never use organic solvents such as thinners or abrasive cleaners since these will damage the cabinet.
Repacking
Save the original shipping cardboard box and packing material; they will become handy if you ever have to ship the unit. For maximum protection, re-pack the unit as originally packed from the factory.
Warranty
The individual units in the DCS 6000 system are minimum covered by 12 months warranty against defects in materials or workmanship.
Installation precautions
Do not install the unit in a location near heat sources such as radiators or air ducts, or in a place .
Manual 01 18 04466
Page 5
Danish Interpretation Systems User Manual
5
Description of the DCS 6000 system
Features
The DCS 6000 system has the following main features:
Fully digital
Excellent sound quality
“State of the Art” fully digital integrated
interpretation, discussion and voting system offering interpretation, language distri bution, conference microphone and voting facili ties with attendance check with Chip Card ™.
New, unique digital DATA and AUDIO bus.
39 incoming channels (8 floor channels + 31
interpreted channels) and one Line input.
33 distributed channels (2 x floor + 31
interpreted channels)
The Delegate and Interpreter units are powered
and controlled by the CU 6010 Central Unit, which drives up to app. 200 units on 4 chains.
EX 6010 Extension Units or PS 6000 Power
Supplies available if more units are required
A total of 4000 units (delegate and/or
interpreter units) can be connected to the system.
Using screened CAT5 or CAT5e cabling (FTP
or STP) ensuring a very cost effective i nstallation and easy set-up of portable systems
RS232/RS422 connection on CU 6010 for
external operation of the system of a PC or control system such as AMX or Crestron
The SW 6000 is an optional software package, which expands the functionality of the DCS 6000 system. The software runs on standard computer technology (Standard PC with Windows 2000 or XP).
Main features of the SW 6000 are:
Mi crophone management
Mimic panel operation
Interpretation management
Voting ma nagement
Message handling
Agenda handling
Data stored on SQL data base for easy
export/import of data as well as easy links to external databases
Multi language user interfaces
Supports different User types with different
priorities, user interfaces and control possibilities
Variety of printing facilities such as speaker’s
log, voting results, delegates list etc.
Firmware in Delegate units, Interpreter Units,
Central Units etc. upgradeable through serial PC-connection (RS232 or RS422)
Can be operated with or without a PC.
Added functionality and comprehensive
features provided by SW 6000 software package running on PC
Manual 01 18 04466
Page 6
Danish Interpretation Systems User Manual
6
System components
The CU 6010 Central Unit supports all available units in the DCS 6000 series:
Central equipment
CU 6010 Central Unit EX 6010 Extension Power Unit PS 6000 Power Supply RP 6004 Repeater for four chains AO 6008 Audio Output box JB 6002 Junction Box with 2 outputs JB 6004 Junction Box with 4 outputs
Interpreter equipment
IS 6032P Interpreter Set IS 6132P Interpreter Set LS 6032P Interpreter Loudspeaker
Conference equipment and channel selectors
CS 6032FV/H Channel Selector (flush mounted) CM/DM 6010P Conference Unit (portable) CM/DM 6020P Conference Unit (portable) with
XLR microphone connector
CM/DM 6070P Conference Unit (portable) with
two built-in channel selectors
CM/DM 6090P Conference Unit (portable) with
two built -in channel selectors and XLR microphone connector
CM/DM 6060F Conference Unit (f lush mounted)
with one built-in channel selectors
CM/DM 6510F Conference Unit (flush mounted)
with Chip-card and 3 voting buttons
CM/DM 6560F Conference Unit (flush mounted)
with one built-in channel selector, Chip-card and 3 voting buttons
MU 6040C/D Microphone Unit for use with
customised front plate with Loudspeaker, Microphone and Buttons. Available in Delegate (D) and Chairman (C) version
AM 6040 Ambient Noise Microphone
Manual 01 18 04466
Page 7
Danish Interpretation Systems User Manual
7
Operating instructions
RP 6004 Repeater
General description
The RP 6004 Repeater provides repeater and splitter functionality for the DCS 6000 system.
One CU 6010 Central Unit is needed in each DCS 6000 system, however for expansion of the system the RP 6004 Repeater is suitable.
The RP 6004 consist of the following main parts:
Repeater board with 4 individual repeated
outputs.
User Controls, indications & connectors Front plate layout
Features
The main features of the RP 6004 Repeater are:
4 outputs for connection to Delegate Units,
Interpreter Units etc.
Loop through connectors for connecting
additional RP 6004 or other units, which are part of the DCS 6000 system.
Delayed switching on of power to the four
chains, to minimise the total ‘switch-on’ current on the Mains supply.
Designed in compact cabinet for easy installing
remotely.
Optional 19” brackets.
Front plate controls
The RP 6004 Repeater does not feature any controls or displays, however the following indications and connectors are available:
q Loop through connectors
RJ45 connector, 2 pieces DCS-LAN connectors. Used for connection to one
of the chain connector on the CU 6010 for repeating the DCS-LAN chain.
The second connector is for connection to other units with DCS-LAN connector, such as more RP
6004.
Manual 01 18 04466
The loop through connectors has auto-termination.
q Repeated Chain 1, 2, 3 & 4
RJ45 connector, 4 pieces DCS-LAN connectors. Used for connection to
DM/CM6xxx, CS6032, EX6010, AO6008, JB 6002/4 or IS6032 Interpreter Sets.
Unused repeated chains do not need termination
Page 8
Danish Interpretation Systems User Manual
8
q Power LED
Those LED light up when Power is available on the connector next to the LED
System design
There are no settings to be done on the RP 6004 Repeater.
However it is important to observe, that the unit is only repeating one of the chains on the CU 6010 Central Unit.
And as so, the specification, which applies to each of the chain outputs on the CU 6010 Central Units does also apply to all the repeated outputs in total.
So when designing a system to incorporate RP 6004 Repeaters, bare in mind, that as the RP 6004
‘Repeated chain’ connector
q Incoming data LED
Those LED flashes, when the unit receives incoming data from connected units on the connector next to the LED.
Repeater is repeating only one of the four outputs A (A1 or A2) or B (B1 or B2) the max. number of languages configured on the four outputs (1, 2, 3 and 4) is totally max. 16.
If more languages are required, Interpreter sets for those languages have to be connected either to an other RP 6004 Repeater, which is connected to the other of the two chains (A or B) on the CU 6010, or directly to the other of the two chains (A or B) on a CU 6010.
When connecting the RP 6004 Repeaters to the CU 6010 the first RP 6004 is connected to the ‘Loop through’ connector. The next RP 6004 Repeaters can be connected to either the other ‘Loop through’ connector or to one of the ‘Repeated out’
maximum two more RP 6004 Repeaters can be connected extending the maximum cable length in one chain up to 650 m. The above schematic is showing the connection using the ‘‘Repeated out’ connectors.
connectors. If using the ‘Repeated’ outputs
Manual 01 18 04466
Page 9
Danish Interpretation Systems User Manual
9
‘Loop through’ connector
When connecting a number of RP 6004 Repeaters to the CU 6010 an almost unlimited number of RP 6004 can be connected by using the ‘Loop through’ connector.
The practical limitation is the maximum cable length in one chain, which is 200 m and supply of power to the RP 6004 repeaters. The following schematic is showing the connections using the ‘Loop through’ connectors.
A combination of the two methods of connection can be seen in the ‘CU 6010 User Manual’.
Manual 01 18 04466
Page 10
Danish Interpretation Systems User Manual
10
System Setup
General guidelines
Connect the RP 6004 to the various units using Cat 5 FTP or STP cables. Please observe the following guide lines:
Maximum cable length in one chain is 200
m without repeater. This includes interconnection cables between the units. The max. usable cable length depends on the units connected and length of feeding cables etc.
Maximum cable length in one chain when
using repeaters is 650 m.
As the RP 6004 Repeater is repeating only
one of the four outputs A (A1 or A2) or B
Built into 19” Racks
The optional 19”-Brackets allow the unit to be mounted in a rack with either the front (connector side) or the blank backside to the front side of the rack. The height is 1HU and allows units to be stacked using only 44mm rack height.
(B1 or B2) the max. number of languages configured on the four outputs (1, 2, 3 and
4) is totally max. 16. If more languages are required, Interpreter
sets for those languages have to be divided between both chains (A or B) on the CU
6010. Normally the languages are supposed to be divided equally on chains A (A1 or A2) and B (B1 or B2).
If the last unit in one chain is a CS 6032
Channel Selector, this unit has to be terminated with an external termination, as the CS 6032 does not have an internal termination.
Can also be mounted at the back of the rack cabinet freeing the space at the front of the rack. The cabinet shall then be deep enough to allow this.
Manual 01 18 04466
Page 11
Danish Interpretation Systems User Manual
11
Typical schematics
The following schematics are showing various configurations:
Large sized conference microphone system
Manual 01 18 04466
Page 12
Danish Interpretation Systems User Manual
12
Various configurations with RP 6004 Repeater and PS 6000 Power Supply
Manual 01 18 04466
Page 13
Danish Interpretation Systems User Manual
13
Technical appendix
Cabling CAT5
The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors.
It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.
EIA 568-B wiring shall be used. How to wire a CAT5 (EIA 568-B) Cable:
Pin Function Connector #1 Connector #2
1 In-going + ORG/WHT ORG/WHT 2 In-going - ORG ORG 3 +48V GRN/WHT GRN/WHT 4 0V BLU BLU 5 0V BLU/WHT BLU/WHT 6 +48V GRN GRN 7 Outgoing - BRN/WHT BRN/WHT 8 Outgoing + BRN BRN
Note. If other colour codes are used then the four
pairs are connected as follows: Pair 1: Pin 1 & 2
Pair 2: Pin 3 & 6 Pair 3: Pin 4 & 5
Pair 4: Pin 7 & 8
The phase of the pairs must be correct and the wiring spec. as stated in CAT5 (EIA 568-B) have to be followed.
Note: CAT6 cables can normally only be terminated in sockets (female) and not in cable plugs. CAT6 should thus only be used for long cable draws terminating in wall outlets or patch panels.
Accessories (not supplied)
Cat 5e Connection Cables (AWG24)
EC 6000-..5 Connection Cable 0,5 m......................10 03 12500
EC 6000-01 Connection Cable 1 m.........................10 03 13101
EC 6000-02 Connection Cable 2 m.........................10 03 13201
EC 6000-05 Connection Cable 5 m.........................10 03 13501
EC 6000-10 Connection Cable 10 m.......................10 03 14102
EC 6000-20 Connection Cable 20 m.......................10 03 14202
EC 6000-50 Connection Cable 50 m.......................10 03 14502
Set of 1HU - 19” Brackets...........................................................
Technical specifications
General
Power consumption ....................................................max. 10W
Temperature to guarantee specified performance
.............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
..........................-20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight...................................................................................1 kg
Manual 01 18 04466
Dimensions (W x H x D)..............................264 x 42 x 128 mm
Dimensions with 19” brackets...................482,6 x 44 x 128 mm
Connectors
DCS-LAN loop through ........................................2 pieces RJ45
DCS-LAN repeated output ....................................4 pieces RJ45
Specifications are subject to change without notice.
Page 14
Danish Interpretation Systems User Manual
14
Manual 01 18 04466
Loading...