Listen Technologies R1 User Manual

LEARN COLLABORATE MEASURE DESIGN
At the very heart of Loopworks™ functionality is a ground-breaking hearing loop test and measurement system, Loopworks™ Measure.
Consisting of the Loopworks Measure R1 Receiver, an iOS App and the Loopworks™ online productivity suite, Loopworks™ Measure makes it possible for you to test the functionality of a hearing loop and it’s performance against standards
in the eld, store and share the results
online and issue reports and system
certicates. If used in combination with
Ampetronic C and D Series networkable drivers, Loopworks Measure enables you to control and test the driver remotely for fast and convenient commissioning and monitoring.
®
Featuring:
• Simple, intuitive user interface
• Standard measurement modes
• Field strength
• Frequency response
• Background noise
• Automated test result “Pass / Fail” Verdict system
• LoopLink to connect the app to C Series and D Series networkable drivers
• Record audio samples
• Built in protocols for standard test routines
• Automatically generated reports
and certicates featuring your
company logo.
• Project and system structure shared with Loopworks Design
Unit 2, Trentside Business Village, Farndon Road, Newark, NG24 4XB United Kingdom
Providing a genuine benet.
To nd more about what our app tool and support team can bring to your project, talk
to our experts on +44 (0) 1636 610612 or email: sales@ampetronic.co www.ampetronic.co
All contents, photographs and illustrations copyright © Ampetronic 2019
Measure
Commissioning verdicts guide
Loopworks™ is a ground-breaking hearing loop test and measurement system
Loopworks Measure app takes you through the steps required to perform a commissioning test. All of your test results for each section are recorded at multiple positions across the room.
Each test clearly shows a pass, qualied
pass or fail verdict live on screen. Results are collated within the app to give a simple overall verdict against relevant performance standards.
Knowing how verdicts are measured will give you the best chance of achieving
a pass when commissioning your next hearing loop system.
Overleaf is a handy guide to commissioning test verdicts from our Loopworks measure app.
Simple, powerful
functionality at your
ngertips
Commissioning
SIGNAL TYPES
Sine
ACCEPTANCE
Good / Pass
MENU
Signal Menu
MENU
Alignment Alert
SIGNAL TYPES
Sine
Pink
ACCEPTANCE
Good / Pass
Qualied Pass
MENU
Signal Menu
Capture
MENU
Alignment Alert
Start Test
SIGNAL TYPES
Sine
Pink
Combi
ACCEPTANCE
Good / Pass
Qualied Pass
Unacceptable / Fail
MENU
Signal Menu
Capture
Meter
MENU
Alignment Alert
Start Test
Stop Test
SIGNAL TYPES
Sine
Pink
Combi
Live
ACCEPTANCE
Good / Pass
Qualied Pass
Unacceptable / Fail
MENU
Signal Menu
Capture
Meter
Certify
MENU
Alignment Alert
Start Test
Stop Test
Test Points
SIGNAL TYPES
Sine
ACCEPTANCE
Good / Pass
MENU
Signal Menu
MENU
Alignment Alert
SIGNAL TYPES
Sine
Pink
Combi
Live
No Signal
System O
ACCEPTANCE
Good / Pass
Qualied Pass
Unacceptable / Fail
Help
Alignment Alert
MENU
Signal Menu
Capture
Meter
Certify
Settings
Reset
Results
Overall System Ver-
MENU
Alignment Alert
Start Test
Stop Test
Test Points
Results
Settings
Record
Measurements
MENU
Alignment Alert
Start Test
Stop Test
Test Points
Results
Settings
Record
Measurements
Designs
Help_o
Help_on
Measure
Design
Connect
Learn
Measure
Design
Connect
Learn
verdicts guide
Background noise
Field
strength
Area coverage From -3dB to +3dB
Service point From -6dB to +6dB From -7.5dB to +7.5dB
Individual test verdicts Section verdict
Pass Qualied pass Fail Pass Qualied pass Fail Notes
-32dB or below Above -32dB up to -22dB Above -22dB All tests pass
*
*
From -4.5dB to +4.5dB
Below -4.5dB or
above +4.5dB
Below -7.5dB or
All tests pass, at least one result is between 0dB and +3dB
above +7.5dB
Up to 50% of tests
qualied pass
Up to 50% of tests
qualied pass
Any test fails or more than 50% of tests
qualied pass
Any test fails or more than 50% of tests
qualied pass
Test signal: system off
At least four tests are required
Test signal: combi or sine
At least four tests are required
Frequency response
100Hz to 5kHz within ±3dB of 1kHz
100Hz or 5kHz within ±6dB of 1kHz and 125Hz to 4kHz within ±3dB of 1kHz
100Hz or 5kHz more than ±6dB from 1kHz or 125Hz to 4kHz more than ±3dB from 1kHz
All tests pass
Up to 50% of tests
qualied pass
Any answer fails or more than 50% of
answers qualied pass
Test signal: pink noise
At least four tests are required
Input signal? Yes No N/A
Live listening
Hum/buzz? Quiet Noticeable Very noisy
Quality? Clean Noticeable Distorted
Clarity? Clear Noticeable Unclear
All answers as pass
Up to 50% of answers
qualied pass
Any answer fails or more than 50% of
answers qualied pass
Test signal: live signals
To achieve an overall verdict of pass, this section must pass
No clipping? Yes Clips, audio OK Clipping
Below -9dB or above +6dB
Below -9dB or above +8dB
All tests pass
Up to 50% of tests
qualied pass
Any test fails or more than 50% of tests
qualied pass
Above -32dB All tests pass Any test qualied pass Any test fails
Above -22dB, if more than 3dB above
All tests pass Any test qualied pass Any test fails
background noise
Test signal: live signals
Only one test is required
Test signal: system on, no signal
Only one test is required
Test signal: combi or sine
No overspill test is required for overall verdict
Live eld
strength
System noise
Overspill
Area coverage From -6dB to +3dB From -9dB to +6dB
Service point From -6dB to +3dB From -9dB to +8dB
Below -47dB or within 3dB of background noise
Between -47dB and
-32dB
test
Below -32dB or within 3dB of background noise test
Above -32dB up to
-22dB, if more than 3dB above background noise
Signage? Yes N/A No
Venue accessibility
Where used? Yes No N/A
Trained staff? Yes N/A No
All answers as pass
Up to 50% of answers
qualied pass
Any answer fail or more than 50% of answers
qualied pass
Leaving any questions as ‘no answer’ will not affect overall verdict
Maintained? Yes No N/A
Connect
Learn
Measure
Design
Overall verdicts:
Pass = all sections are passes, will still pass if overspill and venue accessibility have no verdict.
Qualied pass = one or two sections are qualied passes, can still qualied pass if live listening, overspill and venue accessibility have no verdict.
Fail = any section is failed or three or more sections are qualied passes.
*
Selecting Australian standards, with metal present for the commissioning session, will increase eld strength qualied pass window for area coverage
systems to -9dB to +6dB.
Different limits apply to field strength tests for other signals
support@ampetronic.co
www.ampetronic.co
+44 (0) 1636 610062
UP38305-3
Loading...