Central Unit for series DCS 6000 Voting Units, Conference
Units, Interpreter Units, Ambient Noise Microphone, Channels
Selectors and Audio Output Units
The equipment has been tested and found to comply
with the limits of the following standards for digital
devices:
• EN55103-1 (Emission)
• EN55103-2 (Immunity)
• EN60065 safety
• UL6500 safety
• FCC rules part 15, class A (Emission)
The device complies with part 15 of the FCC rules.
Operation is subject to the following conditions: (1)
The device may not cause harmful interference, and
(2) the device must accept any interference
received, including interference that may cause
undesired operation.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in residential, commercial or
light industrial environments. The equipment
generates, uses, and can radiate radio frequency
energy and if not installed and used in accordance
with the user manual it may cause harmful
interference to radio communications.
You are cautioned that any changes or
modifications not expressly approved in this manual
could void your authority to operate this equipment.
Important safety instructions
The equipment must be connected to earth
Warning – To reduce the risk of fire or electric
shock, do not expose this apparatus to rain or
moisture.
Apparatus shall not be exposed to dripping or
splashing and no objects filled with liquids, such as
vases, shall be placed on the apparatus.
Labels
Lightning Flash Symbol, with
"The Lightning Flash with
arrowhead symbol within an
equilateral triangle, is intended
to alert the user to the presence
of uninsulated "dangerous
voltage" within the product
enclosure that may be of sufficient magnitude to
constitute a risk of shock to persons"
Exclamation Point Symbol,
with "The exclamation point
within an equilateral triangle is
intended to alert the user to the
presence of important
operating and maintenance
(servicing) instructions in the
literature accompanying the product"
Check that the voltage of your local power supply is
within the operating voltage of the unit (100-240V
AC). If a voltage conversion is required, consult
your DIS dealer or qualified personnel.
Should any liquid or solid object fall into the
cabinet, unplug the unit and have it checked by
qualified personnel before operating it further.
Set the Power switch to OFF if it is not used for
several days.
Manual 01 18 04438
Installation precautions
Allow adequate air circulation to prevent internal
heat built-up. Do not place the unit on a surface
(rugs, blankets, etc.) that may block the ventilation
holes.
Do not install the unit in a location near heat
sources such as radiators or air ducts, or in a place
exposed to direct sunlight, excessive dust or
humidity, mechanical vibration or shock.
5
Danish Interpretation Systems User Manual
To avoid moisture condensations do not install the
unit where the temperature may rise rapidly.
Warranty
When installing the unit inside a 19” rack, observe
that the rack is properly ventilated. The maximum
allowed temperature inside the rack is 40 °C.
Cleaning & Repacking
To keep the cabinet in its original condition,
periodically clean it with a soft cloth. Stubborn
stains may be removed with a cloth lightly
dampened with a mild detergent solution. Never use
organic solvents such as thinners or abrasive
cleaners since these will damage the cabinet.
Save the original shipping cardboard box and
packing material; they will become handy if you
ever have to ship the unit. For maximum protection,
re-pack the unit as originally packed from the
factory.
The unit is minimum covered by 12 months
warranty against defects in materials or workmanship.
6
Manual 01 18 04438
Danish Interpretation Systems User Manual
Description of the DCS 6000 system
Features
The DCS 6000 system has the following main
features:
• Fully digital
• Excellent sound quality
• “State of the Art” fully digital integrated
interpretation, discussion and voting system
offering interpretation, language distribution,
conference microphone and voting facilities
with attendance check with Chip Card ™.
• Unique digital DATA and AUDIO bus.
• 39 incoming channels (8 floor channels + 31
interpreted channels) and one Line input.
• 34 distributed channels (3 x floor + 31
interpreted channels)
• The Delegate and Interpreter units are powered
and controlled by the CU 6005 Central Unit,
which drives up to app. 50 units on 2 chains or
by the CU 6010/6011 Central Unit, which
drives up to app. 200 units on 4 chains.
• Added functionality and comprehensive
features provided by SW 6000 software
package running on PC
RS232/RS422 connection on CU
6005/6010/6011 for external operation of the
system of a PC or control system such as AMX
or Crestron
The SW 6000 is an optional software package,
which expands the functionality of the DCS 6000
system. The software runs on standard computer
technology (Standard PC with Windows 2000 or
XP).
Main features of the SW 6000 are:
• Microphone management
• Mimic panel operation
• Interpretation management
• Voting management
• Message handling
• Agenda handling
• Data stored on SQL data base
• EX 6010 Extension Units or PS 6000 Power
Supplies available if more units are required
• A total of 4000 units (delegate and/or
interpreter units) can be connected to the
system.
• Using screened CAT5 or CAT5e cabling (FTP
or STP) ensuring a very cost effective
installation and easy set-up of portable systems
• Firmware in Delegate units, Interpreter Units,
Central Units etc. upgradeable through serial
PC-connection (RS232 or RS422)
• Can be operated with or without a PC.
Manual 01 18 04438
•Web service interface available for easy links
to external applications
• Multi language user interfaces
• Supports different User types with different
priorities, user interfaces and control
possibilities
•Variety of printing facilities such as speaker’s
log, voting results, delegates list etc.
7
Danish Interpretation Systems User Manual
System components
The CU 6005/6010/6011 Central Unit supports all
available units in the DCS 6000 series:
Central equipment etc.
EX 6010 Extension Unit
PS 6000 Power Supply
AO 6004 Audio Output box
AO 6008 Audio Output box
RP 6004 Repeater for four chains
JB 6002 Junction Box with 2 outputs
JB 6004 Junction Box with 4 outputs
Interpreter equipment
IS 6132P Interpreter Set
LS 6132P Interpreter Loudspeaker
Voting equipment
DV 6501F Voting Unit
Important: For the use of above mentioned equipment connected to a CU 6005/6010/6011 Central Unit,
please refer to the User Manuals for the equipment.
selectors
CS 6032F V/H Channel Selector (flush mounted)
DC 6990P Conference Unit (portable) with
touch screen
DM 6010P Conference Unit (portable)
DM 6060P Conference Unit (portable) with
one built-in channel selector
CM/DM 6070P Conference Unit (portable) with
two built-in channel selectors
CM/DM 6090P Conference Unit (portable) with
two built-in channel selectors and
XLR microphone connector
CM/DM 6060F Conference Unit (flush mounted)
with one built-in channel
selectors
CM/DM 6510F Conference Unit (flush mounted)
with Chip-card and 3 voting
buttons
CM/DM 6560F Conference Unit (flush mounted)
with one built-in channel
selector, Chip-card and 3 voting
buttons
MU 6040C/D Microphone Unit for use with
customised front plate with
Loudspeaker, Microphone and
Buttons. Available in Delegate
(D) and Chairman (C) version
MU 6042D Dual Microphone Unit for use
with FD/FC front plate with
Loudspeaker, Microphone and
two delegate Buttons
AM 6040 Ambient Noise Microphone
Conference equipment and channel
8
Manual 01 18 04438
Danish Interpretation Systems User Manual
Operating instructions
CU 6010 Central Unit
General description
The CU 6010 Central Unit for the DCS 6000 is the
heart of the system. One CU 6010 is needed in each
DCS 6000 system. The CU 6010 consist of four
main parts:
• Main processor board with Power PC and DSP
• DCS-LAN Network Control Card with 4
individual DCS-LAN outputs
• 4 individual Power supplies
• LCD display and buttons for system settings
The design with built in power supply makes the
unit suitable for running a small system alone or to
be the Central Controller for a large system.
Features
The main features of the CU 6010 Central Unit are:
• Controls up to 4000 units (Conference units,
Interpreter units or other controllable units).
This number does not include Channel
Selectors, Repeaters etc. In practical use there
are no limits for the number of Channel
Selectors in a system.
• Designed for 31 interpreted channels and 8
open microphones
• Operated either stand alone or from an IBM
compatible PC with SW 6000 software running
under Windows 2000 or XP.
• Built in Power Supplies for app 200 units
(Delegate) or app. 600 Channel Selectors
• 4 outputs for connection to Delegate Units,
Interpreter Units etc.
• Delayed switching on of power to the four
chains, to minimise the total ‘in-rush’ current
on the Mains supply.
• Designed in a standard 2HE 19” cabinet.
• Functionality on the CU 6010 depends on the
Feature License uploaded into the unit.
Feature License
The CU 6010 Central Unit has as standard basic
functionality.
• Conference Units: max. 50
This count includes DM, CM, DV units.
Dual Delegate units count for 2 units.
• Secure audio transmission: No
• Vox, voice activating: No
• Voting: No
• Interpretation Channels: 1-4
By obtaining feature licenses, the functionality can
be expanded to include further functionality like:
• Conference Units, max.100, max. 500,
max. 1000 or max. 3800
This count includes DM, CM, DV units.
Dual Delegate units count for 2 units
• Secure audio transmission
• Voting option
• VOX, Voice Activation
• Interpreter Channels, 1-8 channels, 1-16
channels or 1-31 channels
• 3 part voting control using RS232 port on
CU 6010
The file with the Feature License key is delivered
from your authorised DIS Distributor or Dealer and
can be uploaded in the CU using a standard PC or
Laptop. For details about uploading the Feature
license, please consult the User Manual “DCS6000
Feature License Key”.
This manual describes all features available
Manual 01 18 04438
9
Danish Interpretation Systems User Manual
User Controls, indications & connectors
Front plate layout
The front plate layout of the CU 6010 Central Unit consists of a large illuminated LCD display and 8 buttons for
setting up/controlling the system:
Details of display
-Audio Control
-Delegate setup
-Interpreter setup
-Units info
MENUENTER
Front plate controls
The CU 6010 Central unit features the following
controls and display:
Power switch
Switches power on to the whole system. When
power is switched ON at the CU 6010 any
connected EX 6010 Extension Units will
automatically be powered up. An indication in the
switch is lighting, when power is switched ON
The Fault LED will always light up some seconds
after the unit is switched on caused by the delayed
switching on of the four supplies.
As a warning the light is flashing at an internal
temperature above 45°C. At a temperature above
55°C or if one of the DCS-LAN outputs is
supplying no voltage, the LED is lighting
constantly.
Please note that the maximum ambient temperature
for the CU 6010 is 40 deg. Celsius.
Fault LED
This indication lights up, if the internal power
supply is malfunctioning i.e. because of overheating
or overload of a chain.
10
Manual 01 18 04438
LCD Display
This display is used for information purposes and
set-up purposes.
Danish Interpretation Systems User Manual
Buttons
The buttons below and to the left of the display are
used when stepping through the different menus
and for setting up the system:
‘-‘
The dash symbol (‘-‘) preceding a line of text
identifies a submenu or a changeable parameter.
The submenu or parameter can be selected by
pressing the corresponding select button.
•
Four select buttons
Four buttons placed on the left-hand side of the
display. Each button is associated with a line
pointing towards a text line in the display. This
indicates, that pushing the button ‘selects’ the
functionality.
‘>’
The ‘>’ symbol preceding a line of text identifies a
selected parameter. The parameter can be changed
by pressing the up and down buttons. The ‘>’
symbol is shown as long as the value of the
parameter currently used is the same as the value
•
Enter button
shown in the display.
The Enter button is used, when a selection is made
in the Main Menu. Pressing the Enter button
concludes the selection made, and at the same time
it indicates a confirmation of the possible changes
made within the selection. The Menu system returns
to the previous menu. Notice, that some changes are
applied immediately, and confirmation is thus not
required.
‘*’
The star symbol ‘*’ preceding a line of text
identifies a selected parameter, where the value has
been changed, but not yet confirmed. The changed
value can be confirmed by pressing the Enter
button, or it can be dismissed by pressing the Menu
button.
•
Menu button
The Menu button is also used, when a selection is
made in the Main Menu. The Menu button
concludes the selection, but in contrast to the Enter
button, the Menu button does not confirm a possible
change made within the selection. Instead, the
Menu system returns to the previous menu without
confirming changes, if confirmation is required.
•
Up (▲) and Down (▼) buttons
The Up and Down buttons are used to scroll
through menu items, or to increase/decrease values
within a selection.
Symbols
The following symbols are used on the LCD
display:
‘▲▼’
The up and down symbols shown in the right side
of the display (up is shown in the first line and
down is shown in the last line) indicates that the
current menu consists of more than 4 menu items. It
is therefore necessary to use the up and down
buttons to scroll through menu items.
Indications
Cursor
The cursor is used on the LCD display to indicate,
when a value is being changed. For a parameter that
is subject to a change, the cursor is placed at the
value of the parameter, indicating that it is about to
be changed.
Manual 01 18 04438
11
Danish Interpretation Systems User Manual
Back Panel Layout
Back Panel Connectors
Mains Power connector
Connection for mains power. See specs.
Analog Audio Line input
XLR Input connector.
For connection of external Line input signal i.e. the
Floor (Speaker) signal from another Conference
Microphone System or audio mixers. See specs.
Analog Audio Line output.
XLR Output connector.
This connector carries the “Floor” signal. It is used
either for recording purposes or for feeding signal
to an external loudspeaker system. See specs.
Serial Data Communication RS232
D-Sub9 connector
RS232 Serial connection for communication to PC
etc. Either the RS232 or the RS422 can be used.
Serial Data Communication RS422
D-Sub 9 connector
RS422 Serial connection for communication to PC
etc. Either the RS232 or the RS422 can be used.
Chain A1 & A2
RJ45 connector, 2 pieces
DCS-LAN connectors for connection to DM/CM
6xxx, IS 6032, IS 6132, CS 6032, EX 6010, AO
6004/6008 etc. For connecting Interpreter Sets for
up to 16 languages. If more languages are required,
Interpreter sets for those languages have to be
connected to Chain B1 or B2.
Chain B1 & B2
RJ45 connector, 2 pieces
DCS-LAN connectors for connection to DM/CM
6xxx, IS 6032, IS 6132, CS 6032, EX 6010, AO
6004/6008 etc. For connecting Interpreter Sets for
up to 16 languages. If more languages are required,
Interpreter sets for those languages have to be
connected to Chain A1 or A2.
Power LED’s
Those LED’s light up when Power is available on
the connector next to the LED and only if the
voltage is over 24V (not overloaded).
System settings
Control of the system settings is done through
selections made in the main menu. Pressing the
Menu button will show the Main menu, which
comprises the following entries:
• Audio control
• Delegate setup
• Interpreter setup
• Ambient Microphone
• Units info
• RS232 setup
• Security setup
• Configuration
• License info
• Firmware info
12
Manual 01 18 04438