liniLED Diffuse, Top Diffuse 18, Top Diffuse 12, Side Diffuse Series Manual

V DC
Manual
liniLED® Diuse
F
GLOW WIRE
RoHS
850 °C
IP68
+
IP69K
IK08
R
BEND RADIUS
150 mm
24
CLEANING
UV
FROST
SEA
SWIMMING POOL
SUBMERSIBLE
CRI
80
MAC
ADAM
+
S D C M
5
3
System
liniLED® Diuse
Technical notes 4 Top Diuse 12 5
Product drawings
Technical specications
Top Diuse 18 6
Product drawings
Technical specications
Side Diuse 7
Product drawings
Technical specications
Product care and handling 8 Area advice 9 Connectors 10 Installation 11 Cable selection 13 Power supply 14 Symbols 15
Technical notes
Read the instructions and safety precautions before installation, usage and storage of the products to secure safety of the user and reliability of the product.
- Hand over the instructions to the end user and those responsible for installation and usage.
- Triolight B.V. cannot be held responsible for improper handling, product installation, usage or storage.
Handling
- Handle with care.
- The product may not be modi ed or converted otherwise than prescribed.
- Products are transported in proper packaging. Products should remain packed until installation.
- Take ESD (Electrostatic Discharge) protection measures when handling liniLED® products.
- The products and their components may not be exposed to mechanical, static loads and other tension/compression other than from the product itself.
Installation
- Attention: The power has to be switched o the main power supply or the connection before installation. Not doing so may damage the product.
- Use a suitable LED power supply/driver: 24 V DC constant voltage. Do not drive the product on other voltages than described in their datasheet/products
speci cations.
- Installation has to be done by a certi ed professional with knowledge of electrical circuits or a specialised maintenance person known with valid directives.
- General and local construction-, safety- and installation regulations should be respected.
- Use only supplied parts, accessories and required tools as prescribed in the installation manual to guarantee a safe installation and use of the product.
- Products may solely be installed in the areas according to their prescribed IP-rating, IK-rating, temperature range and chemical resistances.
- The LED strip should be installed on an adequate cooling body for proper heat dissipation to ensure smooth operation and long lifetime.
- Do not fasten anything on the product, same applies for hanging.
- Do not install the product in the following cases:
- Damage is visible on the product or its cables.
- The inside of the product is moistened or dirty.
- The product or its cables have been modi ed. It could lead to an electrical shock or a short circuit may occur.
- Children may not play unsupervised with electrical products as they cannot judge the dangers in dealing with electrical circuits correctly.
- Use proper mounting surfaces when installing in environments with large variations in temperature and operating lengths more than 2m. This should
absorb the stress of any mismatch in expansion.
Operation and use
Solely use the product when its working correctly. If not, switch the power o immediately and advise an electrical specialist in the following cases:
- Damage is visible on the product and/or the product does not function.
- The product is overheating and/or smoke or steam rises from the product.
- Crackling sounds are noticeable.
- Repairs on the installation may only be performed by quali ed electricians. Product repairs may solely be done by Triolight B.V.
Cleaning and maintenance
- Attention: Disconnect the power before maintenance and cleaning.
- Dust and dirt accumulated over time should be removed from the light emitting surface to assure optimal functioning of the product.
- Paints, solvents and corrosive cleaning chemicals may not contact and thus a ect the product.
Environment and waste
- Exterior decorative lighting should only be used after sunset.
- This product may not be treated as household waste. Dispose of the material through the waste recycling of electrical and electronic equipment.
Warranty
This product comes with a 2 year warranty. Warranty void if:
- The installation guide has not been consulted (installation mistake).
- The installation is not done by a certi ed installer.
- Local rules and guidelines are not respected.
- The invoice cannot be shown and/or has been altered.
- Damage is caused by negligence, abnormal use or improper handling, use, maintenance and/or cleaning of the product.
Manual | liniLED® Diuse
4
Top Diuse 12 - Product drawings
12
18
33
LED strip length
3
18
10
4.5
1000/5000 mm
Top Diuse 12 - Technical specications
Ultra Warm White Extra Warm White Warm White Natural White Cold White
Top Diuse 12
Product code 11829 11830 11831 11832 11833
Typical CCT 2309K 2534K 2828K 3700K 6201K
Power (24 V DC) 8.9 W/m 8.9 W/m 8.3 W/m 8.6 W/m 8.6 W/m
Power (25 V DC) 9.3 W/m 9.3 W/m 8.6 W/m 9.0 W/m 9.0 W/m
Luminous ux 167 lm/m 185 lm/m 169 lm/m 181 lm/m 184 lm/m
Luminous eciency 19 lm/W 21 lm/W 20 lm/W 21 lm/W 21 lm/W
CRI > 88 > 91 > 90 > 92 > 92
Binning ± 50K
MacAdam 3 steps
Output signal PWM dimming, 24 V DC Common Anode
LED Duris® E3
Number of LEDs 6 per section/120 per metre
Operating voltage 24 V DC
Max. operating voltage 25 V DC
Spool length Max. 10 m
Section length 5 cm
Max. connection length 10 m
Expected lifetime B50/L70 > 60,000 hours @ Tc = 40°C
Ingress protection IP68+ > 50 m/IP69K
Storage temperature -30°C ... 55°C
Operating temperature -30°C ... 55°C
Minimal bending radius 150 mm
Dimensions 12x18 mm
Weight 240 gram per metre
Max. connection length between -30°C ... -20°C is 7 metres.
Manual | liniLED® Diuse
5
Top Diuse 18 - Product drawings
18
18
33
LED strip length
3
18
10
4.5
Top Diuse 18 - Technical specications
Ultra Warm White Extra Warm White Warm White Natural White Cold White
2400K 2700K 3000K 4000K 6500K
Top Diuse 18
Product code 11799 11800 11801 11802 11803
Typical CCT 2309K 2610K 2873K 3787K 6370K
Power (24 V DC) 8.9 W/m 8.9 W/m 8.3 W/m 8.6 W/m 8.6 W/m
Power (25 V DC) 9.3 W/m 9.3 W/m 8.6 W/m 9.0 W/m 9.0 W/m
Luminous ux
Luminous eciency 22 lm/W 25 lm/W 24 lm/W 25 lm/W 26 lm/W
CRI > 88 > 90 > 89 > 91 > 92
Binning ± 50K
MacAdam 3 steps
Output signal PWM dimming, 24 V DC Common Anode
LED Duris® E3
Number of LEDs 6 per section/120 per metre
Operating voltage 24 V DC
Max. operating voltage 25 V DC
Spool length Max. 10 m
Section length 5 cm
Max. connection length 10 m
Expected lifetime B50/L70 > 60,000 hours @ Tc = 40°C
Ingress protection IP68+ > 50 m/IP69K
Storage temperature -30°C ... 55°C
Operating temperature -30°C ... 55°C
Minimal bending radius 150 mm
Dimensions 18x18 mm
Weight 340 gram per metre
200 lm/m 220 lm/m
196 lm/m 213 lm/m
226 lm/m
1000/5000 mm
Max. connection length between -30°C ... -20°C is 7 metres.
Manual | liniLED® Diuse
6
Side Diuse - Product drawings
12
18
33
LED strip length
3
18
10
4.5
1000/5000 mm
Side Diuse - Technical specications
Ultra Warm White Extra Warm White Warm White Natural White Cold White
2400K 2700K 3000K 4000K 6500K
Side Diuse
Product code 11819 11820 11821 11822 11823
Typical CCT 2243K 2533K 2866K 3724K 6091K
Power (24 V DC) 8.9 W/m 8.9 W/m 8.3 W/m 8.6 W/m 8.6 W/m
Power (25 V DC) 9.3 W/m 9.3 W/m 8.6 W/m 9.0 W/m 9.0 W/m
Luminous ux
Luminous eciency 11 lm/W 13 lm/W 12 lm/W 13 lm/W 13 lm/W
CRI > 89 > 91 > 90 > 93 > 93
Binning ± 50K
MacAdam 3 steps
Output signal PWM dimming, 24 V DC Common Anode
LED Duris® E3
Number of LEDs 6 per section/120 per metre
Operating voltage 24 V DC
Max. operating voltage 25 V DC
Spool length Max. 10 m
Section length 5 cm
Max. connection length 10 m
Expected lifetime B50/L70 > 60,000 hours @ Tc = 40°C
Ingress protection IP68+ > 50 m/IP69K
Storage temperature -30°C ... 55°C
Operating temperature -30°C ... 55°C
Minimal bending radius 150 mm
Dimensions 12x18 mm
Weight 240 gram per metre
102 lm/m 113 lm/m
101 lm/m 116 lm/m
111 lm/m
Max. connection length between -30°C ... -20°C is 7 metres.
Manual | liniLED® Diuse
7
Product care and handling
150 mm
150 mm
The direction of bending, the radius of the bend and general handling instructions are explained on this page.
Top Diuse
Solely bend the liniLED® Top Diuse LED strip in up- and downward direction when the light surface is facing upwards.
Side Diuse
Top Diuse
Do not bend the liniLED®Top Diuse LED strip in sideward direction when
the light surface is facing upwards.
Side Diuse
Solely bend the liniLED® Side Diuse LED strip in sideward direction when the light surface is facing upwards.
Do not bend the liniLED® Side Diuse LED strip in up- and downward
direction when the light surface is facing upwards.
Top/Side Diuse Top/Side Diuse
The minimum bending radius of the liniLED® Diuse LED strips are 150 mm.
Do not twist, stretch or compress the liniLED® Diuse LED strips.
Manual | liniLED® Diuse
8
Connectors
The liniLED® Diuse LED strips come with a pre-assembled connector, available in dierent types. Extending LED strip can be achieved with the liniLED® Diuse
Extension Cord. Below is an overview of the available types with corresponding cable lengths and article numbers.
Product drawings (side view) Product code Cable length
Diuse Connector 90º Angle
IP20
IP20
11260 liniLED® Diuse Connector 90º Angle 12 1 m 11261 liniLED® Diuse Connector 90º Angle 12 5 m
11245 liniLED® Diuse Connector 90º Angle 18 1 m 11246 liniLED® Diuse Connector 90º Angle 18 5 m
Diuse Connector Straight
11270 liniLED® Diuse Connector Straight 12 1 m 11271 liniLED® Diuse Connector Straight 12 5 m
11250 liniLED® Diuse Connector Straight 18 5 m 11251 liniLED® Diuse Connector Straight 18 5 m
Diuse Extension Cord
11277 liniLED® Diuse Extension Cord Angle 12 11279 liniLED® Diuse Extension Cord Straight 12
11276 liniLED® Diuse Extension Cord Angle 18 11278 liniLED® Diuse Extension Cord Straight 18
1000 mm 5000 mm
1000 mm 5000 mm
1000 mm 5000 mm
1000 mm 5000 mm
300 mm 300 mm
300 mm 300 mm
IP67
IP67
IP67
IP67
Diuse Connector Male
11284 liniLED® Diuse Connector Angle Male 12 11286 liniLED® Diuse Connector Straight Male 12
11280 liniLED® Diuse Connector Angle Male 18 11282 liniLED® Diuse Connector Straight Male 18
Diuse Connector Female
11285 liniLED® Diuse Connector Angle Female 12 11287 liniLED® Diuse Connector Straight Female 12
11281 liniLED® Diuse Connector Angle Female 18 11283 liniLED® Diuse Connector Straight Female 18
Connection Cable Female
11274 liniLED® Connection Cable Female 5 m
300 mm 300 mm
300 mm 300 mm
300 mm 300 mm
300 mm 300 mm
5000 mm
Manual | liniLED® Diuse
9
25 mm
Installation
1
Make sure the power is OFF when you start the installation. Unspool the LED strip on a horizontal surface.
3
2
4
Make sure the liniLED® Diuse LED strip and the U-Prole are aligned. Gently push the liniLED® Diuse LED strip into the U-Prole.
5
Long lengths should be installed by two installers to prevent the LED strip from twisting or bending.
6
Minimum bending radius of the cable is 25 mm.
Manual | liniLED® Diuse
10
FemaleMale
Male
Female
Installation
Step 7 till 10 are optional. Only if provided with IP67 connector.
7
Optional Female connector front and isometric view, notice the white
marker on top (highlighted in orange in the image above).
9
8
Optional Male connector front and isometric view, notice the white
marker on top (highlighted in orange in the image above).
10
Optional Align the white marker of the Female and Male connector. Optional - Snap the connector while keeping the white marker aligned.
11
Turn the power ON.
Manual | liniLED® Diuse
11
Cable selection
1 = Select colour temperature.
2 = Select LED strip length.
1
Diuse Connector (1000 mm)
3 = Select output voltage.
4 = Select cable cross section.
Result = Maximum cable length based
on the cable thickness and power supply
2
voltage.
Colour temperature
1.
LED strip length 1 m 2 m 5 m 10 m
2.
Output voltage 24 V DC 25 V DC 24 V DC 25 V DC 24 V DC 25 V DC 24 V DC 25 V DC
3.
4.
Cable cross section
0.50 mm - 0.035 Ω/m
0.75 mm - 0.023 Ω/m 50.4 m 98.6 m 24.2m 48.3 m 8.5 m 18.1 m 3.3 m 8.1 m
1.00 mm - 0.018 Ω/m 67.0 m 131.1 m 32.2 m 64.2 m 11.3 m 24.1 m 4.3 m 10.8 m
1.50 mm - 0.012 Ω/m 100.9 m 197.2 m 48.5 m 96.7 m 17.0 m 36.3 m 6.6 m 16.2 m
2.50 mm - 0.007 Ω/m
2400K, 2700K
33.5 m 65.5 m 16.1 m 32.1 m 5.6 m 12.0 m 2.1 m 5.4 m
167.9 m 328.3 m 80.7 m 160.9 m 28.4 m 60.5 m 11.0 m 27.0 m
result
4
3
-+
Colour temperature
1.
LED strip length 1 m 2 m 5 m 10 m
2.
Output voltage 24 V DC 25 V DC 24 V DC 25 V DC 24 V DC 25 V DC 24 V DC 25 V DC
3.
4.
Cable cross section
Colour temperature
1.
LED strip length 1 m 2 m 5 m 10 m
2.
Output voltage 24 V DC 25 V DC 24 V DC 25 V DC 24 V DC 25 V DC 24 V DC 25 V DC
3.
4.
Cable cross section
0.50 mm - 0.035 Ω/m
0.75 mm - 0.023 Ω/m 54.2 m 105.9 m 24.25m 48.35 m 9.3 m 19.6 m 3.6 m 8.8 m
1.00 mm - 0.018 Ω/m 72.1 m 140.8 m 32.25 m 64.29 m 12.3 m 26.1 m 4.8 m 11.7 m
1.50 mm - 0.012 Ω/m 108.4 m 211.8 m 48.51 m 96.71 m 18.6 m 39.2 m 7.3 m 17.7 m
2.50 mm - 0.007 Ω/m
0.50 mm - 0.035 Ω/m
0.75 mm - 0.023 Ω/m 52.2 m 102.1 m 25.1 m 50.1 m 8.9 m 18.8 m 3.4 m 8.4 m
1.00 mm - 0.018 Ω/m 69.5 m 135.8 m 33.4 m 66.6 m 11.8 m 25.1 m 4.6 m 11.2 m
3000K
36.0 m 70.4 m 16.12 m 32.14 m 6.1 m 13.0 m 2.4 m 5.8 m
180.5 m 352.5 m 80.74 m 160.95 m 30.9 m 65.3 m 12.2 m 29.4 m
4000K, 6500K
34.7 m 67.9 m 16.7 m 33.3 m 5.9 m 12.5 m 2.3 m 5.6 m
1.50 mm - 0.012 Ω/m 104.5 m 204.3 m 50.3 m 100.2 m 17.8 m 37.7 m 6.9 m 16.9 m
2.50 mm - 0.007 Ω/m
174.0 m 340.0 m 83.7 m 166.7 m 29.6 m 62.8 m 11.6 m 28.2 m
Note: Calculations are based on a standard connector with 1 metre cable (0,5 mm).
Manual | liniLED® Diuse
12
liniLED® Control solution
(optional)
L N
Power Supply
24 V DC
-+
230 V AC
IP68+/IP69K
IP68+/IP69K
IP68+/IP69K
Power supply
Manual | liniLED® Diuse
13
Symbols
C
Disclaimer
The published information is checked to be as accurate as possible, however Triolight B.V. or any reseller of liniLED® cannot be held liable for any damages resulting
from errors or outdated information. Triolight B.V. reserves the right to modify the information without informing the customers. When this document is printed or
downloaded, please check for the latest version on the internet, the most up to date information will be published on www.liniLED.com. This product should not
be used in applications, devices or systems where incorrect operation of the product may result in personal injury (includes emergency lighting) without written
permission from the board of Triolight B.V. If nevertheless used in such applications, devices or systems Triolight B.V. cannot be held liable for any resulting injury.
F
Manufacturer’s declaration that the product meets the applicable EC directives.
Suitable for mounting on all surfaces and suitable to cover with insulating material.
GLOW WIRE
RoHS
IP68
IP69K
CRI
80
MAC
ADAM
S D C M
IK08
R
BEND RADIUS
850 °C
Restriction of Hazardous Substances (RoHS): product complies with the RoHS directive and each homogeneous material does not exceed the limits for the materials mentioned under the RoHS directive (Pb, Hg, Cd, Cr6+, PBB and PBDE).
Passed glow wire test at 850 degrees Celsius. Global European regulations specify 650 degrees Celsius by default.
Dust-tight, no ingress of dust. Protected against the eects of continuous immersion in water
+
(immersion in water at a maximum depth of 50 metres). Only in combination with the liniLED® Mirror Welded Connector.
Dust- tight, no ingress of dust. Protected against close-range high pressure, high temperature spray downs. Only in combination with the liniLED® Mirror welded connector.
The CRI value of this product is 80 or higher.
+
The binning tolerance of this product is 3 MacAdam.
3
Protected against impact energy of 5 joules.
150 mm
Bending of the LED strip is possible with a radius of ≥ 150 millimetres in the specied direction.
24
V D
Operating voltage of 24 V DC.
Electrical appliance class III: this product is designed to be supplied from an extra-low voltage (≤ 60.0 V DC or ≤ 42.4 V AC).
Product is resistant against ultraviolet (UV) light or sunlight. Non-UV resistant products can degrade or discolour fast when exposed to UV light.
UV
CLEANING
FROST
Product can be cleaned with normal cleaning agents as specied in the datasheet under ‘chemical compliances’.
This product can be stored and used below 0 degrees Celsius. Verify the minimum storage and operation temperature in the datasheet or manual for the lowest temperature allowed.
SEA
This product can be applied in seawater and its environment. Elements in seawater will have no harmful eect on the product. For chemical specications see datasheet. Verify the IP rating for proper use.
Manual | liniLED® Diuse
14
Symbols
POOL CL
POOL CL
This product can be applied inside swimming pool environments. Elements in the air will have no harmful eect on the product. For chemical specications of these elements see datasheet. Verify IP rating for proper use.
This product is available on request and can be applied submerged in swimming pools and their environment. Disinfectants will have no harmful eect on the product. For chemical specications of these elements see datasheet. Verify IP rating for proper use.
Disclaimer
The published information is checked to be as accurate as possible, however Triolight B.V. or any reseller of liniLED® cannot be held liable for any damages resulting
from errors or outdated information. Triolight B.V. reserves the right to modify the information without informing the customers. When this document is printed or
downloaded, please check for the latest version on the internet, the most up to date information will be published on www.liniLED.com. This product should not
be used in applications, devices or systems where incorrect operation of the product may result in personal injury (includes emergency lighting) without written
permission from the board of Triolight B.V. If nevertheless used in such applications, devices or systems Triolight B.V. cannot be held liable for any resulting injury.
Manual | liniLED® Diuse
15
Subject to misprints, errors and modifications. No legal rights can be derived from this document. V270319
liniLED® is a registered trademark of Triolight B.V.
Loading...