LTC6087/LTC6088
5
60878fa
ELECTRICAL CHARACTERISTICS
The l denotes the specifi cations which apply over the full specifi ed
temperature range, otherwise specifi cations are at T
A
= 25°C. Test conditions are V+ = 5V, V– = 0V, VCM = 0.5V unless otherwise noted.
SYMBOL PARAMETER CONDITIONS
C SUFFIX H SUFFIX
UNITSMIN TYP MAX MIN TYP MAX
CMRR Common Mode Rejection Ratio 0V ≤ V
CM
≤ 5V
●
706884 706684 dB
dB
PSRR Power Supply Rejection Ratio VS = 2.7V to 5.5V
●
9390115 9385115 dB
dB
V
OUT
Output Voltage, High (Referred to V+) No Load
I
SOURCE
= 1mA
I
SOURCE
= 5mA
●
●
●
5
20
110
15
50
190
5
20
110
20
50
210
mV
mV
mV
Output Voltage, Low (Referred to V
–
) No Load
I
SINK
= 1mA
I
SINK
= 5mA
●
●
●
5
20
110
25
50
200
5
20
110
30
60
220
mV
mV
mV
A
VOL
Large-Signal Voltage Gain R
LOAD
= 10k, 0.5V ≤ V
OUT
≤ 4.5V
●
1000
500
6000 1000506000 V/mV
V/mV
ISC Output Short-Circuit Current Source and Sink
●
282545 282245 mA
mA
SR Slew Rate AV = 1 7.2 7.2 V/μs
GBW Gain Bandwidth Product (f
TEST
= 20kHz) R
LOAD
= 50k
●
10914 10814 MHz
MHz
Φ
0
Phase Margin RL = 10k, CL = 45pF, AV = 1 47 47 Deg
t
S
Settling Time 0.1% V
STEP
= 2V, AV = –1, RL = 1k 0.8 0.8 μs
I
S
Supply Current (per Amplifi er) No Load
●
0.85
0.80
1.05
1.05
1.25
1.30
0.85
0.75
1.05
1.05
1.25
1.40
mA
mA
Shutdown Current (per Amplifi er) Shutdown, V
SHDN
≤ 1.2V
●
2.3 5 2.3 5 μA
V
S
Supply Voltage Range Guaranteed by the PSRR Test
●
2.7 5.5 2.7 5.5 V
Channel Separation f
S
= 10kHz –120 –120 dB
Shutdown Logic SHDN High
SHDN Low
●
●
3.5
1.2
3.5
1.2
V
V
t
ON
Turn-On Time V
SHDN
= 1.2V to 3.5V 6 6 μs
t
OFF
Turn-Off Time V
SHDN
= 3.5V to 1.2V 2 2 μs
Leakage of SHDN Pin V
SHDN
= 0V
●
0.4 1 0.4 1 μA
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: A heat sink may be required to keep the junction temperature
below the absolute maximum. This depends on the power supply voltage
and the total output current.
Note 3: The LTC6087C/LTC6088C are guaranteed functional over the
operating temperature range of –40°C to 85°C. The LTC6087H/LTC6088H
are guaranteed functional over the operating temperature range of –40°C
to 125°C.
Note 4: The LTC6087C/LTC6088C are guaranteed to meet specifi ed
performance from 0°C to 70°C. The LTC6087C/LTC6088C are designed,
characterized and expected to meet specifi ed performance from –40°C to
125ºC but are not tested or QA sampled at these temperatures.
The LTC6087H/LTC6088H are guaranteed to meet specifi ed performance
from –40°C to 125°C.
Note 5: ESD (electrostatic discharge) sensitive device. ESD protection
devices are used extensively internal to the LTC6087/LTC6088; however,
high electrostatic discharge can damage or degrade the device. Use proper
ESD handling precautions.
Note 6: This parameter is not 100% tested.
Note 7: This specifi cation is limited by high speed automated test
capability. See Typical Performance Characteristic curves for actual
performance.
Note 8: Current noise is calculated from:
i
n
= √2qIB,
where q = 1.6 • 10
–19
coulombs.