Linear LTC4440, LTC3722, LT1431, LTC3901 User Manual

Description
DEMO MANUAL DC607A
LTC3722, LTC4440, LTC3901,
and LT1431
Isolated Full Bridge Converter
Demonstration circuit 607A is an isolated full bridge converter featuring the LTC3722, LTC4440, LTC3901, and LT1431. This circuit was designed to demonstrate the phase-shifted full bridge power supply to generate 12V at 35A from a typical telecom input voltage range of 36V to 72V. Isolation voltage is 1500VDC. Fixed zero-voltage
bridge leg transition times with a 48V input. The DC607A PCB layout includes options to implement adaptive timing.
Design files for this circuit board are available at
http://www.linear.com/demo/DC607A
L, LT, LTC, LTM, Linear Technology and the Linear logo are registered trademarks of Analog Devices, Inc. All other trademarks are the property of their respective owners.
transition timing was chosen because of the relatively fast
performance summary
SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS
V
IN
V
OUT
I
OUT
f
SW
V
OUT(P-P)
I
REG
P
OUT/PIN
P
OUT/PIN
Input Supply Range 36 72 V
Output Voltage 12.0 V
Output Current Range VIN = 48V, 200LFM 0 35 A
Switching (Clock) Frequency 200 kHz
Output Ripple VIN = 48V, I
Output Regulation Line and Load (36V to 72V, 0A to 35A) ±0.08 %
Efficiency VIN = 48V, I
Efficiency VIN = 48V, I
Isolation Basic 1500 VDC
Approximate Size Component Area × Top Component Height 4.3 × 2.9 × 0.4 Inches
Specifications are at TA = 25°C
= 35A (20MHz BW) 140 mV
OUT
= 35A >93.9 %
OUT
= 25A >94.6 %
OUT
P-P
operating principles
The LTC3722 synchronous dual mode phase modulated full bridge controller is used on the primary and works together with the LTC3901 secondary side synchronous driver to provide a synchronous rectified output. When an input voltage is applied, the LTC3722 begins a controlled soft-start of the output voltage. As this voltage begins to rise, the LT1431 programmable reference is quickly powered up via the output voltage. The LT1431 provides feedback via opto-coupler ISO1 to set the output voltage at 12V. The LTC4440 high voltage gate driver is used to level shift the high side primary MOSFETs gate signals.
The LTC3722 provides precise control of gate signals to primary MOSFETs and secondary MOSFETs via T3 and U1 (LTC3901). The
LTC3901 includes a timer and current
sense to limit reverse inductor current.
For large values of input inductance, a 100V, 47µF electro
­lytic capacitor can be added across the input terminals to damp the input filter and provide adequate stability. See Linear Technology Application Note 19 for a discussion on input filter stability analysis. A recommended part is the SUNCON 100ME47AX.
dc607afa
1
DEMO MANUAL DC607A
Quick start proceDure
Demonstration circuit 607A is easy to set up to evaluate the performance of the LTC3722, LTC4440, LTC3901, and LT1431. Refer to Figure 1 for proper measurement equipment setup and follow the procedure below:
NOTE. When measuring the input or output voltage ripple, care must be taken to avoid a long ground lead on the oscilloscope probe. Measure the output (or input) voltage ripple by touching the probe tip and probe ground directly across the +Vout and –Vout (or +Vin and –Vin) terminals or input/output capacitors. See Figure 2 for proper scope probe technique.
1. Set an input power supply that is capable of 36V to 72V to a voltage of 36V. Then turn off the supply.
2. With power off, connect the supply to the input terminals +Vin and –Vin.
a. Input voltages lower than 36V can keep the converter
from turning on due to the undervoltage lockout feature of the LTC3722.
b. If efficiency measurements are desired, an ammeter
capable of measuring 15Adc or a resistor shunt can be put in series with the input supply in order to measure the DC607A’s input current.
c. A voltmeter with a capability of measuring at least
can be placed across the input terminals in order
72V to get an accurate input voltage measurement.
3. Turn on the power at the input.
NOTE. Make sure that the input voltage never exceeds
72V.
4. Check for the proper output voltage of 12V ±1%. Turn off the power at the input.
5. Once the proper output voltage is established, connect a variable load capable of sinking 35A at 12V to the output terminals +Vout and –Vout. Set the current for 0A.
a. If efficiency measurements are desired, an ammeter
or a resistor shunt that is capable of handling 35Adc can be put in series with the output load in order to measure the DC607A’s output current.
b. A voltmeter with a capability of measuring at least 12V
can be placed across the output terminals in order to get an accurate output voltage measurement.
6. Turn on the power at the input.
NOTE. If there is no output, temporarily disconnect the
load to make sure that the load is not set too high.
7. Once the proper output voltage is again established, adjust the load within the operating range and observe the output voltage regulation, ripple voltage, efficiency
other desired parameters.
and
2
dc607afa
Quick start proceDure
GND
DEMO MANUAL DC607A
Figure 1. Proper Measurement Equipment Setup
VIN
Figure 2. Measuring Input or Output Ripple
dc607afa
3
DEMO MANUAL DC607A
Quick start proceDure
Figure 3. Transient Response, 0A to 35A, 48VIN (200mV and 0.5ms/Div)
4
dc607afa
Loading...