Linear 2GIG-VAR-4ROUT, 2GIG-VAR-8OUT, 2GIG-VAR-BRD Specsheet

MODULES
VARIO MAIN BOARD
Model #: 2GIG-VAR-BRD
The Vario Main Panel Board offers install flexibility with features like, selectable bell output and case tamper, for enclosure door and wall. The Easy to install plug-in BUS header saves time in wiring. Each panel provides four programmable outputs, 1 NO/NC Dry Contact Relay and 3 programmable outputs.
The Vario Main Board comes equipped with:
• 8 hardwire zones
• 4 programmable outputs
• Supports 4 wire smoke detectors with auto reset
• Internal and external tamper switches
• Barrel or terminal connections for power
• Supervised bell or speaker output
#1 most installed home control system
WORKS WITH ALL VARIO PANELS
Input Power: AC/DC Adaptor 100-240V 50/60Hz 14.4V – 1.5A, 4A
Current Consumption: 60 mA, typical / 70 mA, maximum
Rechargeable Standby Battery:
Maximum Charging Time: 24 Hours
Auxiliary Power: 1.5A PS: Total current 800mA; Maximum Aux =
Programmable Outputs: U01: Dry contact relay (24V, 1 Amps)
Main Enclosure Dimensions:
Bell/LS (External): Bell/LS (External) Sounder Output: 12 VDC @
Fuses: F1: Battery Power 3.0 A
Operating Temperature: 14°F to 131°F (-10°C to 55°C)
Storage Temperature: -4°F to 140°F (-20°C to 60°C)
Weight: 0.31lbs (0.14Kg)
1.5A PS: 12 Volts up to 7 Amp-Hours, typical
4A PS: 12 Volts up to 17 Amp-Hours, typical
500mA; Maximum BUS (AUX RED) = 800mA
4A PS: Total current 1,500mA; Maximum Aux = 500mA; Maximum BUS (AUX RED) = 800mA
Bell/LS (External): 12V DC @ 500 mA, maximum
U02-U04: 100 mA, up to relay
2GIG-VAR-BOX Polycarbonate Box
11.42” W x 10” H x 3.82” D
(290 mm x 254 mm x 97 mm)
900 mA, maximum
*: Total Current Bell+Aux = 1.5A
F2: Auxiliary Power 2.0 A F3: Bell/Loudspeaker Power 1.0 A
VARIO 8 ZONE EXPANSION BOARD
Model #: 2GIG-VAR-ZE8
Power: 13.8 VDC +/- 10%
Max Current Consumption: 25 mA, typical / 30 mA, maximum
Main Panel Connection: RS485, 4 Wire Bus, up to 984 ft. (300m) from
Auxiliary Outputs: AUX: Dry contact relay (24V, 1 Amps)
Adds an additional 8 hardwire zones to the Vario panel. Installs on the keypad BUS to accommodate remote mounting for easier wire runs. Includes an on-board tamper for installation in the 2GIG­VAR-ACCBOX.
Dimensions: 4.13” W x 2.6” H x 0.71” D
Operating Temperature: 14°F to 131°F (-10°C to 55°C)
Storage Temperature: -4°F to 140°F (-20°C to 60°C)
WORKS WITH ALL VARIO PANELS
Main Panel
(105 mm x 66 mm x 18 mm)
VARIO 8 OUTPUT EXPANDER
Model #: 2GIG-VAR-8OUT
Adds eight programmable, low current outputs for triggering devices, such as CCTV, Access Control and Building Automation systems. This output expander installs as a keypad bus device, enabling remote configuration changes of a particular output, saving potential truck rolls and the flexibility of remote mounting. Includes an on-board
tamper for installation in the 2GIG-VAR-ACCBOX.
VARIO 4 OUTPUT EXPANDER
Model #: 2GIG-VAR-4ROUT
WORKS WITH ALL VARIO PANELS
Power: 13.8 VDC +/- 10%
Max Current Consumption: 25 mA, typical / 160 mA, maximum
Main Panel Connection: RS485, 4 Wire Bus, up to 984 ft. (300m) from
Main Panel
Contacts: 4 Form C (SPDT) Relays; 5A / 24 VDC
Dimensions: 4.13” W x 2.6” H x 0.71” D
(105 mm x 66 mm x 18 mm)
Operating Temperature: 14°F to 131°F (-10°C to 55°C)
Storage Temperature: -4°F to 140°F (-20°C to 60°C)
WORKS WITH ALL VARIO PANELS
Power: 13.8 VDC +/- 10%
Max Current Consumption: 25 mA, typical / 160 mA, maximum
Main Panel Connection: RS485, 4 Wire Bus, up to 984 ft. (300m) from
Adds four programmable NO/NC dry contact relays for triggering high current loads, such as magnet locks and door strikes. This output expander installs as a keypad bus device, enabling remote
Contacts: 4 Form C (SPDT) Relays; 5A / 24 VDC
Dimensions: 4.13” W x 2.6” H x 0.71” D
configuration changes of a particular output, saving potential truck rolls and the flexibility of remote mounting. Includes an on-board
tamper for installation in the 2GIG-VAR-ACCBOX.
Operating Temperature: 14°F to 131°F (-10°C to 55°C)
Storage Temperature: -4°F to 140°F (-20°C to 60°C)
VARIO 3A SWITCHING POWER SUPPLY
Model #: 2GIG-VAR-PS3A
Power: 13.8 VDC +/- 10%
Max Current Consumption: 25 mA, typical / 160 mA, maximum
Main Panel Connection: RS485, 4 Wire Bus, up to 984 ft. (300m) from
Contacts: 4 Form C (SPDT) Relays; 5A / 24 VDC
The power supply expansion module, providing total current capacity of up to 3 Amps with extensive remote diagnostics and supervision features, including tamper protection, over-current protection, two user programmable outputs and a dedicated siren driver.
Dimensions: 4.13” W x 2.6” H x 0.71” D
Operating Temperature: 14°F to 131°F (-10°C to 55°C)
Storage Temperature: -4°F to 140°F (-20°C to 60°C)
Main Panel
(105 mm x 66 mm x 18 mm)
WORKS WITH ALL VARIO PANELS
Main Panel
(105 mm x 66 mm x 18 mm)
n Please visit 2GIG.com, or contact your local Sales Manager.
© 2016 Nortek Security & Control LLC. All Rights Reserved
P/N 1 0013 9 50X 3
1950 Camino Vida Roble, Suite 150 • Carlsbad CA 92008 • 760.438.7000 • 760.800.421.1587
nortekcontrol.com
Loading...